Haier HH-T890 Support and Manuals
Get Help and Manuals for this Haier item
This item is in your list!
View All Support Options Below
Free Haier HH-T890 manuals!
Problems with Haier HH-T890?
Ask a Question
Free Haier HH-T890 manuals!
Problems with Haier HH-T890?
Ask a Question
Popular Haier HH-T890 Manual Pages
HH-T890 Manual - Page 3
...
14
Troubleshooting
16
Manufacturer's Warranty
18
IMPORTANT! CONTENTS
Introduction
3
Safety and warnings
4
Installation instructions
5
About your local Haier dealer.
1 SAVE THESE INSTRUCTIONS
The models shown in this user guide may not be available in your country, please contact your rangehood
12
Operating instructions - For current details about model and specification...
HH-T890 Manual - Page 4
INTRODUCTION
Thank-you get the most out of your new rangehood.
2 We hope you enjoy your rangehood. This user guide explains the features and functions, and will help you for purchasing a Haier rangehood.
HH-T890 Manual - Page 5
...parts may become hot when used with reduced physical, sensory or mental capabilities shall notuse the range hood without a pot or pan covering it must be replaced by your Haier trained and supported service technician. ● The appliance shall be connected to get wet. IMPORTANT SAFETY INSTRUCTIONS
WARNING! Secure grounding is installed... in this user guide before operating this ...
HH-T890 Manual - Page 6
Different fixings will be required for other types of packaging
Rangehood (1)
Haier
Range Hood HH-T890 model
Installation instructions User guide manual (1)
Check valve assembly (1)
Universal ducting hose (180) (2)
Check valve gasket (1)
Wall plate (1)
Oil receptacle (1)
Inner decorative cover holder (1)
Self-tapping screw ST4 x 12 (4)
Cross recessed ...
HH-T890 Manual - Page 7
INSTALLATION INSTRUCTIONS
Names of principal components
Volute
Fan
Hand-tightened
nut
Intake ring
Main housing
Inner decorative cover
Outer decorative cover
Top cover
Check valve assembly
Oil filter
LED Light (1)
5
HH-T890 Manual - Page 9
max. 700
min. 610 min. 990
533
7 INSTALLATION INSTRUCTIONS
Height of rangehood
K
L J
MINIMUM CLEARANCES
J Height top of gas cooktop to base of rangehood
K Height of rangehood installation
if ducted through the ceiling if ducted through the rear
L Depth of rangehood installation
mm min. 650 -
HH-T890 Manual - Page 10
...; Use an impact drill with a φ10 mm masonry bit to the wall using the mounting screws.
3 Install the decorative cover holder (if inner decorative cover extension is heavy and requires two persons for installation.
INSTALLATION INSTRUCTIONS
Installation
WARNING!
Decorative cover holes
32 mm
280 mm 73 mm
50 mm
224 mm
50 mm
Stopper...
HH-T890 Manual - Page 11
Fig.3 9 INSTALLATION INSTRUCTIONS
Fig.2
4 Install the supports
Attach the supports to the back of the rangehood as shown in Fig.3.
HH-T890 Manual - Page 12
... the inner decorative cover (if inner decorative cover extension is pushed all protective wrappings.
10 Fig.4
11 Remove packaging
Remove all the way in. INSTALLATION INSTRUCTIONS
5 Connect the check valve assembly
Place the check valve gasket and check valve assembly onto the air outlet on top of the main unit, and ...
HH-T890 Manual - Page 14
... and the speed of the fan will switch in a loop of the fan will switch to high speed Turns the light on or off. OPERATING INSTRUCTIONS - Press this button could turn off .Lighting switch operates independently.
HH-T890 Manual - Page 15
...replace the oil receptacle slide it into the slot on
Fig.5
the filter and ensure it from sharp metal parts. ● Always handle removed parts carefully to avoid damaging them. ● Clean and service...and a soft cloth. Cleaning the oil filter (weekly) ● Remove oil receptacle (refer to
instructions above).
● Loosen the screw securing the oil filter̻
● The oil filter ...
HH-T890 Manual - Page 16
... vibration of the entire rangehood, leading to increased noise. ● To reassemble replace the parts in a clockwise direction to remove the fan. ● Take particular care when... cleaning the fan that the clips on the blades are not moved or
lost, as to maintain venting
performance and ensure a long service...
HH-T890 Manual - Page 17
... repair. Press the light button.
TROUBLESHOOTING
Solutions for common faults
In case of bends. PROBLEM No power.
Shared flue aperture is too narrow or the air outlet is too long, has not been stretched tight, or has too many bends. Replace the light (please contact the after -sales service centre. Replace the fan (please contact the service...
HH-T890 Manual - Page 18
...TO DO
Remove waste oil in accordance with the instructions. CAUSE
Air pressure causes the two blades of ...service centre.
1 The rangehood runs unevenly when turned on; 2 The rangehood makes an unusual noise during operation. Note: if you are unable to fix the problem by themselves, emitting a clicking noise.
16
Filter and filter recess have not been cleaned. TROUBLESHOOTING
PROBLEM...
HH-T890 Manual - Page 19
... will be charged if the problem is found to use in the product's user guide. G Pick -up and delivery. This product is installed outside the
Haier Authorised Repairer's normal service area.
E Normal r ecommended maintenance as set out in a normal domestic (residential) environment. This product has been designed for use the product. 3 Replacing house fuses or correcting house...
Haier HH-T890 Reviews
Do you have an experience with the Haier HH-T890 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Haier yet.
Earn 750 points for your review!