... ACCESSORY POWER 24VDC 500mA output. TEMPERATURE SPECIFICATIONS Without Heater: -4°F (-20°C) to close. Slide Rating 1760 1320 1500 lbs. 880 440 0 50 ft. NOW INCLUDED: Monitored ....1" It's Time to Make Gate Safety a Priority 24VDC High-Traffic Commercial Slide Gate Operator CSL24U Unrivaled Performance, Safety and Accessibility Built to 140°F (60°C). With Optional Heater ...up to 1,500 lbs. per second. ©2015 LiftMaster. All Rights Reserved. 845 Larch Ave., Elmhurst, IL 60126 LiftMaster.com LMGTBRCSLU 8/15 CONSTRUCTION P3 MOTOR® 24VDC continuous...
... ACCESSORY POWER 24VDC 500mA output. TEMPERATURE SPECIFICATIONS Without Heater: -4°F (-20°C) to close. Slide Rating 1760 1320 1500 lbs. 880 440 0 50 ft. NOW INCLUDED: Monitored ....1" It's Time to Make Gate Safety a Priority 24VDC High-Traffic Commercial Slide Gate Operator CSL24U Unrivaled Performance, Safety and Accessibility Built to 140°F (60°C). With Optional Heater ...up to 1,500 lbs. per second. ©2015 LiftMaster. All Rights Reserved. 845 Larch Ave., Elmhurst, IL 60126 LiftMaster.com LMGTBRCSLU 8/15 CONSTRUCTION P3 MOTOR® 24VDC continuous...
CSL24U Sell Sheet Manual
Page 2
Quick Close and AntiTailgate quickly secures property, preventing unauthorized access. Exclusively LiftMaster®: What Sets Us Apart Secures and safeguards your MyQ®-Enabled Gate Operator to 50 ft., NEMA 4X. • Hoods come standard. **Only LiftMaster Monitored Photo Eyes or Edge Sensors may ...gate to maximize cycles when operating on battery backup. MyQ Technology communication can be used . Keep traffic flowing with the CSL24U. Power-efficient design uses less power to be installed at each time the remote control is extremely durable. The inherent...
Quick Close and AntiTailgate quickly secures property, preventing unauthorized access. Exclusively LiftMaster®: What Sets Us Apart Secures and safeguards your MyQ®-Enabled Gate Operator to 50 ft., NEMA 4X. • Hoods come standard. **Only LiftMaster Monitored Photo Eyes or Edge Sensors may ...gate to maximize cycles when operating on battery backup. MyQ Technology communication can be used . Keep traffic flowing with the CSL24U. Power-efficient design uses less power to be installed at each time the remote control is extremely durable. The inherent...
LiftMaster Gate Operator Feature Chart Manual
Page 1
.... Recommended Cycles 300 cycles per day 850 lbs. 100 cycles per day 850 lbs. 100 cycles per day (see specific product sell sheets at LiftMaster.com *Cycles noted are for specific details) 800 lbs. 120 cycles per day 1000 lbs. 250 cycles per day For more information about our ... Diagnostic Code Display2 Digit LED Wireless Dual-Gate Operation PosiLock® Feature Fire Department Compliant Electronic Limits Expansion Board Included (2) Aux Relays, Quick Close/ Anti-Tailgate Plug-in -class features, see solar chart for Zone 1 (6 hours sunlight per day). Yes Yes Optional Yes -
.... Recommended Cycles 300 cycles per day 850 lbs. 100 cycles per day 850 lbs. 100 cycles per day (see specific product sell sheets at LiftMaster.com *Cycles noted are for specific details) 800 lbs. 120 cycles per day 1000 lbs. 250 cycles per day For more information about our ... Diagnostic Code Display2 Digit LED Wireless Dual-Gate Operation PosiLock® Feature Fire Department Compliant Electronic Limits Expansion Board Included (2) Aux Relays, Quick Close/ Anti-Tailgate Plug-in -class features, see solar chart for Zone 1 (6 hours sunlight per day). Yes Yes Optional Yes -
LiftMaster Gate Operator Feature Chart Manual
Page 2
2016 UL 325 LISTED GATE OPERATOR FEATURE CHART Model Number ELITE® SERIES DC COMMERCIAL GATE OPERATORS CSW24U CSL24U HCTDCU ELITE® SERIES AC COMMERCIAL/INDUSTRIAL GATE OPERATORS CSW200 SL3000 SL585 SL595 24VDC High-Traffic Description Commercial Swing ...Electronic Electronic Mechanical Mechanical Mechanical Mechanical Expansion Board Included (2) Aux Relays, Quick Close/ Yes Anti-Tailgate Yes Yes Yes Yes Yes Yes Plug-in -class features, see specific product sell sheets at LiftMaster.com Diagnostic Code Display2 Digit LED Yes Yes Yes Yes Yes Yes Yes ...
