Sun Solaris 10 Deployment Guide for HP ProLiant Servers
Page 4
... disks with DiskSuite ...36 Troubleshooting ...38 Known issues...38 Write cache not flushed on shutdown...38 Solaris stops responding on HP ProLiant DL580 G5 server 38 RAID mode not supported ...39 Kernel Panic after disabling PCI devices in RBSU 39 Network configuration fails during interactive...SNMP master agent ...40 bcme fails to attach ...41 System panics and reboots during installation 42 Embedded Ethernet not configured ...42 Hard Drives not seen after CPQary3 added to Miniroot 42 Basic troubleshooting techniques ...43 Shell prompt ...43 Network verification ...43 GRUB command line...
... disks with DiskSuite ...36 Troubleshooting ...38 Known issues...38 Write cache not flushed on shutdown...38 Solaris stops responding on HP ProLiant DL580 G5 server 38 RAID mode not supported ...39 Kernel Panic after disabling PCI devices in RBSU 39 Network configuration fails during interactive...SNMP master agent ...40 bcme fails to attach ...41 System panics and reboots during installation 42 Embedded Ethernet not configured ...42 Hard Drives not seen after CPQary3 added to Miniroot 42 Basic troubleshooting techniques ...43 Shell prompt ...43 Network verification ...43 GRUB command line...
Sun Solaris 10 Deployment Guide for HP ProLiant Servers
Page 38
... the list of the known issues apply, see "Basic troubleshooting techniques." Drive Array Reports Valid Data Found in slots 1, 2, 4, 5, 7, or 8. Write cache not flushed on shutdown Solaris does not flush hard drive controller cache to see if any issues match the environment and symptoms. ... command before every shutdown: # swap -d Optionally, shutdown the system using these commands: # init 0 # halt Solaris stops responding on HP ProLiant DL580 G5 server Solaris may stop responding, or will not respond properly during deployment if a PCI-Express Controller, such as a Smart Array P800 is...
... the list of the known issues apply, see "Basic troubleshooting techniques." Drive Array Reports Valid Data Found in slots 1, 2, 4, 5, 7, or 8. Write cache not flushed on shutdown Solaris does not flush hard drive controller cache to see if any issues match the environment and symptoms. ... command before every shutdown: # swap -d Optionally, shutdown the system using these commands: # init 0 # halt Solaris stops responding on HP ProLiant DL580 G5 server Solaris may stop responding, or will not respond properly during deployment if a PCI-Express Controller, such as a Smart Array P800 is...