Owner's Manual
Page 2
Call 1-800-468-1502 for the most common system We are here to help. It is Easy Label wires and remove your old thermostat Install and wire your new thermostat Set your new thermostat to match your heating/cooling system - This thermostat works with virtually all System Types - Installation is preset for wiring assistance before returning the thermostat to the store. 69-2206EF-01 ii
Call 1-800-468-1502 for the most common system We are here to help. It is Easy Label wires and remove your old thermostat Install and wire your new thermostat Set your new thermostat to match your heating/cooling system - This thermostat works with virtually all System Types - Installation is preset for wiring assistance before returning the thermostat to the store. 69-2206EF-01 ii
Owner's Manual
Page 4
If so, see back cover for proper disposal instructions. Leave wallplate in place Is there a sealed tube containing mercury? 2 Remove Old Thermostat Remove old thermostat but leave wallplate with wires attached. Old thermostat Cover 69-2206EF-01 M28099
If so, see back cover for proper disposal instructions. Leave wallplate in place Is there a sealed tube containing mercury? 2 Remove Old Thermostat Remove old thermostat but leave wallplate with wires attached. Old thermostat Cover 69-2206EF-01 M28099
Owner's Manual
Page 5
Wire Labels M28100 M28093 69-2206EF-01 3 Label Wires with Tags Label the wires using the supplied wire labels as you disconnect them.
Wire Labels M28100 M28093 69-2206EF-01 3 Label Wires with Tags Label the wires using the supplied wire labels as you disconnect them.
Owner's Manual
Page 8
Labels don't match? See pages 22-23. Call 1-800-468-1502 for wiring assistance. 69-2206EF-01 Have a Heat Pump system? We are here to help. See page 21. 6 Connect Wires Simply match wire labels. CONVENTIONAL SCREW INSERT WIRES THEN TIGHTEN SCREWS LABELED WIRES CONVENTIONAL WIRE HOLE C W2 WY G G Y2 Y W RC R R M28070 Remove metal jumper if you have both R and Rc wires.
Labels don't match? See pages 22-23. Call 1-800-468-1502 for wiring assistance. 69-2206EF-01 Have a Heat Pump system? We are here to help. See page 21. 6 Connect Wires Simply match wire labels. CONVENTIONAL SCREW INSERT WIRES THEN TIGHTEN SCREWS LABELED WIRES CONVENTIONAL WIRE HOLE C W2 WY G G Y2 Y W RC R R M28070 Remove metal jumper if you have both R and Rc wires.
Owner's Manual
Page 14
Advanced Installation System setup 13 Wiring 21 Troubleshooting 24 Customer assistance 26 Limited warranty 27
Advanced Installation System setup 13 Wiring 21 Troubleshooting 24 Customer assistance 26 Limited warranty 27
Owner's Manual
Page 15
SETUP WIRING ASybsotuetmyosuertunpew thermostat Step 1 Press System & Fan. RTH7600 0120 20 System & Fan Schedule Clock & More M27522 Step 2 Press and hold the center key until the screen changes (approximately 5 seconds). 0120 20 System Fan Done M27523 ASSISTANCE TROUBLESHOOTING 13 69-2206EF-01
SETUP WIRING ASybsotuetmyosuertunpew thermostat Step 1 Press System & Fan. RTH7600 0120 20 System & Fan Schedule Clock & More M27522 Step 2 Press and hold the center key until the screen changes (approximately 5 seconds). 0120 20 System Fan Done M27523 ASSISTANCE TROUBLESHOOTING 13 69-2206EF-01
Owner's Manual
Page 16
NOTE: Some functions in the following pages may not appear due to save & exit. SETUP WIRING Advanced Installation Guide ACbhoauntgiynogursentetwingthsermostat See pages 15-20 to change setting. Press DONE to previous selections made. Function Setting 0120 20 Go Back Next Done M27524 Press NEXT to advance to change Function Settings. Press s t to next function. ASSISTANCE TROUBLESHOOTING 69-2206EF-01 14
NOTE: Some functions in the following pages may not appear due to save & exit. SETUP WIRING Advanced Installation Guide ACbhoauntgiynogursentetwingthsermostat See pages 15-20 to change setting. Press DONE to previous selections made. Function Setting 0120 20 Go Back Next Done M27524 Press NEXT to advance to change Function Settings. Press s t to next function. ASSISTANCE TROUBLESHOOTING 69-2206EF-01 14
Owner's Manual
Page 17
... two digits) Press s/t to change the last two digits of the year: 01 - 99 (i.e., 2001 - 2099) 0140 Month Setting Press s/t to navigate between functions. SETUP WIRING RTH7600 ASybsotuetmyosuertunpew thermostat NOTE: If you set the time and date as shown on page 10, press NEXT to function 0170 and go to change the...
... two digits) Press s/t to change the last two digits of the year: 01 - 99 (i.e., 2001 - 2099) 0140 Month Setting Press s/t to navigate between functions. SETUP WIRING RTH7600 ASybsotuetmyosuertunpew thermostat NOTE: If you set the time and date as shown on page 10, press NEXT to function 0170 and go to change the...