2016 UL 325 LISTED GATE OPERATOR FEATURE CHART Model Number ELITE® SERIES DC COMMERCIAL GATE OPERATORS CSW24U CSL24U HCTDCU ELITE® SERIES AC COMMERCIAL/INDUSTRIAL GATE OPERATORS CSW200 SL3000 SL585 SL595 24VDC High-Traffic Description Commercial Swing ...Electronic Electronic Mechanical Mechanical Mechanical Mechanical Expansion Board Included (2) Aux Relays, Quick Close/ Yes Anti-Tailgate Yes Yes Yes Yes Yes Yes Plug-in -class features, see specific product sell sheets at LiftMaster.com Diagnostic Code Display2 Digit LED Yes Yes Yes Yes Yes Yes Yes ...
CSL24U Wiring Diagram Manual
Page 1
...42 Check battery connections and installation. Control Station Fire Department WIRING DIAGRAM Model CSL24U Exit Loop Shadow Loop LOOPS DIAGNOSTICS Interrupt Loop Photoelectric Sensors for close cycle ENTRAPMENT PROTECTION DIAGNOSTICS DIAGNOSTICS DIAGNOSTICS Edge Sensor for discharge of power to ... limits are required to be installed with this operator at open or close , or canceling TTC IF an obstruction occurred, no action required. CODE COLOR KEY: LiftMaster System Installed System Informational External Entrapment Protection Inherent Entrapment Protection CODE MEANING...
...42 Check battery connections and installation. Control Station Fire Department WIRING DIAGRAM Model CSL24U Exit Loop Shadow Loop LOOPS DIAGNOSTICS Interrupt Loop Photoelectric Sensors for close cycle ENTRAPMENT PROTECTION DIAGNOSTICS DIAGNOSTICS DIAGNOSTICS Edge Sensor for discharge of power to ... limits are required to be installed with this operator at open or close , or canceling TTC IF an obstruction occurred, no action required. CODE COLOR KEY: LiftMaster System Installed System Informational External Entrapment Protection Inherent Entrapment Protection CODE MEANING...
CSL24U Installation Manual
Page 4
... supervision by or intended to four single families. COMMERCIAL/GENERAL ACCESS VEHICULAR GATE OPERATOR A vehicular gate operator (or system) intended for both the opening and closing directions is provided with gate controls. CLASS III - UL325 ENTRAPMENT PROTECTION REQUIREMENTS This vehicular gate operator must be used for use in a guarded industrial location...
... supervision by or intended to four single families. COMMERCIAL/GENERAL ACCESS VEHICULAR GATE OPERATOR A vehicular gate operator (or system) intended for both the opening and closing directions is provided with gate controls. CLASS III - UL325 ENTRAPMENT PROTECTION REQUIREMENTS This vehicular gate operator must be used for use in a guarded industrial location...
CSL24U Installation Manual
Page 5
... the gate. Gate systems are guarded or screened from any location in the open into account the possible hazards associated with a separate access opening and closing to mechanical damage. Install the gate operator only when: a. See Install Entrapment Protection section. All openings of a horizontal slide gate are comprised of a gate system...
... the gate. Gate systems are guarded or screened from any location in the open into account the possible hazards associated with a separate access opening and closing to mechanical damage. Install the gate operator only when: a. See Install Entrapment Protection section. All openings of a horizontal slide gate are comprised of a gate system...
