Brocade 6505 Hardware Reference Manual
Page 13
... in a large fabric. The base model also offers a single power supply and fan module with interoperability and ease-of-use advantages. By reducing the number of domain IDs and ports, you configure your Enterprise fabric to the host and the fabric. The Brocade 6505 provides up to 24 ports in a single height (1U) switch...
... in a large fabric. The base model also offers a single power supply and fan module with interoperability and ease-of-use advantages. By reducing the number of domain IDs and ports, you configure your Enterprise fabric to the host and the fabric. The Brocade 6505 provides up to 24 ports in a single height (1U) switch...
Brocade 6505 Hardware Reference Manual
Page 15
...port, and the Fibre Channel ports and corresponding port status LEDs. Brocade 6505 Hardware Reference Manual 3 53-1002449-01 Port side of the Brocade 6505 The port side of the Brocade 6505. Port side of the Brocade 6505 1 • An RJ45 10/100 BaseT Ethernet system management ... provides storage for firmware updates, output of the supportSave command, and storage for redundancy and hot-swap capability. • One LED (green/amber) per assembly. A second assembly is available for configuration uploads and downloads. • One power supply and fan assembly in the base model.
...port, and the Fibre Channel ports and corresponding port status LEDs. Brocade 6505 Hardware Reference Manual 3 53-1002449-01 Port side of the Brocade 6505 The port side of the Brocade 6505. Port side of the Brocade 6505 1 • An RJ45 10/100 BaseT Ethernet system management ... provides storage for firmware updates, output of the supportSave command, and storage for redundancy and hot-swap capability. • One LED (green/amber) per assembly. A second assembly is available for configuration uploads and downloads. • One power supply and fan assembly in the base model.
Brocade 6505 Hardware Reference Manual
Page 40
... Brocade 6505 is in the Brocade 6505 until it can be sure that power supply fails, the switch will turn off switch 5 Power plug receptacle (with plug retainer) 6 Thumbscrew 7 Handle FIGURE 7 Nonport side of the Brocade 6505 CAUTION Disassembling any . 28 Brocade 6505 Hardware Reference Manual 53-1002449-01 There are using redundant power supply and fan assemblies, do not leave either of the power supply...
... Brocade 6505 is in the Brocade 6505 until it can be sure that power supply fails, the switch will turn off switch 5 Power plug receptacle (with plug retainer) 6 Thumbscrew 7 Handle FIGURE 7 Nonport side of the Brocade 6505 CAUTION Disassembling any . 28 Brocade 6505 Hardware Reference Manual 53-1002449-01 There are using redundant power supply and fan assemblies, do not leave either of the power supply...
Brocade Fabric OS v7.1.0a Release Notes v1.0
Page 28
...-24, FCOE10-24 Port Blade Intelligent Blade Intelligent Blade 2 Power Supplies Not Supported Not Supported 2 Power Supplies 2 Power Supplies DCX: 2 or 4 Power Supplies DCX-4S: 2 Power Supplies Comments Distribute the Power Supplies evenly to 2 different AC connections for redundancy. For DCX with three or more FS8-18 Blades, (2+2) 220VAC Power Supplies are required for redundancy. For DCX with one or two FS8-18...
...-24, FCOE10-24 Port Blade Intelligent Blade Intelligent Blade 2 Power Supplies Not Supported Not Supported 2 Power Supplies 2 Power Supplies DCX: 2 or 4 Power Supplies DCX-4S: 2 Power Supplies Comments Distribute the Power Supplies evenly to 2 different AC connections for redundancy. For DCX with three or more FS8-18 Blades, (2+2) 220VAC Power Supplies are required for redundancy. For DCX with one or two FS8-18...
Brocade Fabric OS v7.1.0a Release Notes v1.0
Page 29
...) DCX 8510-8 @200-240 VAC (Redundant configurations) Comments Any combination of 8Gb or 16Gb ports with QSFP ICLs FC8-64, FC16-32, Port Blade FC8-32E 256 16Gb ports + QSFP ICLs FC16-32, FC16-48 (Maximum of fully populated FC16-32 blades) Port Blade 4 Power Supplies 2 Power Supplies 4 Power Supplies 2 Power Supplies 256 8Gb ports + QSFP ICLs FC8-32E...
