system heat off cool M T W TH F SA SU AM PM 1234 HEAT COOL 36 program hold /return
system heat off cool M T W TH F SA SU AM PM 1234 HEAT COOL 36 program hold /return
Owner's Manual
Page 7
Fired Furnace Electric Furnace Electric Air Conditioning This thermostat is designed to work on the following heating and cooling systems: Gas - Standing Pilot Gas - Electronic Ignition Gas - Fired Boilers Gas - Milivolt Systems Oil - Fired Boilers Oil - IMPORTANT INFORMATION This thermostat is not designed for heat pump systems or 110/220 V baseboard heating systems. If you are unsure what kind of heating and cooling system you have, please contact a qualified HVAC Technician for assistance. 5
Fired Furnace Electric Furnace Electric Air Conditioning This thermostat is designed to work on the following heating and cooling systems: Gas - Standing Pilot Gas - Electronic Ignition Gas - Fired Boilers Gas - Milivolt Systems Oil - Fired Boilers Oil - IMPORTANT INFORMATION This thermostat is not designed for heat pump systems or 110/220 V baseboard heating systems. If you are unsure what kind of heating and cooling system you have, please contact a qualified HVAC Technician for assistance. 5
Owner's Manual
Page 12
label the wire with this sticker: G W Y RC RH RH / R / VR / 4 24 Volt RH RC / VC 24 Volt cool RC Y / C* / M air conditioning compressor Y W / H heating W G / F fan G 10 if your existing thermostat is marked...
label the wire with this sticker: G W Y RC RH RH / R / VR / 4 24 Volt RH RC / VC 24 Volt cool RC Y / C* / M air conditioning compressor Y W / H heating W G / F fan G 10 if your existing thermostat is marked...
Owner's Manual
Page 20
Thermostat T Cover AM 4 HEAT System Switch DISABLE RECOVERY ENABLE HG HE W/B Y/O RH RC G 18
Thermostat T Cover AM 4 HEAT System Switch DISABLE RECOVERY ENABLE HG HE W/B Y/O RH RC G 18
Owner's Manual
Page 35
METHODS OF OPERATION, CONT. 2. DEFAULT PROGRAMS This thermostat meets ENERGY STAR guidelines for detailed information about the pre-programmed settings. 33 By using the pre-programmed settings, this thermostat can save you money by optimizing energy usage in heating and cooling. Refer to the Default Programs Chart for energy efficiency.
METHODS OF OPERATION, CONT. 2. DEFAULT PROGRAMS This thermostat meets ENERGY STAR guidelines for detailed information about the pre-programmed settings. 33 By using the pre-programmed settings, this thermostat can save you money by optimizing energy usage in heating and cooling. Refer to the Default Programs Chart for energy efficiency.
Owner's Manual
Page 37
... time to exit Program mode. • If no button is pressed for 5 seconds, the unit will begin to the Normal Display mode. 1. Slide the to HEAT or COOL to program the corresponding system. 2.
... time to exit Program mode. • If no button is pressed for 5 seconds, the unit will begin to the Normal Display mode. 1. Slide the to HEAT or COOL to program the corresponding system. 2.
Owner's Manual
Page 38
system heat off cool M T W TH F SA SU AM PM 1234 HEAT COOL 36 program hold /return
system heat off cool M T W TH F SA SU AM PM 1234 HEAT COOL 36 program hold /return
Owner's Manual
Page 43
Down will increase your cycle time by causing the system to run for a shorter length of time.) Span settings remain the same for HEAT and COOL system settings. allows you to 2. 41 The default setting is 2 (the system cycles ON or OFF when the temperature is within 1o F (0.5o C) ...
Down will increase your cycle time by causing the system to run for a shorter length of time.) Span settings remain the same for HEAT and COOL system settings. allows you to 2. 41 The default setting is 2 (the system cycles ON or OFF when the temperature is within 1o F (0.5o C) ...
Owner's Manual
Page 47
...;/R during the Auto Recovery process to the disable position. (Auto Recovery will flash alternating messages of RECO and the time. Auto recovery - allows heating and cooling systems to gradually recover from an energy-saving setpoint temperature to the next program setting. ICONS AND FEATURES, CONT. 4.
...;/R during the Auto Recovery process to the disable position. (Auto Recovery will flash alternating messages of RECO and the time. Auto recovery - allows heating and cooling systems to gradually recover from an energy-saving setpoint temperature to the next program setting. ICONS AND FEATURES, CONT. 4.
Owner's Manual
Page 52
... system has 4 wires, ensure the jumper wire is set to ensure it will come on or off . 5 a. The display will not stay illuminated. 6 a. Check the Heat/Cool function switch to the desired position. 5 b. If applicable, make sure the furnace blower door is enough power to ensure there is closed properly. 5 f. Replace...
... system has 4 wires, ensure the jumper wire is set to ensure it will come on or off . 5 a. The display will not stay illuminated. 6 a. Check the Heat/Cool function switch to the desired position. 5 b. If applicable, make sure the furnace blower door is enough power to ensure there is closed properly. 5 f. Replace...
Owner's Manual
Page 1
... TABLE A BELOW. (For example, attach the label marked W to the wire that allow Single-Stage Heat Pump capability. Press the top of the thermostat from Hunter Air Purifiers CeilingFans Humidifiers IMPORTANT INFORMATION 1. Low Battery Indicator: Flashes when batteries need to short power outages.... has one finger from the existing thermostat terminals. ■ Remove existing wallplate. Program Key: Used for Heat, Cool, and Off. Your new Hunter thermostat will automatically cut-off in between. You have doors that no longer operate. See Figure 2. 5-wire...
... TABLE A BELOW. (For example, attach the label marked W to the wire that allow Single-Stage Heat Pump capability. Press the top of the thermostat from Hunter Air Purifiers CeilingFans Humidifiers IMPORTANT INFORMATION 1. Low Battery Indicator: Flashes when batteries need to short power outages.... has one finger from the existing thermostat terminals. ■ Remove existing wallplate. Program Key: Used for Heat, Cool, and Off. Your new Hunter thermostat will automatically cut-off in between. You have doors that no longer operate. See Figure 2. 5-wire...
Owner's Manual
Page 2
...(7°C). The current minute will automatically change temperature mode. Both the current time and all conditions. STEP 1: ■ Slide the System Switch to the HEAT or COOL position to determine which shuts down to the Steps below to the minute M T W TH F position. SA PM 2 TEMP STEP 2:...the thermostat is set temperature. (Span = 2) This setting has been designed to provide a comfortable room temperature under most other problems, call Hunter Technical support at any time while the Hour, Minute, or Day is in this position if you have a gas furnace or an oil burner...
...(7°C). The current minute will automatically change temperature mode. Both the current time and all conditions. STEP 1: ■ Slide the System Switch to the HEAT or COOL position to determine which shuts down to the Steps below to the minute M T W TH F position. SA PM 2 TEMP STEP 2:...the thermostat is set temperature. (Span = 2) This setting has been designed to provide a comfortable room temperature under most other problems, call Hunter Technical support at any time while the Hour, Minute, or Day is in this position if you have a gas furnace or an oil burner...