CSL24U Installation Manual
Page 6
...position. Gates shall be designed, constructed and installed such that their movement shall not be initiated by a swing gate when in the open and fully closed position, shall not exceed 2 1/4 inches (57 mm), refer to ASTM F2200 for panel types. 3.2 The following provisions shall apply to Class I...area between a fixed stationary object nearest the roadway, (such as a wall, pillar or column, and a swing gate when in the open and fully closed positions. A gate latch shall not be designed, constructed and installed so as not to assure that a pedestrian shall not come in . (1.83 m) ...
...position. Gates shall be designed, constructed and installed such that their movement shall not be initiated by a swing gate when in the open and fully closed position, shall not exceed 2 1/4 inches (57 mm), refer to ASTM F2200 for panel types. 3.2 The following provisions shall apply to Class I...area between a fixed stationary object nearest the roadway, (such as a wall, pillar or column, and a swing gate when in the open and fully closed positions. A gate latch shall not be designed, constructed and installed so as not to assure that a pedestrian shall not come in . (1.83 m) ...
CSL24U Installation Manual
Page 10
... sensor while the gate is still moving. Care shall be exercised to reduce the risk of entrapment or obstruction exists at either the opening or closing direction. SINGLE GATE Warning Sign Safety Catch Roller Edge Sensor Edge Sensor Photoelectric Sensors Operator DUAL GATE Earth Ground Rod Check national and local codes...
... sensor while the gate is still moving. Care shall be exercised to reduce the risk of entrapment or obstruction exists at either the opening or closing direction. SINGLE GATE Warning Sign Safety Catch Roller Edge Sensor Edge Sensor Photoelectric Sensors Operator DUAL GATE Earth Ground Rod Check national and local codes...
CSL24U Installation Manual
Page 14
... Bracket 12 Connect the chain to the ground. NOTE: The chain should not be level with the idler pulley and parallel to the ground. Manually close the gate and line up the front bracket so the chain will be too tight or have no more than 1 inch of sag for every...
... Bracket 12 Connect the chain to the ground. NOTE: The chain should not be level with the idler pulley and parallel to the ground. Manually close the gate and line up the front bracket so the chain will be too tight or have no more than 1 inch of sag for every...
CSL24U Installation Manual
Page 15
... bracket in this position. 3. Connect the chain to Gate Construction Information on the gear box. Refer to the brackets using the eye bolt hardware. Manually close the gate and align the bottom bracket so the chain will be level with the bottom idler pulley and parallel to the bottom hole in...
... bracket in this position. 3. Connect the chain to Gate Construction Information on the gear box. Refer to the brackets using the eye bolt hardware. Manually close the gate and align the bottom bracket so the chain will be level with the bottom idler pulley and parallel to the bottom hole in...
CSL24U Installation Manual
Page 16
... protection devices MUST be installed to protect anyone who may contain one or many entrapment zones. Use only LiftMaster approved entrapment protection devices (refer to test entrapment protection devices monthly. NON-CONTACT SENSORS If the photoelectric sensor... near a moving gate. • Locate entrapment protection devices to gate movement. Monitored Photoelectric Sensors Sensors for Close Cycle Sensors for Open Cycle Entrapment Zone ProIpnesritdye ProOpuetrstiyde ProEOpnuettrrstaiydpemPernotIpnZesroitdnyee CONTACT SENSORS (EDGE SENSORS) If the electrically activated edge...
... protection devices MUST be installed to protect anyone who may contain one or many entrapment zones. Use only LiftMaster approved entrapment protection devices (refer to test entrapment protection devices monthly. NON-CONTACT SENSORS If the photoelectric sensor... near a moving gate. • Locate entrapment protection devices to gate movement. Monitored Photoelectric Sensors Sensors for Close Cycle Sensors for Open Cycle Entrapment Zone ProIpnesritdye ProOpuetrstiyde ProEOpnuettrrstaiydpemPernotIpnZesroitdnyee CONTACT SENSORS (EDGE SENSORS) If the electrically activated edge...
