Sun Solaris 10 Deployment Guide for HP ProLiant Servers
Page 7
...guidance on selecting a strategy based on various environmental requirements, see "Deployment planning." ○ For information on ProLiant servers, see "Architecture of an installation" and "Deploying ProLiant servers." ○ For information about these guidelines: • For interactive installations using the Solaris media, see "...), at http://docs.sun.com/app/docs/doc/819-6398 Introduction 7 Table 1 Applicable HP ProLiant servers BL280c G6 DL320 G5p DL320 G6 Using this guide For effective use of this guide, follow these topics, see "Architecture of an installation."
...guidance on selecting a strategy based on various environmental requirements, see "Deployment planning." ○ For information on ProLiant servers, see "Architecture of an installation" and "Deploying ProLiant servers." ○ For information about these guidelines: • For interactive installations using the Solaris media, see "...), at http://docs.sun.com/app/docs/doc/819-6398 Introduction 7 Table 1 Applicable HP ProLiant servers BL280c G6 DL320 G5p DL320 G6 Using this guide For effective use of this guide, follow these topics, see "Architecture of an installation."
Sun Solaris 10 Deployment Guide for HP ProLiant Servers
Page 39
... the SATA controller is complete and the system has rebooted, run sys-unconfig(1M). HP ProLiant BL260c G5, BL280c G6 • Description-Cannot install SUN Solaris 10 operating system on an HP ProLiant BL260c G5 or BL280c G6 blade server when the SATA controller is a known issue with Solaris 10 10/08. Kernel Panic after rebooting. After the installation...
... the SATA controller is complete and the system has rebooted, run sys-unconfig(1M). HP ProLiant BL260c G5, BL280c G6 • Description-Cannot install SUN Solaris 10 operating system on an HP ProLiant BL260c G5 or BL280c G6 blade server when the SATA controller is a known issue with Solaris 10 10/08. Kernel Panic after rebooting. After the installation...
Sun Solaris 10 Deployment Guide for HP ProLiant Servers
Page 42
... the above steps after CPQary3 added to the miniroot. Embedded Ethernet not configured • OS Releases affected-Solaris 10 5/08, 10/08, 6/09 • Servers affected-HP ProLiant BL280c G6 • Description-There is added to Miniroot • OS Releases affected-Solaris 10 5/09 • Description-"Add_drv/Rem_drv Currently Busy; Proceed with the installation. Alternately...
... the above steps after CPQary3 added to the miniroot. Embedded Ethernet not configured • OS Releases affected-Solaris 10 5/08, 10/08, 6/09 • Servers affected-HP ProLiant BL280c G6 • Description-There is added to Miniroot • OS Releases affected-Solaris 10 5/09 • Description-"Add_drv/Rem_drv Currently Busy; Proceed with the installation. Alternately...
HP ProLiant BL280c G6 Server Blade Maintenance and Service Guide
Page 60
For more information, see the HP ProLiant BL280c G6 Server Blade Installation Instructions that ship with blank) 17 Processor socket 1 (populated) The symbols correspond to x8 speeds. System board components Item Description 1 Processor 1 DIMMs (6) 2...card Component identification 60 Item Mezzanine connector 1 Mezzanine connector 2 PCIe x8, Type I ) 14 Embedded NICs (2) 15 TPM connector 16 Processor socket 2 (with the server blade. Mezzanine connector definitions A PCIe x8 mezzanine connector supports x16 cards at up to the symbols located on the interconnect bays.
For more information, see the HP ProLiant BL280c G6 Server Blade Installation Instructions that ship with blank) 17 Processor socket 1 (populated) The symbols correspond to x8 speeds. System board components Item Description 1 Processor 1 DIMMs (6) 2...card Component identification 60 Item Mezzanine connector 1 Mezzanine connector 2 PCIe x8, Type I ) 14 Embedded NICs (2) 15 TPM connector 16 Processor socket 2 (with the server blade. Mezzanine connector definitions A PCIe x8 mezzanine connector supports x16 cards at up to the symbols located on the interconnect bays.
