HP StorageWorks MSA2012i Support and Manuals

Get Help and Manuals for this Hewlett-Packard item

View All Support Options Below
Free HP StorageWorks MSA2012i manuals!
Problems with HP StorageWorks MSA2012i?

Ask a Question

Most Recent HP StorageWorks MSA2012i Questions

Firmware For Msa1212i
Hi, where can I get the newest fw? Thanks Milan
(Posted by micy 9 years ago)

Popular HP StorageWorks MSA2012i Manual Pages

Hp StorageWorks 2000 Family Modular Smart Array CLI reference guide (481600-002, May 2008) - Page 13

...If a CSR part needs replacing, HP ships the part directly to you so that you to repair your convenience. Some parts do not qualify for worldwide technical support are listed on the HP support website: http://www.hp.com/support/. HP Technical Support Telephone numbers for CSR. Your HPauthorized service provider will determine whether a repair can install it at your HP StorageWorks product...
Hp StorageWorks 2000 Family Modular Smart Array CLI reference guide (481600-002, May 2008) - Page 125

... the WWPN, use this command to maintain storage system operation. Chapter 3 Command Descriptions 125 While troubleshooting a storage system problem, a service technician can result if fault isolation is disabled to temporarily disable fault isolation for a specific PHY exceed the built-in each I /O module containing the Expander Controller whose setting you want to enable or disable PHY...
Hp StorageWorks 2000 Family Modular Smart Array CLI reference guide (481600-002, May 2008) - Page 255

... 125. Chapter 4 Troubleshooting Using the CLI 255 Note - set expander-fault-isolation" on the chassis ear will isolate PHYs that fail to help you locate devices. This command should be used only by service technicians, or with the advice of a service technician. set expander-fault-isolation When fault isolation is disabled, the errors are noted in...
HP StorageWorks 2000 Modular Smart Array Controller Module Replacement Instructions (488318-003, April 2010) - Page 4

... Disk Arrays: http://www.hp.com/go/msa HP storage: http://www.hp.com/storage HP support: http://www.hp.com/support HP documents: http://www.hp.com/support/manuals Page 4 Verifying the firmware version After installing a controller, verify that latest version on firmware updates, see online help or the HP StorageWorks 2000 Family Modular Smart Array reference guide. For more information...
HP StorageWorks 2000 Modular Smart Array Family installation road map (488321-001, July 2008) - Page 1

... http://www.hp.com/go/services. Step 3: Install the MSA Complete installation instructions are all included in your specific product. Step 2: Develop a plan Before installing your MSA, read the user guide to use this road map Use this document is just one document in this product, HP can install it for download at http://www.hp.com/support/manuals. Complete each...
HP StorageWorks 2000 Modular Smart Array Reference Guide (481599-003, August 2008) - Page 9

Displaying Notification Events 178 Additional Status Information 179 6. Troubleshooting Using SMU 195 Problems Using SMU to a File 192 Setting Up the Debug Log 193 7. Additional Configuration Functions and Utilities 181 Updating Software 181 Disabling Partner Firmware Upgrade 183 Changing Utility Priority 183 Scanning for Device Changes 184 Resetting a Host Channel on an FC or SAS ...
HP StorageWorks 2000 Modular Smart Array Reference Guide (481599-003, August 2008) - Page 14

... Array reference guide • August 2008 Some parts do not qualify for worldwide technical support are listed on the HP support website: http://www.hp.com/support/. HP Technical Support Telephone numbers for CSR. Your HPauthorized service provider will determine whether a repair can install it at your HP StorageWorks product. If a CSR part needs replacing, HP ships the part directly to...
HP StorageWorks 2000 Modular Smart Array Reference Guide (481599-003, August 2008) - Page 162

... rack number and position of each installed disk drive. Revision of Enclosure panel shows the status and other available information about non-drive components in "Enclosure View is the bottom. ■ Firmware Version - Enclosure node World Wide Name. ■ Model - OK or error ■ Details - Enclosure location, if set . Component name and location (as current...
HP StorageWorks 2000 Modular Smart Array Reference Guide (481599-003, August 2008) - Page 165

The default is automatically upgraded. The setting can be upgraded manually. Shows whether the system can automatically take a properly sized available drive to services, user preferences... is reported and is Disabled, the host cannot modify the cache setting. Shows whether the system automatically upgrades firmware on page 80. For more information, see "Changing Utility Priority"...
HP StorageWorks 2000 Modular Smart Array Reference Guide (481599-003, August 2008) - Page 168

