Haier HSU18VH7-W - Ductless Split Outdoor Unit Heat Pump Support and Manuals

Get Help and Manuals for this Haier item

View All Support Options Below
Free Haier HSU18VH7-W manuals!
Problems with Haier HSU18VH7-W?

Ask a Question

Most Recent Haier HSU18VH7-W Questions

Hsu18vck Compressor
What type of compressor is it? Recip, rotary, scroll or what?
(Posted by engphys57 11 years ago)

Popular Haier HSU18VH7-W Manual Pages

Service Manual - Page 1

HSU18VH7 THIS MANUAL IS USED BY QUALIFIED APPLIANCE TECHNICIANS ONLY. HAIER DOES NOT ASSUME ANY RESPONSIBILITY FOR PROPERTY DAMAGE OR PERSONAL INJURY FOR IMPROPER SERVICE PROCEDURES DONE BY ONE UNQUALIFIED PERSON. Air conditioner Edition: 10070808 Domestic Air conditioner CAUTION READ THIS MANUAL CAREFULLY TO DIAGNOSE TROUBLE CORRECTLY BEFORE OFFERING SERVICE.
Service Manual - Page 2

ELECTRICAL CONTROLS 4 4. WIRING DIAGRAM 20 7. SPECIFICATION 3 3. COMPRESSOR PERFORMANCE DIAGRAM 24 9. SCHEMATIC DIAGRAM OF PCB 25 TROUBLE SHOOTING 10 5. Air conditioner Edition: 10070808 CONTENTS 1. INSTALLA TION 12 6. THERMISTOR RESISTANCE CHART 22 8. GENERAL INFORMATION 1 2.
Service Manual - Page 3

... with safety information may cause death or severe illness, air conditioner must be monitored when malfunctions or shuts down. ! If a two-prong (non-grounding) wall receptacle is intended to replace all safety precautions and warnings contained in accordance with the Parts Manual and Technical Sheet covering specific model being serviced. It is intended for ground wires is to...
Service Manual - Page 4

HSU18VH7 10070808 Product Features TEMP SIGNAL SENDING FAN SPEED SLEEP HEALTH POWER ON/OFF 18000/17800 BTU 1580/1560W/7/7.5A SEER:13.0/13.0 HSPF:7.7/7.7 18000/18000 BTU 1520/1480W/6.7/7.2A 500 CFM 1PH 230/208V ~ 60Hz
Service Manual - Page 7

... according to air conditioners of series models and electric control function. Tr≥23℃ b. Tr Ts+2℃, compressor, outdoor fan run continuously, indoor fan runs as per setting wind speed ...synchronous) indoor fan runs in the following selection conditions means room temperature, Ts means setting temperature, Tp means temperature of 3 minutes (State 2) 3.2.3.3 Tr Introduction to ...
Service Manual - Page 8

... of indoor fan under heating OFF state (applicable to setting wind speed. 3.2.5 Control of Tp-Tr If the temperature of indoor coil pipe is ≥ 23℃, start (preventing cold wind when heating running begins, applicable to fan-coil model) Defrosting beginning condition: a. Air conditioner Edition: 10070808 State1 State3 State2 Ts-1 Ts Ts+2 Ts...
Service Manual - Page 9

...and dehumidifying state, the air conditioner will control the outdoor fan as per the temperature Tp of indoor coil pipe: Under heating state, the air conditioner will maintain pause for .... Function setting: Pressing the SLEEP button on the remote control unit for 3 minutes. 3.2.9 Overload protection during running due to power failure, or closed for maintenance or troubleshooting, it ...
Service Manual - Page 10

... speed mode. 3.2.12 Emergency running refrigerating mode, Ts = 26℃; Tr The rules of click from the buzzer, then the air conditioner will turn to the trial run are as follows: a. c. Air conditioner Edition: 10070808 temperature, sleep state, flap state. Cancellation of function: Pressing the SLEEP button on the remote control unit for 5 seconds...
Service Manual - Page 11

Air conditioner Edition: 10070808 running for 1 hour under heating mode, the setting temperature will decrease 2℃, after another 1 hour, it will decrease the 2℃ again, and after 3 hours, it will increase 1℃, and after other 3 hours, it will cease. MODEL HSU18VH7 PCB 0010403861 The SW2 select"25"OR "35" 25 - 9-
Service Manual - Page 13

...specifications of the indoor unit is damaged and needs replacing. - 11- YES Pull out and reinsert the terminals. YES Replace with new sensor NO The Indoor PCB is broken YES Replace with the remote controller. Measure the voltage between its two jumpers 2)measure the temperature at the room temperature sensing head. Air conditioner...error or no Check whether the EEPROM is EEPROM installed...
Service Manual - Page 23

OUTDOOR UNIT Edition:10070808 WIRING DIAGRAM OF OUTDOOR UNIT 0010510468 B B RR ~ SCM C W W R B R BR ~M w B B W 1 234 5 67 GG TO INDOOR UNIT L2(N) L1(L) Grounding line Y/G:YELLOW/GREEN R:RED BL:BLUE Y:YELLOW B:BLACK BR:BROWN W:WHITE Note: Because of the difference of compressor, the dotted line part may not exist. 21

Haier HSU18VH7-W Reviews

Do you have an experience with the Haier HSU18VH7-W that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Haier yet.

Popular Haier HSU18VH7-W Search Terms

The following terms are frequently used to search for Haier HSU18VH7-W support:

Ask a New Question
Use the box below to post a new question about Haier HSU18VH7-W.
Manuals / Documents
Download any of our Haier HSU18VH7-W manuals for free!

We have the following 1 documents available for the Haier HSU18VH7-W:
  • Service Manual

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Haier Manuals

Find free Haier HSU18VH7-W - Ductless Split Outdoor Unit Heat Pump manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Haier Reviews

View thousands of Haier HSU18VH7-W - Ductless Split Outdoor Unit Heat Pump user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Haier customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Haier customer service rankings, employee comments and much more from our sister site.

Haier Recalls

Find comprehensive Haier recall information updated hourly on RecallOwl.com.