Owner's Manual
Page 18
...heating. 8 Heat/Cool Multiple stages: 2 heat stages (wires on W and W2), 2 cooling stages (wires on Y and Y2). 9 Heat/Cool Multiple stages: 2 heat stages (wires on W and W2), 1 cooling stage (wire on Y). 10 Heat/Cool Multiple stages: 1 heat stage (wire on Y and Y2). tioning. 2 Heat pump: Heat ...tioning. 4 Heat only with fan: Gas, oil or electric heat without central air condi- ASSISTANCE TROUBLESHOOTING 69-2206EF-01 16 ing stages (wires on W), 2 cool- out backup or auxiliary heat. 3 Heat only: Gas, oil or electric heat without central air conditioning. 5 Hot ...
...heating. 8 Heat/Cool Multiple stages: 2 heat stages (wires on W and W2), 2 cooling stages (wires on Y and Y2). 9 Heat/Cool Multiple stages: 2 heat stages (wires on W and W2), 1 cooling stage (wire on Y). 10 Heat/Cool Multiple stages: 1 heat stage (wire on Y and Y2). tioning. 2 Heat pump: Heat ...tioning. 4 Heat only with fan: Gas, oil or electric heat without central air condi- ASSISTANCE TROUBLESHOOTING 69-2206EF-01 16 ing stages (wires on W), 2 cool- out backup or auxiliary heat. 3 Heat only: Gas, oil or electric heat without central air conditioning. 5 Hot ...
Owner's Manual
Page 19
SETUP WIRING ASybsotuetmyosuertunpew thermostat RTH7600 See page 14 to the O/B terminal (see page 23). ASSISTANCE TROUBLESHOOTING 17 69-2206EF-01 Function Settings & Options 0180 Heating Fan Control Press s/t to select ... whether your Changeover changeover valve is used in heating Valve (for heat or cooling: pumps only) 0 Cooling changeover valve: Use this setting if you connected a wire labeled "O" to the O/B terminal (see page 22). 1 Heating changeover valve: Use this setting if you connected...
SETUP WIRING ASybsotuetmyosuertunpew thermostat RTH7600 See page 14 to the O/B terminal (see page 23). ASSISTANCE TROUBLESHOOTING 17 69-2206EF-01 Function Settings & Options 0180 Heating Fan Control Press s/t to select ... whether your Changeover changeover valve is used in heating Valve (for heat or cooling: pumps only) 0 Cooling changeover valve: Use this setting if you connected a wire labeled "O" to the O/B terminal (see page 22). 1 Heating changeover valve: Use this setting if you connected...
Owner's Manual
Page 20
SETUP WIRING Advanced Installation Guide ASybsotuetmyosuertunpew thermostat See page 14 to select your heating Rate system: 5 Gas or oil furnace: Standard gas/oil furnace (less than 90% ...
SETUP WIRING Advanced Installation Guide ASybsotuetmyosuertunpew thermostat See page 14 to select your heating Rate system: 5 Gas or oil furnace: Standard gas/oil furnace (less than 90% ...
Owner's Manual
Page 21
... 0300 Manual/Auto Changeover Press s/t to daylight saving time (2007 and beyond, for areas that do not use the new 2007 DST calendar). SETUP WIRING ASybsotuetmyosuertunpew thermostat RTH7600 See page 14 to navigate between heat and cool settings. 0320 Temperature Press s/t to set the temperature Format (°F/°C) display format: 0 Fahrenheit 1 Celsius...
... 0300 Manual/Auto Changeover Press s/t to daylight saving time (2007 and beyond, for areas that do not use the new 2007 DST calendar). SETUP WIRING ASybsotuetmyosuertunpew thermostat RTH7600 See page 14 to navigate between heat and cool settings. 0320 Temperature Press s/t to set the temperature Format (°F/°C) display format: 0 Fahrenheit 1 Celsius...
Owner's Manual
Page 22
...: 12 12-hour clock (i.e., "3:30 pm") 24 24-hour clock (i.e., "15:30") Press DONE to navigate between functions. ASSISTANCE TROUBLESHOOTING 69-2206EF-01 20 SETUP WIRING Advanced Installation Guide ASybsotuetmyosuertunpew thermostat See page 14 to save and exit setup.
...: 12 12-hour clock (i.e., "3:30 pm") 24 24-hour clock (i.e., "15:30") Press DONE to navigate between functions. ASSISTANCE TROUBLESHOOTING 69-2206EF-01 20 SETUP WIRING Advanced Installation Guide ASybsotuetmyosuertunpew thermostat See page 14 to save and exit setup.