... or has an error. ■ Misc - The default is not installed. 168 HP StorageWorks 2000 Family Modular Smart Array reference guide • August 2008 Specifies one of the cable is healthy. ■ Error - The PHY has been disabled by a Diagnostic Manage user or by the system. ■ Non-Critical - Enclosure node World Wide Name. ■ Model - The Phy...
HP StorageWorks 2000 Modular Smart Array Reference Guide (481599-003, August 2008) - Page 241

... > General Config > Services Security. 2. Verify that the storage system's SNMP service is Enabled by default. 3. To enable SNMP in SMU As a Manage user you can manage storage devices using SNMP with a network management system such as HP System Insight Manager (SIM) or HP Instant Support Enterprise Edition (ISEE). Click Update Network Management Services. This setting is enabled; see...
HP StorageWorks 2000 Modular Smart Array Reference Guide (481599-003, August 2008) - Page 325

...in browser, 18 SES displaying firmware version, 162, 168 enabling ... configuration, 166 enabling service security, 51 SMU checking I/O status, 198 configuring event notification, 216 disk error statistics, 200 enable/..., problems after, 225 restarting a controller, 61 restoring a saved configuration file, 187 restoring default settings, 189 reverting data in -band management using to troubleshoot,...
HP 2000 Modular Smart Array Controller Firmware J202P01, J212P01, and J302P01 Release Notes (537811-008, December 2012) - Page 4

...Server 2008 W32 - Product modelsHP 2012fc Modular Smart Array (HP MSA2012fc) • HP 2212fc Modular Smart Array (HP MSA2212fc) • HP 2012i Modular Smart Array (HP MSA2012i) • HP 2012sa Modular Smart Array (HP MSA2012sa) Operating systems Operating systems supported for use with HP MSA2000 G1 Controllers (and when installing the binary firmware package): • Microsoft...
HP 2000 Modular Smart Array Controller Firmware J202P01, J212P01, and J302P01 Release Notes (537811-008, December 2012) - Page 9

...additional 15-30 minutes for the update: - CAUTION: Before upgrading firmware, ensure that the system is stable and is not being updated. ◦ Create a full backup of low I /O load can impact the upgrade process. If Partner Firmware Update is performed while host I /O must manually update the second controller. • During the installation process: ◦ Monitor the system display...
HP StorageWorks 2012i Modular Smart Array user guide (481598-003, March 2013) - Page 9

... HP StorageWorks product warranties, see the CSR website: http://www.hp.com/go /storagewarranty About This Guide 9 Although the term is no longer used. If a CSR part needs replacing, HP ships the part directly to related documents, media, and user interfaces use the term. HP Technical Support Telephone numbers for CSR. Your HPauthorized service provider will determine whether a repair...

HP StorageWorks MSA2012i Reviews

Do you have an experience with the HP StorageWorks MSA2012i that you would like to share?
Earn 750 points for your review!
We have not received any reviews for HP yet.

Popular HP StorageWorks MSA2012i Search Terms

The following terms are frequently used to search for HP StorageWorks MSA2012i support:

Ask a New Question
Use the box below to post a new question about HP StorageWorks MSA2012i.
Manuals / Documents
Download any of our HP StorageWorks MSA2012i manuals for free!

We have the following 10 documents available for the HP StorageWorks MSA2012i:
  • HP StorageWorks 2000 Modular Smart Array Reference Guide (481599-003, August 2008)
  • Hp StorageWorks 2000 Family Modular Smart Array CLI reference guide (481600-002, May 2008)
  • HP StorageWorks 2012i Modular Smart Array user guide (481598-003, March 2013)
  • HP 2000 Modular Smart Array Controller Firmware J202P01, J212P01, and J302P01 Release Notes (537811-008, December 2012)
  • HP StorageWorks 2000 Family Modular Smart Array chassis and midplane replacement instructions (481596-001, March 2008)
  • HP StorageWorks 2000 Modular Smart Array Controller Module Replacement Instructions (488318-003, April 2010)
  • HP MSA2000 I/O Module Replacement Instructions (481609-002, October 2012)
  • HP StorageWorks 2000 Modular Smart Array Family installation road map (488321-001, July 2008)
  • HP StorageWorks 2000 Modular Smart Array racking instructions (494159-001, July 2008)
  • HP StorageWorks 2012i Modular Smart Array controller module replacement instructions (481594-001, March 2008)

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

HP Manuals

Find free HP StorageWorks MSA2012i manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

HP Reviews

View thousands of HP StorageWorks MSA2012i user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete HP customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed HP customer service rankings, employee comments and much more from our sister site.

HP Recalls

Find comprehensive HP recall information updated hourly on RecallOwl.com.