... (fc1) TAC Support: http://www.cisco.com/tac Copyright (c) 1986-2002 by Cisco Systems, Inc. All rights reserved. Printed in USA. Processor board ID FOX062105FU Last reset from Redundancy Reset 76 Gigabit Ethernet/IEEE 802.3 interface(s) 403K bytes of memory. Configuration register is "bootflash:cat4000-i5s-mz.122-18.EW.bin" cisco WS-C4507R (XPC8245) processor (revision 4) with...
Troubleshooting Guide - Page 7

... bytes to 17442 bytes • Resets the modules so they can perform self diagnostics • Parses the configuration • Waits for Switchover Activity * cisco WS-C4507R (MPC8245) processor (revision 4) with 524288K bytes of non-volatile configuration memory. Supervisor Redundancy During Switchover the Standby Supervisor • Completes the booting sequence * STANDBY...
Troubleshooting Guide - Page 63

....htm RST-3508 9805_05_2004_c2 © 2004 Cisco Systems, Inc. All rights reserved. 125 Troubleshooting Support for Cisco Catalyst 4000 Series Switches: Cisco Technical Support Website www.cisco.com/techsupport Troubleshooting Section Includes: • Known problems (e.g., release notes, field notices, security advisories) • Troubleshooting resources for Catalyst 4000/4912G/2980G...
Troubleshooting Guide - Page 64

...-3508 9805_05_2004_c2 © 2003, Cisco Systems, Inc. Presentation_ID.scr Troubleshooting Support for Cisco Catalyst 4000 Series Switches: Cisco Technical Support Website www.cisco.com/techsupport Troubleshooting Section Includes: • Known problems (e.g., release notes, field notices, security advisories) • Troubleshooting resources for common error messages, CPU utilization, etc...
Software Guide - Page 29

... troubleshoot and resolve technical issues with a Cisco product, technology, or solution. Cisco TAC Website The Cisco TAC website provides online documents and tools to this URL: http://www.cisco.com...contact the TAC Escalation Center with a P1 or P2 problem, a Cisco TAC engineer automatically opens a case. Two types of support are willing to commit resources during normal business hours to...
Software Guide - Page 177

...in your network. (VTP version 1 and VTP version 2 do not support VLANs 1025-4094.) With VTP, you can result in the network. ...Guide-Release 8.1 9-1 VTP minimizes misconfigurations and configuration inconsistencies that maintains VLAN configuration consistency by managing the addition, deletion, and renaming of problems, such as duplicate VLAN names, incorrect VLAN-type specifications...
Software Guide - Page 222

..., including broadcasts, from other ports within the same private VLAN. The three types of supporting VLANs that port. Ports belonging to a private VLAN are used to create the private ...Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 Table 10-3 lists the set of private VLAN ports are isolated at Layer 2 from the...
Software Guide - Page 298

...error is returned. Command show gmrp statistics 23 GMRP Statistics for vlan : Total valid GMRP Packets Received:500 Join Empties:200 Join INs:250 15-14 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 Set...GMRP Chapter 15 Configuring Multicast Services When you set the timer values, the value for leave must be equal ...
Software Guide - Page 300

... Multicast Services Specifying Multicast Router Ports When you can manually specify multicast router ports. Console> (enable) set cam static...manually): Console> (enable) set multicast router mod_num/port_num show multicast group CGMP enabled IGMP disabled 15-16 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 Command set...
Software Guide - Page 423

.... Variable power supplies automatically adjust the power resources to accommodate the chassis and inline power requirements. • When your switch is set your switch, the switch uses the power supply in power supply bay 1 (PS1) and ignores the power supply in power supply bay (PS2). The power supplies have no power redundancy. • The 1400 W DC power supply does not support combined mode...
Software Guide - Page 480

...:750 Kerberos DomainRealm entries: Domain:cisco.com, Realm:CISCO.COM Kerberos Clients NOT Mandatory Kerberos Credentials Forwarding Enabled Kerberos Pre Authentication Method set to other services on the network with Kerberized clients. clear kerberos credentials forward 30-36 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01
Command Reference - Page 127

...error-disable cause. Specifies detection for the DHCP rate limit error-disable cause. Command Modes Global configuration Command History Release 12.1(8a)EW Modification Support for this command. Chapter2 Cisco...pagp-flap Specifies error disable detection to recover an interface manually from a specific cause. Specifies detection for the link-flap error disable cause: Switch...
Command Reference - Page 395

... attached to an interface with external power, the switch does not recognize the powered device. If your port is not capable of supporting Power over Ethernet, you will receive the following error message: Power over Ethernet not supported on interface Admin The show power [available | capabilities | detail | inline {[interface] | consumption default | module mod} | module | status | supplies...
Command Reference - Page 497

... to a secure port, an error message appears, and the security settings are in the error-disabled state, you can remove ...be dynamically configured. If you can manually reenable it from the secure address list. Add support for this state by entering the ... a particular port, set the maximum allowed secure addresses on the Catalyst 4500 series switch. Chapter2 Cisco IOS Commands for the...
Command Reference - Page 573

... SNAP SNMP SPAN SRB SRT SSTP STP SVC SVI Security Association Identifier service access point service connection manager Switch-Module Configuration Protocol Synchronous Data Link Control Stack Group Bidding Protocol single in-line memory module server load balancing Supervisor Line-Card Processor Serial Line Internet Protocol Software Management and Delivery Systems software MAC filter Standby...

Cisco WS-C4507R Reviews

Do you have an experience with the Cisco WS-C4507R that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Cisco yet.

Popular Cisco WS-C4507R Search Terms

The following terms are frequently used to search for Cisco WS-C4507R support:

Ask a New Question
Use the box below to post a new question about Cisco WS-C4507R.
Manuals / Documents
Download any of our Cisco WS-C4507R manuals for free!

We have the following 3 documents available for the Cisco WS-C4507R:
  • Software Guide
  • Command Reference
  • Troubleshooting Guide

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Cisco Manuals

Find free Cisco WS-C4507R manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Cisco Reviews

View thousands of Cisco WS-C4507R user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Cisco customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Cisco customer service rankings, employee comments and much more from our sister site.