HP ProLiant BL280c G6 Server Blade User Guide
Page 9
... the interconnect bays. Item Mezzanine connector 1 Mezzanine connector 2 PCIe x8, Type I ) 14 Embedded NICs (2) 15 TPM connector 16 Processor socket 2 (with the server blade. For more information, see the HP ProLiant BL280c G6 Server Blade Installation Instructions that ship with blank) 17 Processor socket 1 (populated) The symbols correspond to x8 speeds. System board components Item Description...
... the interconnect bays. Item Mezzanine connector 1 Mezzanine connector 2 PCIe x8, Type I ) 14 Embedded NICs (2) 15 TPM connector 16 Processor socket 2 (with the server blade. For more information, see the HP ProLiant BL280c G6 Server Blade Installation Instructions that ship with blank) 17 Processor socket 1 (populated) The symbols correspond to x8 speeds. System board components Item Description...
HP ProLiant BL280c G6 Server Blade User Guide
Page 22
...hardware damage. SAS hard drives are stored on page 15). 5. The HP Smart Array P712m Controller option does not support hard drive activity LEDs when installed in the HP ProLiant BL280c G6 Server Blade. Install the hard drives. Hardware options installation Introduction If more ...allow the drives and the internal system components to electrical components, properly ground the server before touching them. CAUTION: Failure to streamline the installation process. Hard drive option The HP ProLiant BL280c G6 Server Blade supports midline SATA hard drives and 9.5-mm SATA hard drives.
...hardware damage. SAS hard drives are stored on page 15). 5. The HP Smart Array P712m Controller option does not support hard drive activity LEDs when installed in the HP ProLiant BL280c G6 Server Blade. Install the hard drives. Hardware options installation Introduction If more ...allow the drives and the internal system components to electrical components, properly ground the server before touching them. CAUTION: Failure to streamline the installation process. Hard drive option The HP ProLiant BL280c G6 Server Blade supports midline SATA hard drives and 9.5-mm SATA hard drives.
HP ProLiant BL280c G6 Server Blade User Guide
Page 38
...cards only on page 15). 4. For mezzanine card locations, see "Interconnect bay numbering and device mapping (on page 9). For mezzanine card mapping, see the HP ProLiant BL280c G6 Server Blade Installation Instructions or see the system board components (on page 18)." Remove the access panel (on page 15). 6. Remove the air baffle (on ... 14). 3. Remove the access panel (on mezzanine 2 connector. To install the component: 1. The card type determines where it can be installed in RBSU ("HP ROMBased Setup Utility" on page 15). 10. 3. Power down the server blade (on page 13). 2.
...cards only on page 15). 4. For mezzanine card locations, see "Interconnect bay numbering and device mapping (on page 9). For mezzanine card mapping, see the HP ProLiant BL280c G6 Server Blade Installation Instructions or see the system board components (on page 18)." Remove the access panel (on page 15). 6. Remove the air baffle (on ... 14). 3. Remove the access panel (on mezzanine 2 connector. To install the component: 1. The card type determines where it can be installed in RBSU ("HP ROMBased Setup Utility" on page 15). 10. 3. Power down the server blade (on page 13). 2.
HP ProLiant BL280c G6 Server Blade User Guide
Page 40
... SAS hard drives in the HP ProLiant BL280c G6 Server Blade. To install the component: 1. If installed, disconnect the hard drive power and data cables from each hard drive bay. Installing the long hard drive screws, located on page 15). 6. The HP Smart Array P712m Controller option ...(on page 14). 3. Hardware options installation 40 Do one of personal injury from each hard drive bay. Remove the server blade (on page 15). 4. Item 1 2 3 4 5 6 7 8 Description HP Smart Array P712m Controller SAS connector 2 SAS connector 1 Hard drive 2 Hard drive connector 2 Hard drive connector 1 ...
... SAS hard drives in the HP ProLiant BL280c G6 Server Blade. To install the component: 1. If installed, disconnect the hard drive power and data cables from each hard drive bay. Installing the long hard drive screws, located on page 15). 6. The HP Smart Array P712m Controller option ...(on page 14). 3. Hardware options installation 40 Do one of personal injury from each hard drive bay. Remove the server blade (on page 15). 4. Item 1 2 3 4 5 6 7 8 Description HP Smart Array P712m Controller SAS connector 2 SAS connector 1 Hard drive 2 Hard drive connector 2 Hard drive connector 1 ...