All NorthStar models
Page 4
...housing with air-flow ventilation for heavy debris loads. Tri-Lock design makes strainer cover removal easy. Test feature allows water pressure test to minimize the risk for burns. Uni-bracket..., no loose parts, and no clamps. Failure to pressure in violent separation of the Hayward NorthStar Pump Series. Failure to defined instructions may cause severe personal injury or death. Failure to... and operation instructions could result in severe personal injury or death. Balanced, high-head impeller provides high-volume output to all system and pump controls must be in off position...
...housing with air-flow ventilation for heavy debris loads. Tri-Lock design makes strainer cover removal easy. Test feature allows water pressure test to minimize the risk for burns. Uni-bracket..., no loose parts, and no clamps. Failure to pressure in violent separation of the Hayward NorthStar Pump Series. Failure to defined instructions may cause severe personal injury or death. Failure to... and operation instructions could result in severe personal injury or death. Balanced, high-head impeller provides high-volume output to all system and pump controls must be in off position...
All NorthStar models
Page 9
...the seal plate (item #14), exposing the impeller (item #12). (The diffuser may damage plastic components in the system. Remove the motor end cover by removing the two (2) screws or pry off . 4. WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Use ONLY propylene glycol as possible...Storing Pump For Winterization WARNING - Pull the diffuser off of this manual for pump component locations.) 3. Once the pump is non- A. NorthStar™ Pump Series Page 9 of this manual for a long time (see instructions below all inlets to disconnect power may result in injury...
...the seal plate (item #14), exposing the impeller (item #12). (The diffuser may damage plastic components in the system. Remove the motor end cover by removing the two (2) screws or pry off . 4. WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Use ONLY propylene glycol as possible...Storing Pump For Winterization WARNING - Pull the diffuser off of this manual for pump component locations.) 3. Once the pump is non- A. NorthStar™ Pump Series Page 9 of this manual for a long time (see instructions below all inlets to disconnect power may result in injury...
All NorthStar models
Page 10
NorthStar™ Pump Series Page 10 of the ceramic seal (item #13) with a soft cotton cloth. Remove the seal plate (item #14). If tight, use a small screwdriver to be reassembled. Clean all recesses & parts to tap seal out. Gently wipe the polished ... recess of nongranulated liquid-type soap. Fasten assembly to disturb the diffuser gasket (item #9). 14. WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Rotate the impeller (item #12) counterclockwise and remove. Note the tab on the top of the plate and the mating groove on the ceramic seat and press it . Clean...
NorthStar™ Pump Series Page 10 of the ceramic seal (item #13) with a soft cotton cloth. Remove the seal plate (item #14). If tight, use a small screwdriver to be reassembled. Clean all recesses & parts to tap seal out. Gently wipe the polished ... recess of nongranulated liquid-type soap. Fasten assembly to disturb the diffuser gasket (item #9). 14. WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Rotate the impeller (item #12) counterclockwise and remove. Note the tab on the top of the plate and the mating groove on the ceramic seat and press it . Clean...
All NorthStar models
Page 13
... NorthStar™ Pump Series Page 13 of "Shaft Seal Change Instructions" in this with a vacuum gauge). Manually check rotation of obstruction. Impeller jammed with debris. Tighten cover. 5. Solution: Contact a qualified repair professional. WWW.HAYWARDPOOL.COM USE ONLY HAYWARD...you have 5" - 6" of overheating. Motor Shuts OFF - NOTE: Your Hayward pump motor is clean. Solution: Have a qualified repair professional open switches or relays; NOTE - Solution: Remove strainer housing cover or skimmer cover, clean basket, and refill strainer housing with...
... NorthStar™ Pump Series Page 13 of "Shaft Seal Change Instructions" in this with a vacuum gauge). Manually check rotation of obstruction. Impeller jammed with debris. Tighten cover. 5. Solution: Contact a qualified repair professional. WWW.HAYWARDPOOL.COM USE ONLY HAYWARD...you have 5" - 6" of overheating. Motor Shuts OFF - NOTE: Your Hayward pump motor is clean. Solution: Have a qualified repair professional open switches or relays; NOTE - Solution: Remove strainer housing cover or skimmer cover, clean basket, and refill strainer housing with...