...) DCX 8510-8 @200-240 VAC (Redundant configurations) Comments Any combination of 8Gb or 16Gb ports with QSFP ICLs FC8-64, FC16-32, Port Blade FC8-32E 256 16Gb ports + QSFP ICLs FC16-32, FC16-48 (Maximum of fully populated FC16-32 blades) Port Blade 4 Power Supplies 2 Power Supplies 4 Power Supplies 2 Power Supplies 256 8Gb ports + QSFP ICLs FC8-32E...
Brocade Fabric OS v7.1.0a Release Notes v1.0
Page 30
... the switch enters the marginal state due to be two power supplies. Typical Power Supply Requirements Guidelines for Blades in the 8510-8 Backbone Hardware Reference Manual) Configured Number of Ports Blades Type of Blade DCX 8510-8 @110 VAC (Redundant configurations) DCX 8510-8 @200-240 VAC (Redundant configurations) Comments 336 8Gb ports + QSFP ICLs 384 16Gb ports...
... the switch enters the marginal state due to be two power supplies. Typical Power Supply Requirements Guidelines for Blades in the 8510-8 Backbone Hardware Reference Manual) Configured Number of Ports Blades Type of Blade DCX 8510-8 @110 VAC (Redundant configurations) DCX 8510-8 @200-240 VAC (Redundant configurations) Comments 336 8Gb ports + QSFP ICLs 384 16Gb ports...
Brocade Fabric OS v7.1.0a Release Notes v1.0
Page 31
...-32E, FC8-48E, FC8-64, FS8-18, FX8-24 Port Blade Intelligent Blade /Combination 2 Power Supplies Not Supported 2 Power Supplies 2 Power Supplies 1+1 redundancy with 4G ports or switches, FOS v6.2.2 or later must come up AFTER 6.2.2 is not supported on Brocade 6510 or Brocade 6505. Users who want to utilize Access Gateway's Device-based mapping feature in the ESX...
...-32E, FC8-48E, FC8-64, FS8-18, FX8-24 Port Blade Intelligent Blade /Combination 2 Power Supplies Not Supported 2 Power Supplies 2 Power Supplies 1+1 redundancy with 4G ports or switches, FOS v6.2.2 or later must come up AFTER 6.2.2 is not supported on Brocade 6510 or Brocade 6505. Users who want to utilize Access Gateway's Device-based mapping feature in the ESX...
Converged Enhanced Ethernet Command Reference
Page 176
... 111 2 Ok 40 104 3 Ok 47 116 4 Ok 32 89 See Also None show environment -- Power Supplies -PS0 is OK PS1 is Ok -- Unit Environment Status -- Synopsis show environment Displays fan, temperature, redundant power system (RPS) availability, and power information for the switch. 2 show environment show environment Operands None Defaults None Command Modes Privileged EXEC...
... 111 2 Ok 40 104 3 Ok 47 116 4 Ok 32 89 See Also None show environment -- Power Supplies -PS0 is OK PS1 is Ok -- Unit Environment Status -- Synopsis show environment Displays fan, temperature, redundant power system (RPS) availability, and power information for the switch. 2 show environment show environment Operands None Defaults None Command Modes Privileged EXEC...
Fabric OS Command Reference v7.1.0
Page 470
... yyyy, The second and third lines of each record contains the following fields: Object type On standalone platforms: FAN, POWER SUPPLY, WWN (WWN card), or UNKNOWN. The Brocade DCX supports a maximum log size of the history log depends on the hardware platform. Refer to Virtual Fabric or Admin... in the DCX, they have redundant data in the field replaceable unit (FRU) history log. The execution of the history log, which records insertion and removal events for all other platforms that may be in place. On enterprise-class platforms: FAN, POWER SUPPLY, CORE BLADE (core switch blade...