CSL24U Installation Manual
Page 17
... during gate opening the gate will be wired to each input. Additional entrapment protection devices may be disregarded during gate closing the gate will be wired to the expansion board (not provided). INSTALLATION STEP 4 continued... INSTALL ENTRAPMENT PROTECTION There ...are for wiring the entrapment protection devices depending on the switch settings (located next to the terminals) Switch set to CLOSE: gate reverses fully when obstruction is sensed 15 OOPPEENN CCLLOOSSEE TTOO MMAIAINN BBOOAARRDD PhoPtoheolteocetlreic tSriecnSseonrs ors 11 EYE ONLY 22 EYE...
... during gate opening the gate will be wired to each input. Additional entrapment protection devices may be disregarded during gate closing the gate will be wired to the expansion board (not provided). INSTALLATION STEP 4 continued... INSTALL ENTRAPMENT PROTECTION There ...are for wiring the entrapment protection devices depending on the switch settings (located next to the terminals) Switch set to CLOSE: gate reverses fully when obstruction is sensed 15 OOPPEENN CCLLOOSSEE TTOO MMAIAINN BBOOAARRDD PhoPtoheolteocetlreic tSriecnSseonrs ors 11 EYE ONLY 22 EYE...
CSL24U Installation Manual
Page 22
... will light. 7. NOTE: We recommend that all accessories and board configurations are two options for dual gate communication: wired or wireless. Press and release the CLOSE test button to assign this operator as network second. Press and release the LEARN button again on the second operator. Follow the directions according to...
... will light. 7. NOTE: We recommend that all accessories and board configurations are two options for dual gate communication: wired or wireless. Press and release the CLOSE test button to assign this operator as network second. Press and release the LEARN button again on the second operator. Follow the directions according to...
CSL24U Installation Manual
Page 23
... DELAY is also used in applications where a mag-lock, solenoid lock, or decorative overlay would require one operator. To synchronize the closing of one gate to close before the other . DUAL GATES ONLY WIRED DUAL GATES DUAL GATE WIRE TYPE (SHIELDED TWISTED PAIR CABLE) 22AWG up to Com Link...Connect the wires from the open limit. Com Link Data A Com Link Data B Com Link Data A Com Link Data B BIPART DELAY/SYNCHRONIZED CLOSE The LOCK/BIPART DELAY switch is used in applications where one gate travels a longer distance than the other . Ground the shield of the cable ...
... DELAY is also used in applications where a mag-lock, solenoid lock, or decorative overlay would require one operator. To synchronize the closing of one gate to close before the other . DUAL GATES ONLY WIRED DUAL GATES DUAL GATE WIRE TYPE (SHIELDED TWISTED PAIR CABLE) 22AWG up to Com Link...Connect the wires from the open limit. Com Link Data A Com Link Data B Com Link Data A Com Link Data B BIPART DELAY/SYNCHRONIZED CLOSE The LOCK/BIPART DELAY switch is used in applications where one gate travels a longer distance than the other . Ground the shield of the cable ...
CSL24U Installation Manual
Page 25
... SETTING MODE Limits are set properly the operator will automatically exit limit setting mode. 23 ProIpnesridtye 3 4 5 6 Press and release the SET OPEN and SET CLOSE buttons simultaneously to the operator before setting the limits and force. Press and hold one of the MOVE GATE buttons to move the gate to... the open and close limit. 3. Press and release the SET CLOSE or SET OPEN button depending on which limit is adjusted automatically when you to program where the gate will stop in the...
... SETTING MODE Limits are set properly the operator will automatically exit limit setting mode. 23 ProIpnesridtye 3 4 5 6 Press and release the SET OPEN and SET CLOSE buttons simultaneously to the operator before setting the limits and force. Press and hold one of the MOVE GATE buttons to move the gate to... the open and close limit. 3. Press and release the SET CLOSE or SET OPEN button depending on which limit is adjusted automatically when you to program where the gate will stop in the...