Owner's Manual
Page 23
...RTH7600 Alternate wiring (conventional systems) If labels do not connect them. Connect the R wire to the Rc terminal, and the RH wire to the C terminal. WIRING ASSISTANCE TROUBLESHOOTING RC Rc 2 R R 2 W W Y Y G G C C 3 Y2 Y2 W2 W2 M28076 21 69-2206EF-01 If your old thermostat had both R and Rc wires.... If your old thermostat had only 1 C or C1 wire, connect it to the R terminal. If your old thermostat had 2 C or C1 wires, wrap each separately with electrical tape and do not match terminals,...
...RTH7600 Alternate wiring (conventional systems) If labels do not connect them. Connect the R wire to the Rc terminal, and the RH wire to the C terminal. WIRING ASSISTANCE TROUBLESHOOTING RC Rc 2 R R 2 W W Y Y G G C C 3 Y2 Y2 W2 W2 M28076 21 69-2206EF-01 If your old thermostat had both R and Rc wires.... If your old thermostat had only 1 C or C1 wire, connect it to the R terminal. If your old thermostat had 2 C or C1 wires, wrap each separately with electrical tape and do not match terminals,...
Owner's Manual
Page 24
... screws. 3. If labels do not each have a wire connected, use a small piece of wire to connect them to loosen screws, insert wires into the wall opening. Use a screwdriver to each labeled wire with same letter on thermostat, see page 23. SETUP WIRING Advanced Installation Guide AWbiroiuntg-yohuerantepwumthpermostat Connect wires: Heat Pump 1. Labels don't match? If E and...
... screws. 3. If labels do not each have a wire connected, use a small piece of wire to connect them to loosen screws, insert wires into the wall opening. Use a screwdriver to each labeled wire with same letter on thermostat, see page 23. SETUP WIRING Advanced Installation Guide AWbiroiuntg-yohuerantepwumthpermostat Connect wires: Heat Pump 1. Labels don't match? If E and...
Owner's Manual
Page 25
... now and contact a qualified contractor for help . If another wire is no C wire). SETUP WIRING Wiring-heat pump RTH7600 Alternate wiring (for help . If your old thermostat had both V and VR wires, stop now and contact a qualified contractor for help. If your old thermostat had separate O and B wires, attach the B wire to the C terminal. If E and Aux terminals do...
... now and contact a qualified contractor for help . If another wire is no C wire). SETUP WIRING Wiring-heat pump RTH7600 Alternate wiring (for help . If your old thermostat had both V and VR wires, stop now and contact a qualified contractor for help. If your old thermostat had separate O and B wires, attach the B wire to the C terminal. If E and Aux terminals do...
Owner's Manual
Page 26
... in cool mode Check Function 0170: System Type to make sure it is set to match your heating and cooling equipment (see page 16). SETUP WIRING Advanced Installation Guide Troubleshooting If you have difficulty with your heating equipment (see page 17).
... in cool mode Check Function 0170: System Type to make sure it is set to match your heating and cooling equipment (see page 16). SETUP WIRING Advanced Installation Guide Troubleshooting If you have difficulty with your heating equipment (see page 17).
Owner's Manual
Page 27
... the temperature is engaged. Wait 5 minutes for the system to restart safely, without damage to Cool. mode ASSISTANCE TROUBLESHOOTING 25 69-2206EF-01 SETUP WIRING Troubleshooting RTH7600 Heating or cool- Make sure power switch at heating & cooling system is on the screen Compressor protection feature is set higher not respond than the...
... the temperature is engaged. Wait 5 minutes for the system to restart safely, without damage to Cool. mode ASSISTANCE TROUBLESHOOTING 25 69-2206EF-01 SETUP WIRING Troubleshooting RTH7600 Heating or cool- Make sure power switch at heating & cooling system is on the screen Compressor protection feature is set higher not respond than the...
Owner's Manual
Page 28
SETUP WIRING ASSISTANCE TROUBLESHOOTING 69-2206EF-01 26 Advanced Installation Guide Customer assistance For assistance with this product, please visit http://DIYthermostats.honeywell.com or call Honeywell Customer Care toll-free at 1-800-468-1502.
SETUP WIRING ASSISTANCE TROUBLESHOOTING 69-2206EF-01 26 Advanced Installation Guide Customer assistance For assistance with this product, please visit http://DIYthermostats.honeywell.com or call Honeywell Customer Care toll-free at 1-800-468-1502.
Operation Manual
Page 20
...than a month. M28419 Insert 2 fresh AA alkaline batteries 69-2207ES-05 M28420 For assistance with this product, please visit http://yourhome.honeywell.com or call Honeywell Customer Care toll-free at 1-800-468-1502. 18 Even if the warning does not appear, you should replace batteries once a ...year, or before batteries are optional (to provide backup power) if your thermostat was wired to remove from wallplate Batteries are depleted. Install...
...than a month. M28419 Insert 2 fresh AA alkaline batteries 69-2207ES-05 M28420 For assistance with this product, please visit http://yourhome.honeywell.com or call Honeywell Customer Care toll-free at 1-800-468-1502. 18 Even if the warning does not appear, you should replace batteries once a ...year, or before batteries are optional (to provide backup power) if your thermostat was wired to remove from wallplate Batteries are depleted. Install...