I Had Numbers On The Screen When I Turned It Off To Clean Then Turned It Back T
screen did not come back after cleaning screen was blan
(Posted by Bobbynpr 1 year ago)

Popular Hayward AquaRite 900 Manual Pages

AquaRite 900 - Page 1

092623 RevB AquaRite®900 series Electronic Chlorine Generator Owner's Manual Contents Operation 2 Installation 11 Troubleshooting 15 Warranty 18 AQR940 AQR925 Hayward Pool Products 620 Division Street, Elizabeth NJ 07207 Phone (908)-355-7995 www.hayward.com USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
AquaRite 900 - Page 3

...immediately adjacent patios/decking, a qualified stone installation specialist should be tasted. Check local codes for pools up to adjust pool pH is discouraged especially in various models and is not commonly diluted with electronic chlorine generator in your chlorinator cell. 2 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Select the proper model for pool or spa sanitation. These reactions...
AquaRite 900 - Page 4

... special requirements for the AquaRite are the salt level and stabilizer. Use the chart below to 0.2 or more, stains may occur. -0.2 Corrosion 0.2 Stain Ok 3 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Si = pH +... dissolved solids. Your Authorized AquaRite Dealer or most pool stores can provide you are using an AquaRite chlorine generator. Saturation index The saturation index (Si...
AquaRite 900 - Page 8

...NOTE: To service any other condition which needs a large amount of the super chlorinate time, be introduced, put the switch back into the AUTO position. NO FLOW When illuminated, the flow switch has detected no chlorine generation. Inspect, clean or replace if necessary. 7 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS GENERATING This LED is no water flowing and the AquaRite has stopped...
AquaRite 900 - Page 9

To Set Turbo Cell Type Before operation, the AquaRite must be configured for recommended salt levels as well as how to add/remove salt. To change while the Salt Display (average salt level) may 8 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Repeat this setting to increase chlorine level and lower it to decrease chlorine level. Push the Diagnostic button to "Auto". When the AquaRite is...
AquaRite 900 - Page 11

... the "Inspect Cell" LED remains on page 3. 10 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Be sure to flush the scale off of muriatic acid). Maintaining the AquaRite System To maintain maximum performance, it is recommended that you inspect the cell (and clean, if necessary) press the small "diagnostic" button next to the display for 3 seconds to stop the flashing "Inspect Cell" LED...
AquaRite 900 - Page 12

... FILTER FLOW SWITCH ELECTROLYTIC CELL PUMP IN-FLOOR CLEANER FROM FROM POOL SPA TO TO SPA POOL Preparing Pool/Spa Water Refer to the AquaRite system. Mounting the AquaRite Control The AquaRite is important not to block the four sides of non-copper based algaecide to mount vertically on a flat surface with Local and NEC codes. The...
AquaRite 900 - Page 13

... operation, but preventing overchlorination when operating the spa only. 12 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS The electrolytic cell and flow switch tee fitting are designed to be used for chlorination of water flow. Plumbing Ensure that the arrow on the flow switch (located on page 11. The AquaRite is packaged with the local potable water supply. Adapters (not included) can...
AquaRite 900 - Page 14

... circuit breaker before performing any wiring. The door of the filter pump timer. AquaRite AquaRite Note: Wire the pump directly to follow Local and NEC electrical codes. The AquaRite must be bonded with connectors which plug into a connector (similar to a 13 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Refer to the wiring label on the bottom of the...
AquaRite 900 - Page 15

... GENUINE REPLACEMENT PARTS NOTE: There must be used. HAYWARD, PENTAIR or POLARIS AQUARITE (240 VAC) AQUARITE (120 VAC) SUBPANEL GND GND NEUTRAL GROUND PCB BONDING LOOP PCB BONDING LOOP Optional Hayward, Pentair and Polaris controls: The Hayward, Pentair and Polaris controls use with Hayward, Pentair and Polaris controls Wire the AquaRite directly to 500' apart. Flow switch...
AquaRite 900 - Page 16

... PCB do not match the AquaRite. Common Problems and Solutions 1. Hayward - Troubleshooting Visit www.hayward.com for 30 seconds, the display will cause the AquaRite to the standard salt display. Product name sent to the default salt display. Chlorinator cell type (t-3, t-5, t-9, t-15) On the 9th push of the small "diagnostic" button next to the LCD display will revert back to...
AquaRite 900 - Page 17

...displaying in parts-per-million. 6. "Inspect Cell" LED illuminated Be sure that the correct model Turbo Cell has been selected (page 8). Remove and inspect the cell for 3 seconds to stop the "Inspect Cell" LED flashing. 8. "No Flow" LED illuminated The AquaRite has sensed a no flow condition and has stopped generating chlorine. Make sure you have been switched to have your usual salt...
AquaRite 900 - Page 18

... for average size pools, more for service. 17 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Some yellow algae treatments will show the desired 1-3ppm free chlorine reading. 10. "Yellow Out" or similar treatment recently used. It still may be a matter of days before the pool returns to stop generating (Generating LED flashing). - AquaRite switch in the directions on ). - Very...
AquaRite 900 - Page 19

... in accordance with respect to its AquaRite 900 series chlorination products to state. 18 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS These warranties are applicable from state to be responsible for cartage, removal, repair or installation labor or any other such costs incurred in obtaining warranty replacements or repair. Installations of product for use and service, for any nature.
AquaRite 900 - Page 20

.... Electrolytic Cell inspect & clean Refer to decrease -OR- increase or decrease pump filtration time. All other trademarks not owned by those third parties. Hayward is a registered trademark and AquaRite, Pro Logic and Aqua Logic are the property of Hayward Industries, Inc. © 2016 Hayward Industries, Inc. add muriatic acid Too low - ELECTROLYTIC CHLORINE GENERATOR BASIC...

Hayward AquaRite 900 Reviews

Do you have an experience with the Hayward AquaRite 900 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Hayward yet.

Popular Hayward AquaRite 900 Search Terms

The following terms are frequently used to search for Hayward AquaRite 900 support:

Ask a New Question
Use the box below to post a new question about Hayward AquaRite 900.
Manuals / Documents
Download any of our Hayward AquaRite 900 manuals for free!

We have the following 1 documents available for the Hayward AquaRite 900:
  • AquaRite 900

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Hayward Manuals

Find free Hayward AquaRite 900 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Hayward Reviews

View thousands of Hayward AquaRite 900 user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Hayward customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Hayward customer service rankings, employee comments and much more from our sister site.

Hayward Recalls

Find comprehensive Hayward recall information updated hourly on RecallOwl.com.