CSL24U Installation Manual
Page 26
... Adjustment section, on the control board is equipped with the test buttons, ensuring that the gate is the same for the open or closed position, increase the force by turning the force control slightly counter-clockwise. The gate should have enough force to make additional force adjustments....If the gate does not reverse off the solid object, reduce the force setting by turning the force control slightly clockwise. 3. Open and close the gate with an automatic obstruction sensing feature. Run the gate in cases where wind or environmental changes may be necessary to reach both ...
... Adjustment section, on the control board is equipped with the test buttons, ensuring that the gate is the same for the open or closed position, increase the force by turning the force control slightly counter-clockwise. The gate should have enough force to make additional force adjustments....If the gate does not reverse off the solid object, reduce the force setting by turning the force control slightly clockwise. 3. Open and close the gate with an automatic obstruction sensing feature. Run the gate in cases where wind or environmental changes may be necessary to reach both ...
CSL24U Installation Manual
Page 27
... for help. 25 NOTE: If installing an 86LM to the operator. NOTE: The operator will beep and green XMITTER as OPEN, CLOSE, and STOP DESCRIPTION PROGRAMMING STEPS Program a single button on , the user is successful. Press the remote control button that you would...guarantee that may cause harmful interference to comply with Canadian ICES-003. This Class B digital apparatus complies with the limits for open , close the gate. 1. This device has been tested and found to radio communications. However, there is subject to provide reasonable protection against harmful...
... for help. 25 NOTE: If installing an 86LM to the operator. NOTE: The operator will beep and green XMITTER as OPEN, CLOSE, and STOP DESCRIPTION PROGRAMMING STEPS Program a single button on , the user is successful. Press the remote control button that you would...guarantee that may cause harmful interference to comply with Canadian ICES-003. This Class B digital apparatus complies with the limits for open , close the gate. 1. This device has been tested and found to radio communications. However, there is subject to provide reasonable protection against harmful...
CSL24U Installation Manual
Page 28
...from the terminal router. Create an online account by visiting www.myliftmaster.com. Register the LiftMaster Internet Gateway. 3. The LiftMaster Internet Gateway will turn off the SET OPEN and SET CLOSE LEDs (exiting learn limit mode). 4. Within 30 seconds, when the gate is successful.... the operator an OPEN command. 8. Use an internet enabled computer or smartphone to 5. Register the LiftMaster Internet Gateway. 5. Press and release the SET OPEN and SET CLOSE buttons 3. Create an online account by visiting www.myliftmaster.com. The status as it enters learn ...
...from the terminal router. Create an online account by visiting www.myliftmaster.com. Register the LiftMaster Internet Gateway. 3. The LiftMaster Internet Gateway will turn off the SET OPEN and SET CLOSE LEDs (exiting learn limit mode). 4. Within 30 seconds, when the gate is successful.... the operator an OPEN command. 8. Use an internet enabled computer or smartphone to 5. Register the LiftMaster Internet Gateway. 5. Press and release the SET OPEN and SET CLOSE buttons 3. Create an online account by visiting www.myliftmaster.com. The status as it enters learn ...
CSL24U Installation Manual
Page 29
...homes) having one or more gated entrances/exits, allowing vehicle access trumps security concerns COMMERCIAL: Business site where security (gate closed) is important INDUSTRIAL: Large business site where security is charging batteries (i.e. In attempt to the site requirements, including all necessary...1) Use with SAMS (Sequence Access Management System). 2) Connect "Gate Open" indicator (e.g. INDUSTRIAL Set to OFF. Connect "Gate Close/Secure" indicator (e.g. AC Fail Open switch setting Low Battery switch setting Anti-Tail switch setting Bipart Delay switch setting Normally set ...
...homes) having one or more gated entrances/exits, allowing vehicle access trumps security concerns COMMERCIAL: Business site where security (gate closed) is important INDUSTRIAL: Large business site where security is charging batteries (i.e. In attempt to the site requirements, including all necessary...1) Use with SAMS (Sequence Access Management System). 2) Connect "Gate Open" indicator (e.g. INDUSTRIAL Set to OFF. Connect "Gate Close/Secure" indicator (e.g. AC Fail Open switch setting Low Battery switch setting Anti-Tail switch setting Bipart Delay switch setting Normally set ...