Fluke 114,115,117 Manual
Page 1
® 114, 115, and 117 True-rms Multimeters Users Manual PN 2572573 July 2006, Rev. 1, 2/07 © 2006, 2007 Fluke Corporation, All rights reserved. Printed in China All product names are trademarks of their respective companies.
® 114, 115, and 117 True-rms Multimeters Users Manual PN 2572573 July 2006, Rev. 1, 2/07 © 2006, 2007 Fluke Corporation, All rights reserved. Printed in China All product names are trademarks of their respective companies.
Fluke 114,115,117 Manual
Page 4
.... These voltages pose a shock hazard. • Disconnect circuit power and discharge all high-voltage capacitors before opening the battery door or Meter case. 2 114, 115, and 117 Users Manual Safety Information A "XWWarning" statement identifies hazardous conditions and actions that could damage the Meter or the equipment under test. To avoid possible electric shock...
.... These voltages pose a shock hazard. • Disconnect circuit power and discharge all high-voltage capacitors before opening the battery door or Meter case. 2 114, 115, and 117 Users Manual Safety Information A "XWWarning" statement identifies hazardous conditions and actions that could damage the Meter or the equipment under test. To avoid possible electric shock...
Fluke 114,115,117 Manual
Page 6
The Meter function is set to Diode Test Input is in the VoltAlert™ non-contact voltage detect mode. edy02f.eps Model 117 114, 115, & 117 115 & 117 114, 115, & 117 114, 115, & 117 A B C D E 4 Symbol w s R O Y 6 5 4 3 2 1 16 15 VoltAlert 7 14 17 8 9 10 11 12 13 18 Meaning The Meter is a negative value. X Unsafe voltage. Measured input voltage ≥30 V, or voltage overload condition (OL). The Meter function is set to Continuity. 114, 115, and 117 Users Manual Display No.
The Meter function is set to Diode Test Input is in the VoltAlert™ non-contact voltage detect mode. edy02f.eps Model 117 114, 115, & 117 115 & 117 114, 115, & 117 114, 115, & 117 A B C D E 4 Symbol w s R O Y 6 5 4 3 2 1 16 15 VoltAlert 7 14 17 8 9 10 11 12 13 18 Meaning The Meter is a negative value. X Unsafe voltage. Measured input voltage ≥30 V, or voltage overload condition (OL). The Meter function is set to Continuity. 114, 115, and 117 Users Manual Display No.
Fluke 114,115,117 Manual
Page 7
... 117 5 The Meter selects the range for the selected range. 114, 115, & 117 R LEAd W Test lead alert. True-rms Multimeters Display F K Display hold enabled. Display freezes present reading. 114, 115, & 117 G M MIN MAX AVG mode enabled. Briefly... displayed whenever the Meter's function switch is in the Auto Volts function. 114 & 117 Auto Autoranging. User sets the Meter's range. 114, 115, & 117 P + Bar graph polarity 114, 115, & 117 Q 0L W The input is too large for best resolution. 114, 115, & 117 Manual Manual...
... 117 5 The Meter selects the range for the selected range. 114, 115, & 117 R LEAd W Test lead alert. True-rms Multimeters Display F K Display hold enabled. Display freezes present reading. 114, 115, & 117 G M MIN MAX AVG mode enabled. Briefly... displayed whenever the Meter's function switch is in the Auto Volts function. 114 & 117 Auto Autoranging. User sets the Meter's range. 114, 115, & 117 P + Bar graph polarity 114, 115, & 117 Q 0L W The input is too large for best resolution. 114, 115, & 117 Manual Manual...
Fluke 114,115,117 Manual
Page 8
...B Common (return) terminal for measuring ac and dc current to 10 A. The Meter must be replaced before it will operate. edy01f.eps Model 115 & 117 114, 115, & 117 114, 115, & 117 bAtt CAL Err EEPr Err F11 Err Error Messages Battery must be repaired before the Meter will operate. Internal error. Description... and testing diodes. The Meter must be repaired before the Meter will operate. 6 Meter calibration is required before it will operate. Calibration required. Internal error. 114, 115, and 117 Users Manual Terminals 1 V A COM 3 10 A FUSED 2 No.
...B Common (return) terminal for measuring ac and dc current to 10 A. The Meter must be replaced before it will operate. edy01f.eps Model 115 & 117 114, 115, & 117 114, 115, & 117 bAtt CAL Err EEPr Err F11 Err Error Messages Battery must be repaired before the Meter will operate. Internal error. Description... and testing diodes. The Meter must be repaired before the Meter will operate. 6 Meter calibration is required before it will operate. Calibration required. Internal error. 114, 115, and 117 Users Manual Terminals 1 V A COM 3 10 A FUSED 2 No.
