Configuration Guide - Page 1

MetroSelect® Area Imaging Supplemental Configuration Guide
Configuration Guide - Page 2

... contained in this manual may be liable for technical or editorial errors or omissions contained herein: nor for incidental or consequential damages resulting from the furnishing, performance, or use of International Business Machines Corporation. Web Address: www.honeywellaidc.com Trademarks Omniplanar, MetroSet2, Metrologic, MetroSelect, RangeGate, Genesis, CodeSelect, and Focus...
Configuration Guide - Page 3

... 16 Firmware Version and Address 17 Inventory Mode 18 Code Types and Decode Rules Data Matrix ...23 QR Code ...26 MaxiCode ...26 Aztec ...27 Postal ...29 Codablock Options 32 iii Table of Contents Imager Operation Presentation and Trigger Modes In-Stand...1 Out-of-Stand 2 Out-of-Stand / In-Stand Mode Match 2 Pass-Through Settings (MS7580 Only...
Configuration Guide - Page 7

... imager reverts to presentation mode 1 second after the button is released. Presentation Mode 5 seconds After Button Release ³ 8238100 The imager reverts to presentation mode when 5 seconds after the button is released. * Factory default configuration. † The term trigger and button are synonymous.  This feature is only supported in the MS7580 Genesis...
Configuration Guide - Page 9

...; ³ 8439300 Disable Pass-Through Settings In Presentation Mode ³ 127005 Enable 100 milliseconds Pass-Through Timeout ³ 8439100 * Factory default configuration for the MS7580. † The term trigger and button are synonymous.  This feature is only supported in the MS7580 Genesis.  Contact a customer service representative for information on...
Configuration Guide - Page 10

... be placed near the center of the engine's field of view indicated by the targeting dot. • When a unit is configured to operate as an omnidirectional imager, or a linear imager, or a combination of Code 128 scanner configuration labels. Enable Linear Only in Trigger Operations Disable Linear Only in Trigger Operations ³ 120213 ³ 120203 † The...
Configuration Guide - Page 16

Code Bytes 0 - 9 Notes: For additional information on Code Bytes, refer to the Code Bytes Usage section of the MetroSelect Configuration Guide (PN 00-02544). Code Byte 0 ³ 0 ³ 1 Code Byte 1 ³ 2 Code Byte 2 ³ 3 Code Byte 3 ³ 4 Code Byte 4 ³ 5 Code Byte 5 ³ 6 Code Byte 6 ³ 7 Code Byte 7 ³ 8 Code Byte 8 ³ 9 12 Code Byte ...
Configuration Guide - Page 17

... when the trigger is pulled. * Reset Same Symbol Timeout on Trigger ³ 120003 The same-symbol timeout is restarted when the trigger is only supported in the MS7580 Genesis. 13 LED Options * Normal Blue LED Intensity ³ 143100 Low Blue LED Intensity ³ 143110 * Normal White LED Intensity Low White...
Configuration Guide - Page 21

Firmware Version and Address†† Transmit the Firmware Version of the Imager with Bluetooth® Wireless Technology ³ 998044 Transmit the Address of the Imager with Bluetooth Wireless Technology ³ 998045 †† These features are not for use with the MS1690, MS1890 or the IS1650. 17
Configuration Guide - Page 23

...the Quantity 5 bar code (on page 18) has been enabled then the bar code data will be stored and transmitted once with the correct quantity after the quantity has been set to 1234 then .... If a quantity is scanned after using the quantity codes, scan the Quantity 0 bar code to replace the incorrect digits then scan the correct Quantity bar codes located on page 20 enable the user to 0300 3....
Configuration Guide - Page 32

...is disabled and the number of the same bar code (similar to CodeSelect operation). The CodeSelect timeout setting determines how much time will be allowed between ...codes with a structured append header will transmit the concatenated message once every component of the structured append bar code has been read as if a regular bar code was scanned. * Factory default configuration. 28 The imager...
Configuration Guide - Page 37

RS232 Software Handshaking Enable ]V Handshaking ³ 125210 An "]V" response from the host indicates reception of imager data. Disable ]V Handshaking ³ 125200 Multifunctional USB/IBM® Interface† Dual Interface Defaults† ³ 999923 † This feature is not for use with the MS1633. 33
Configuration Guide - Page 41

MS7580 Genesis Specific Load RS232 Configuration Settings ³ 998071 Load USB Configuration Settings ³ 998072 Load Keyboard Wedge Configuration Settings ³ 998073 Load RS485 Configuration Settings ³ 998074 Recall Configuration for Currently Connected Interface ³ 998080  This feature is only supported in the MS7580 Genesis. ...
Configuration Guide - Page 42

... Settings to All Interfaces ³ 998075 Apply Settings to RS232 Interface ³ 998076 Apply Settings to the Current Interface ³ 998081 Apply Settings to USB Interface ³ 998077 Apply Settings to Keyboard Wedge ³ 998078 Apply Settings to RS485 Interface ³ 998079  This feature is only supported in the MS7580 Genesis...
Configuration Guide - Page 48

Honeywell Scanning & Mobility 90 Coles Road Blackwood, NJ 08012-4683 00-05252 Rev B June 2009

Honeywell MK7580-30A38-00-A Reviews

Do you have an experience with the Honeywell MK7580-30A38-00-A that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Honeywell yet.

Popular Honeywell MK7580-30A38-00-A Search Terms

The following terms are frequently used to search for Honeywell MK7580-30A38-00-A support:

Ask a New Question
Use the box below to post a new question about Honeywell MK7580-30A38-00-A.
Manuals / Documents
Download any of our Honeywell MK7580-30A38-00-A manuals for free!

We have the following 1 documents available for the Honeywell MK7580-30A38-00-A:
  • Configuration Guide

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Honeywell Manuals

Find free Honeywell MK7580-30A38-00-A - MS7580 Genesis - Wired Barcode Scanner manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Honeywell Reviews
Contact Information

Complete Honeywell customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Honeywell customer service rankings, employee comments and much more from our sister site.

Honeywell Recalls

Find comprehensive Honeywell recall information updated hourly on RecallOwl.com.