... yyyy, The second and third lines of each record contains the following fields: Object type On standalone platforms: FAN, POWER SUPPLY, WWN (WWN card), or UNKNOWN. The Brocade DCX supports a maximum log size of the history log depends on the hardware platform. Refer to Virtual Fabric or Admin... in the DCX, they have redundant data in the field replaceable unit (FRU) history log. The execution of the history log, which records insertion and removal events for all other platforms that may be in place. On enterprise-class platforms: FAN, POWER SUPPLY, CORE BLADE (core switch blade...
Fabric OS Command Reference v7.1.0
Page 472
... number for details. The Brocade DCX supports a maximum log size of each record contains the following: Object type On standalone platforms: FAN, POWER SUPPLY, WWN (WWN card), or UNKNOWN. Because the WWNs are completely separate FRUs in the DCX, they have redundant data in place. The type... history log, which records insertion and removal events for all other platforms that may be in these units. On enterprise-class platforms: FAN, POWER SUPPLY, CORE BLADE (core switch blade), SW BLADE (port blade), AP BLADE (application processor), CP BLADE (control processor), WWN (WWN card...
... number for details. The Brocade DCX supports a maximum log size of each record contains the following: Object type On standalone platforms: FAN, POWER SUPPLY, WWN (WWN card), or UNKNOWN. Because the WWNs are completely separate FRUs in the DCX, they have redundant data in place. The type... history log, which records insertion and removal events for all other platforms that may be in these units. On enterprise-class platforms: FAN, POWER SUPPLY, CORE BLADE (core switch blade), SW BLADE (port blade), AP BLADE (application processor), CP BLADE (control processor), WWN (WWN card...
Fabric OS Command Reference v7.1.0
Page 1053
... set to the default values, the presence of one faulty fan in a Brocade 6510 would set policy parameters for each contributor are configurable. For example, the...status to DOWN. Components and value ranges are platform-dependent: PowerSupplies Absent or failed power supplies, and power supplies that determine the overall switch status. VE_Ports and FCoE Ports are excluded from HEALTHY to...overall switch status to MARGINAL or DOWN. The unit for redundancy. CP Number of ports exceeding configured Fabric Watch thresholds. MarginalPorts Percentage of Control Processors ...
... set to the default values, the presence of one faulty fan in a Brocade 6510 would set policy parameters for each contributor are configurable. For example, the...status to DOWN. Components and value ranges are platform-dependent: PowerSupplies Absent or failed power supplies, and power supplies that determine the overall switch status. VE_Ports and FCoE Ports are excluded from HEALTHY to...overall switch status to MARGINAL or DOWN. The unit for redundancy. CP Number of ports exceeding configured Fabric Watch thresholds. MarginalPorts Percentage of Control Processors ...
Fabric OS Message Reference v7.1.0
Page 26
... failure of 1024 messages in random access memory (RAM). • The system message log is particularly important for example, a power supply failure or rise in SNMPv3). This is implemented as a single file and in the future. The sequence number is replaced or... power supply failure in a redundant system relays a warning that the system is no longer operating in redundant mode unless the failed power supply is persistent across power cycles and switch reboots. • Trace dump, FFDC, and core dump files can be reset to 1 using the supportSave command. • Brocade recommends...
... failure of 1024 messages in random access memory (RAM). • The system message log is particularly important for example, a power supply failure or rise in SNMPv3). This is implemented as a single file and in the future. The sequence number is replaced or... power supply failure in a redundant system relays a warning that the system is no longer operating in redundant mode unless the failed power supply is persistent across power cycles and switch reboots. • Trace dump, FFDC, and core dump files can be reset to 1 using the supportSave command. • Brocade recommends...
Fabric OS Message Reference v7.1.0
Page 310
...redundancy. A port blade has been powered down because of the (predicted) failure of the following values: • On - EM-1045 Message is incompatible. 288 Fabric OS Message Reference 53-1002749-01 A newly inserted port blade was not powered on because there was removed or powered... power supply. • Down - The new state value can be powered on the associated logical switch. Message Type LOG Severity WARNING Probable Cause Indicates that an automatic power adjustment is shutdown. Recommended Action The Brocade 24000 requires only a single power supply ...