Fluke 114,115,117 Manual
Page 10
... Press fto activate Display HOLD. (K is detected, the Meter beeps. • Put the Meter in the MIN MAX AVG mode. Manual and Autoranging The Meter has both Manual and Autorange modes. • In the Autorange mode, the Meter selects the range with the best resolution. • In the...MIN MAX AVG recording mode captures the minimum and maximum input values (ignoring overloads), and calculates a running average of all readings. 114, 115, and 117 Users Manual Battery Saver ("Sleep Mode") The Meter automatically enters "Sleep mode" and blanks the display if there is no function change, range...
... Press fto activate Display HOLD. (K is detected, the Meter beeps. • Put the Meter in the MIN MAX AVG mode. Manual and Autoranging The Meter has both Manual and Autorange modes. • In the Autorange mode, the Meter selects the range with the best resolution. • In the...MIN MAX AVG recording mode captures the minimum and maximum input values (ignoring overloads), and calculates a running average of all readings. 114, 115, and 117 Users Manual Battery Saver ("Sleep Mode") The Meter automatically enters "Sleep mode" and blanks the display if there is no function change, range...
Fluke 114,115,117 Manual
Page 12
114, 115, and 117 Users Manual Measuring Resistance Testing for Continuity XWWarning edy04f.eps To avoid electric shock, injury, or damage to the Meter, disconnect circuit power and discharge all highvoltage capacitors before testing resistance, continuity, diodes, or capacitance. 10 edy06f.eps Note The continuity function works best as a fast, convenient method to check for opens and shorts. For maximum accuracy in making resistance measurements, use the Meter's resistance (e) function.
114, 115, and 117 Users Manual Measuring Resistance Testing for Continuity XWWarning edy04f.eps To avoid electric shock, injury, or damage to the Meter, disconnect circuit power and discharge all highvoltage capacitors before testing resistance, continuity, diodes, or capacitance. 10 edy06f.eps Note The continuity function works best as a fast, convenient method to check for opens and shorts. For maximum accuracy in making resistance measurements, use the Meter's resistance (e) function.
Fluke 114,115,117 Manual
Page 14
114, 115, and 117 Users Manual Measuring AC or DC Current (115 & 117) XWWarning To avoid personal injury or damage to the Meter: • Never attempt to make an in-circuit ...
114, 115, and 117 Users Manual Measuring AC or DC Current (115 & 117) XWWarning To avoid personal injury or damage to the Meter: • Never attempt to make an in-circuit ...
Fluke 114,115,117 Manual
Page 16
Frequency works with ac functions only. Select progressively lower ranges using manual ranging for all ranges. 14 VoltAlert edy13f.eps If the frequency of times the signal crosses a trigger level each second. In frequency, the bar ... the bar graph and Z are unspecified. AC Voltage Frequency AC Current Frequency VoltAlert Hz Press g to turn the frequency measurement function on and off. 114, 115, and 117 Users Manual Measuring Frequency (115 & 117 only) XWWarning To avoid electrical shock, disregard the bar graph for frequencies >1 kHz. Detecting AC Voltage Presence (117 only...
Frequency works with ac functions only. Select progressively lower ranges using manual ranging for all ranges. 14 VoltAlert edy13f.eps If the frequency of times the signal crosses a trigger level each second. In frequency, the bar ... the bar graph and Z are unspecified. AC Voltage Frequency AC Current Frequency VoltAlert Hz Press g to turn the frequency measurement function on and off. 114, 115, and 117 Users Manual Measuring Frequency (115 & 117 only) XWWarning To avoid electrical shock, disregard the bar graph for frequencies >1 kHz. Detecting AC Voltage Presence (117 only...
Fluke 114,115,117 Manual
Page 18
... the bar graph is much faster than the digital display, the bar graph is disabled when measuring capacitance. The number of the selected range. 114, 115, and 117 Users Manual Using the Bargraph The bar graph is relative to 1 kHz. Testing the Fuse (115 & 117 only) Test fuse as shown below ), the major...
... the bar graph is much faster than the digital display, the bar graph is disabled when measuring capacitance. The number of the selected range. 114, 115, and 117 Users Manual Using the Bargraph The bar graph is relative to 1 kHz. Testing the Fuse (115 & 117 only) Test fuse as shown below ), the major...
