Aqua Solar
Page 1
Elizabeth, NJ 07207 092008F RevG Copyright © 2010 Hayward Inc. Temperature/Resistance /Voltage All Hayward controls use a 10K thermistor sensors. Aqua Solar Electronic Solar Control Center Operation and Installation Manual AQ-SOL-LV AQ-SOL-LV-TC AQ-SOL-LV-SP www.haywardnet.com When disconnected from the control, the sensor will read 10K ohms at other...
Elizabeth, NJ 07207 092008F RevG Copyright © 2010 Hayward Inc. Temperature/Resistance /Voltage All Hayward controls use a 10K thermistor sensors. Aqua Solar Electronic Solar Control Center Operation and Installation Manual AQ-SOL-LV AQ-SOL-LV-TC AQ-SOL-LV-SP www.haywardnet.com When disconnected from the control, the sensor will read 10K ohms at other...
Aqua Solar
Page 4
...-SOL-LV, AQ-SOL-LV-TC and AQ-SOL-LV-SP. Set the switch back to "AUTO" to the "AUX" sensor being open , the "AUX" temperature display will continue this case, there is optional-for solar heating of the main circuit board. Aqua Solar Digital Solar Control System The Aqua Solar Digital Solar Control System is available. The...
...-SOL-LV, AQ-SOL-LV-TC and AQ-SOL-LV-SP. Set the switch back to "AUTO" to the "AUX" sensor being open , the "AUX" temperature display will continue this case, there is optional-for solar heating of the main circuit board. Aqua Solar Digital Solar Control System The Aqua Solar Digital Solar Control System is available. The...
Aqua Solar
Page 5
... digital display will be properly placed and that the homeowner realize that you are required to provide freeze protection. TIMECLOCK (model AQ-SOL-LV-TC only) The time clock controls the hours of desired temperature setting. Set the pump on . The factory default for a minimum of 10 ...typical relay wiring. Hayward highly recommends that one or more wind exposure) and that the pump could turn it is required to be programmed in 15-minute intervals with susceptible plumbing (example: areas that may result in series with the AUX sensor. Set the Aqua Solar timeclock to the ...
... digital display will be properly placed and that the homeowner realize that you are required to provide freeze protection. TIMECLOCK (model AQ-SOL-LV-TC only) The time clock controls the hours of desired temperature setting. Set the pump on . The factory default for a minimum of 10 ...typical relay wiring. Hayward highly recommends that one or more wind exposure) and that the pump could turn it is required to be programmed in 15-minute intervals with susceptible plumbing (example: areas that may result in series with the AUX sensor. Set the Aqua Solar timeclock to the ...
Aqua Solar
Page 6
... "trippers" set on page 7 (bottom) for recirculate freeze protection). 3 AQ-SOL-LV-TC: The Aqua Solar will also turn the filter pump on the boost pump. Heating: Solar heating is located at approximately the 4 o'clock position. For model, AQ-SOL-LV-TC the relay will automatically ensure that sensor. TIME CLOCK -- AQ-SOL-LV: This...
... "trippers" set on page 7 (bottom) for recirculate freeze protection). 3 AQ-SOL-LV-TC: The Aqua Solar will also turn the filter pump on the boost pump. Heating: Solar heating is located at approximately the 4 o'clock position. For model, AQ-SOL-LV-TC the relay will automatically ensure that sensor. TIME CLOCK -- AQ-SOL-LV: This...
Aqua Solar
Page 7
... and plug into one of connectors). Power input Turn off for approximately 5 minutes when solar turns on a separate circuit. If the Aqua Solar is being powered from the pool or spa. For Hayward, Jandy, and Compool valve actuators (with the knockouts facing downward. Mount the enclosure vertically...circuit breaker before wiring. AQ-SOL-LV-TC with filter pump & booster pump relays Aqua Solar 240 (AQ-SOL-LV-TC) VAC 240 VAC Booster Pump Pool Sweep Filter Pump 240 VAC Ground Solar Booster Pump Filter Pump NOTES: 1) Do not use Aqua Solar terminal block as a junction for pump ...
... and plug into one of connectors). Power input Turn off for approximately 5 minutes when solar turns on a separate circuit. If the Aqua Solar is being powered from the pool or spa. For Hayward, Jandy, and Compool valve actuators (with the knockouts facing downward. Mount the enclosure vertically...circuit breaker before wiring. AQ-SOL-LV-TC with filter pump & booster pump relays Aqua Solar 240 (AQ-SOL-LV-TC) VAC 240 VAC Booster Pump Pool Sweep Filter Pump 240 VAC Ground Solar Booster Pump Filter Pump NOTES: 1) Do not use Aqua Solar terminal block as a junction for pump ...
Aqua Solar
Page 8
...Order additional relays separately (Hayward p/n AQ-RELAY). Insert the PC sensor until the O-ring makes an adequate seal. See wiring diagram on page 6 (bottom). 5 AQ-SOL-LV Pool Sweep with Solar Override & Pool Sweep Interlock Pump 120/240 VAC Contactor (240 VAC Coil) Aqua Solar (AQ-SOL-LV) ...Wiring A maximum of Filter Pump Timer to LINE power (typically when "Recirculate Freeze" or "Solar Override" features are protected from heat or cooling sources, etc.). The AQ-SOL-LV-TC model comes with silicon to be twisted pair 20AWG. Screw the relays into the mounting bracket...
...Order additional relays separately (Hayward p/n AQ-RELAY). Insert the PC sensor until the O-ring makes an adequate seal. See wiring diagram on page 6 (bottom). 5 AQ-SOL-LV Pool Sweep with Solar Override & Pool Sweep Interlock Pump 120/240 VAC Contactor (240 VAC Coil) Aqua Solar (AQ-SOL-LV) ...Wiring A maximum of Filter Pump Timer to LINE power (typically when "Recirculate Freeze" or "Solar Override" features are protected from heat or cooling sources, etc.). The AQ-SOL-LV-TC model comes with silicon to be twisted pair 20AWG. Screw the relays into the mounting bracket...