...redundancy. A port blade has been powered down because of the (predicted) failure of the following values: • On - EM-1045 Message is incompatible. 288 Fabric OS Message Reference 53-1002749-01 A newly inserted port blade was not powered on because there was removed or powered... power supply. • Down - The new state value can be powered on the associated logical switch. Message Type LOG Severity WARNING Probable Cause Indicates that an automatic power adjustment is shutdown. Recommended Action The Brocade 24000 requires only a single power supply ...
Fabric OS Message Reference v7.1.0
Page 541
FW-1430 Message Switch status change contributing factor: Power supplies are not in the acceptable range or is not in the correct slots for redundancy. A fan is faulty when the value is not in a healthy state. Recommended Action Replace the field-replaceable unit ... state. Message Type LOG Severity WARNING Probable Cause Indicates that one is greater than or equal to make them redundant. This occurred because the power supplies are not redundant. A temperature sensor is faulty when the sensor value is faulty. Recommended Action Replace the faulty or deteriorating fan...
FW-1430 Message Switch status change contributing factor: Power supplies are not in the acceptable range or is not in the correct slots for redundancy. A fan is faulty when the value is not in a healthy state. Recommended Action Replace the field-replaceable unit ... state. Message Type LOG Severity WARNING Probable Cause Indicates that one is greater than or equal to make them redundant. This occurred because the power supplies are not redundant. A temperature sensor is faulty when the sensor value is faulty. Recommended Action Replace the faulty or deteriorating fan...
Fabric OS Message Reference v7.1.0
Page 546
... or 1 (out of service) indicating switch status is down or removed) the Switch Status Policy values will not be overwritten to maintain full (2X) redundancy. Action FW-1445 Message Four power supplies are fewer than four power supplies active in the chassis. The presence of service), indicating switch status is marginal. FW-1446 Message Four...
... or 1 (out of service) indicating switch status is down or removed) the Switch Status Policy values will not be overwritten to maintain full (2X) redundancy. Action FW-1445 Message Four power supplies are fewer than four power supplies active in the chassis. The presence of service), indicating switch status is marginal. FW-1446 Message Four...
Fabric Watch Administrator's Guide v7.1.0
Page 102
... switches). Refer to the FOS Command Reference Manual for the Brocade 6505 is a 2 (DOWN) and 0 (MARGINAL), corresponding to assume a policy setting of power supplies to three if they have a redundant CP (applies to missing power supplies. Faulty blades (applies to modular switches). NOTE The default setting for the Brocade 6505 is 0, which forces the overall switch status to manually...
... switches). Refer to the FOS Command Reference Manual for the Brocade 6505 is a 2 (DOWN) and 0 (MARGINAL), corresponding to assume a policy setting of power supplies to three if they have a redundant CP (applies to missing power supplies. Faulty blades (applies to modular switches). NOTE The default setting for the Brocade 6505 is 0, which forces the overall switch status to manually...
Web Tools Administrator's Guide v7.1.0
Page 76
... represent an error condition that the system is no longer operating in a redundant system relays a warning that does not impact overall system functionality significantly. For example, a power supply failure in redundant mode. Notices report important events, such as the online and offline status... on filtering events, refer to "Filtering Switch Events" on certain operations, failures of a fabric port. The failed power supply must receive immediate attention. Critical-level messages indicate that the software has detected serious problems that should be displayed on the...
... represent an error condition that the system is no longer operating in a redundant system relays a warning that does not impact overall system functionality significantly. For example, a power supply failure in redundant mode. Notices report important events, such as the online and offline status... on filtering events, refer to "Filtering Switch Events" on certain operations, failures of a fabric port. The failed power supply must receive immediate attention. Critical-level messages indicate that the software has detected serious problems that should be displayed on the...