Fluke 114,115,117 Manual
Page 20
... the fuse from the Meter 2. Separate the case bottom from the case bottom. 4. Dirt or moisture in the terminals can affect readings. 18 Use only Fluke PN 803293. 6. Finally, insert the Meter into its holster. Remove two screws from the case top. 5. Remove the test leads from its holster. 3. Cleaning Wipe... bottom to clean the case or lens/window. Do not use abrasives, isopropyl alcohol, or solvents to the case top, then install the two screws. 114, 115, and 117 Users Manual To open the case for fuse replacement: 1.
... the fuse from the Meter 2. Separate the case bottom from the case bottom. 4. Dirt or moisture in the terminals can affect readings. 18 Use only Fluke PN 803293. 6. Finally, insert the Meter into its holster. Remove two screws from the case top. 5. Remove the test leads from its holster. 3. Cleaning Wipe... bottom to clean the case or lens/window. Do not use abrasives, isopropyl alcohol, or solvents to the case top, then install the two screws. 114, 115, and 117 Users Manual To open the case for fuse replacement: 1.
Fluke 114,115,117 Manual
Page 22
114, 115, and 117 Users Manual Certifications UL, P, CSA, TÜV, ; (N10140), VDE IP Rating (dust and water protection IP42 Table 1. Accuracy Specifications Function DC millivolts DC Volts Range 600.0 mV 6.000 V ...] + [Counts]) 0.1 mV 0.001 V 0.01 V 0.1 V 0.1 V 0.1 mV 0.5 % + 2 0.5 % + 2 DC, 45 to 500 Hz 2.0 % + 3 45 to 500 Hz 1.0 % + 3 500 Hz to 1 kHz 4.0 % + 3 500 Hz to 1 kHz 2.0 % + 3 0.001 V 0.01 V 0.1 V 1.0 % + 3 2.0 % + 3 Model 114, 115, 117 114, 115, 117 114, 117 114, 115, 117 114, 115, 117 20
114, 115, and 117 Users Manual Certifications UL, P, CSA, TÜV, ; (N10140), VDE IP Rating (dust and water protection IP42 Table 1. Accuracy Specifications Function DC millivolts DC Volts Range 600.0 mV 6.000 V ...] + [Counts]) 0.1 mV 0.001 V 0.01 V 0.1 V 0.1 V 0.1 mV 0.5 % + 2 0.5 % + 2 DC, 45 to 500 Hz 2.0 % + 3 45 to 500 Hz 1.0 % + 3 500 Hz to 1 kHz 4.0 % + 3 500 Hz to 1 kHz 2.0 % + 3 0.001 V 0.01 V 0.1 V 1.0 % + 3 2.0 % + 3 Model 114, 115, 117 114, 115, 117 114, 117 114, 115, 117 114, 115, 117 20
Fluke 114,115,117 Manual
Page 24
... 50 kHz. Auto-V LoZ is specified from 45 Hz to 5 kHz. [3] >10 A unspecified. 22 AutoV LoZ, AC mV, and AC amps are shorted together. 114, 115, and 117 Users Manual Table 1 Accuracy Specifications (cont.) Function Range Resolution Accuracy ± ([% of Reading] + [Counts]) Model AC Amps Truerms[1] (45 Hz to 500 Hz) 6.000 A 10...
... 50 kHz. Auto-V LoZ is specified from 45 Hz to 5 kHz. [3] >10 A unspecified. 22 AutoV LoZ, AC mV, and AC amps are shorted together. 114, 115, and 117 Users Manual Table 1 Accuracy Specifications (cont.) Function Range Resolution Accuracy ± ([% of Reading] + [Counts]) Model AC Amps Truerms[1] (45 Hz to 500 Hz) 6.000 A 10...
Fluke 114 Digital Multimeter Datasheet
Page 2
... < 20 W, off > 250 W; Printed in U.S.A. 8/2006 2634055 D-EN-N Rev A AC volts is normal for ac voltage. Ordering Information Fluke-114 Electrical Multimeter Included TL75 Test leads, holster, User's manual and 9 V battery (installed). Fluke Corporation 114 Electrical Multimeter Fluke. PO Box 1186, 5602 BD Eindhoven, The Netherlands For more information call: In the U.S.A. (800) 443-5853 or Fax...
... < 20 W, off > 250 W; Printed in U.S.A. 8/2006 2634055 D-EN-N Rev A AC volts is normal for ac voltage. Ordering Information Fluke-114 Electrical Multimeter Included TL75 Test leads, holster, User's manual and 9 V battery (installed). Fluke Corporation 114 Electrical Multimeter Fluke. PO Box 1186, 5602 BD Eindhoven, The Netherlands For more information call: In the U.S.A. (800) 443-5853 or Fax...