User Guide
Page 98
... setup Configuration options: [Enabled] [Disabled] The following item becomes configurable when you set All LED Control to [Enabled]. 3.5.6 LCD Poster and LED Control BIOS SETUP UTILITY Advanced LCD Poster and LED Control LCD Poster Backlight [Turn Off] LCD Poster Backlight(S5) [Turn Off] LCD Poster Mode [Current... you to select which hardware information to turn on the LCD Poster. Configuration options: [All Voltage] [All Temperature] [All Fan Speed] All LED Control [Enabled] Allows you to display on /off the LCD Poster backlight when the system is in soft-off the LCD Poster...
... setup Configuration options: [Enabled] [Disabled] The following item becomes configurable when you set All LED Control to [Enabled]. 3.5.6 LCD Poster and LED Control BIOS SETUP UTILITY Advanced LCD Poster and LED Control LCD Poster Backlight [Turn Off] LCD Poster Backlight(S5) [Turn Off] LCD Poster Mode [Current... you to select which hardware information to turn on the LCD Poster. Configuration options: [All Voltage] [All Temperature] [All Fan Speed] All LED Control [Enabled] Allows you to display on /off the LCD Poster backlight when the system is in soft-off the LCD Poster...
User Guide
Page 102
... sensor cables connected to the motherboard detects device overheat to display the detected temperatures. Configuration options: [Disabled] [70ºC] [80ºC] [90ºC] �[1�0�0��ºC��] Fan Speed Monitor CPU Fan; Chassis Fan1/2; 3.6.6 Hardware Monitor Hardware Monitor Voltage Monitor Temperature Monitor Fan Speed Monitor Fan Speed Control BIOS SETUP UTILITY Power...
... sensor cables connected to the motherboard detects device overheat to display the detected temperatures. Configuration options: [Disabled] [70ºC] [80ºC] [90ºC] �[1�0�0��ºC��] Fan Speed Monitor CPU Fan; Chassis Fan1/2; 3.6.6 Hardware Monitor Hardware Monitor Voltage Monitor Temperature Monitor Fan Speed Monitor Fan Speed Control BIOS SETUP UTILITY Power...
User Guide
Page 103
... CPU temperature. Configuration options: [Standard] [Silent] [Turbo] OPTFan1/2 Control [Disabled] Allows you enable Chassis Q-Fan Control. When set the appropriate performance level of the ASUS Q-Fan. ROG Rampage II GENE 3-33 Set this item to [Silent] to minimize fan speed for quiet chassis fan operation, or [Turbo] to achieve maximum chassis fan speed. Configuration options: [Disabled] [Duty Mode] [User Mode] You...
... CPU temperature. Configuration options: [Standard] [Silent] [Turbo] OPTFan1/2 Control [Disabled] Allows you enable Chassis Q-Fan Control. When set the appropriate performance level of the ASUS Q-Fan. ROG Rampage II GENE 3-33 Set this item to [Silent] to minimize fan speed for quiet chassis fan operation, or [Turbo] to achieve maximum chassis fan speed. Configuration options: [Disabled] [Duty Mode] [User Mode] You...
User Guide
Page 104
This item appears when the OPTFan1/2 Control item is set to set the temperature at which the power fan rotates at full speed. OPTFan1/2 Duty [50%] Allows you to [Duty Mode]. Configuration options: [25˚C] [30˚C] [35˚C] [40˚C] OPTFan1/2 ...Full Speed Temp [60˚C] Allows you to [User Mode]. This item appears when the OPTFan1/2 Control item is set to set the fan duty cycle. Configuration options: [60˚C] [70˚C] [80˚C] [90˚C] 3-34 Chapter 3: BIOS setup Configuration options: [40%] [50%] [60%]...
This item appears when the OPTFan1/2 Control item is set to set the temperature at which the power fan rotates at full speed. OPTFan1/2 Duty [50%] Allows you to [Duty Mode]. Configuration options: [25˚C] [30˚C] [35˚C] [40˚C] OPTFan1/2 ...Full Speed Temp [60˚C] Allows you to [User Mode]. This item appears when the OPTFan1/2 Control item is set to set the fan duty cycle. Configuration options: [60˚C] [70˚C] [80˚C] [90˚C] 3-34 Chapter 3: BIOS setup Configuration options: [40%] [50%] [60%]...
User Guide
Page 140
...-in different geographic regions and your PC's system loading. 4.3.6 ASUS Fan Xpert Asus Fan Xpert intelligently allows you to adjust both the CPU and chassis fan speeds according to different ambient temperatures caused by different climate conditions in variety of useful profiles offer flexible controls of fan speed to cancel the Fan Xpert utility 4-24 Chapter 4: Software support
...-in different geographic regions and your PC's system loading. 4.3.6 ASUS Fan Xpert Asus Fan Xpert intelligently allows you to adjust both the CPU and chassis fan speeds according to different ambient temperatures caused by different climate conditions in variety of useful profiles offer flexible controls of fan speed to cancel the Fan Xpert utility 4-24 Chapter 4: Software support
User Guide
Page 143
... system shift modes automatically according to run Calibration first. ROG Rampage II GENE 4-27 You can select to optimize power management. Click the Drivers tab and then click ASUS EPU-Six Engine. 3. Launching 6 Engine Launch 6 Engine by configuring settings like CPU frequency, vCore Voltage, and Fan Control. Place the support DVD to complete installation. Follow the...
... system shift modes automatically according to run Calibration first. ROG Rampage II GENE 4-27 You can select to optimize power management. Click the Drivers tab and then click ASUS EPU-Six Engine. 3. Launching 6 Engine Launch 6 Engine by configuring settings like CPU frequency, vCore Voltage, and Fan Control. Place the support DVD to complete installation. Follow the...
User Guide
Page 146
... Turbo Mode options CPU Frequency vCore Voltage Downgrade Chipset Voltage Downgrade Turn Off hard disks CPU Loadline Overclocking +1% to +30% N/A N/A Never/After 3 mins-After 5 hours N/A Fan Control N/A AI Nap Idle Time Never/After 3 mins-After 5 hours High Performance Mode N/A N/A N/A Never/After 3 mins-After 5 hours N/A N/A Never/After 3 mins-After 5...Bios Setting/Quiet Never/After 3 mins-After 5 hours The TweakIt function is disabled when 6-Engine is set 6-Engine to Auto Mode. • Fan Control: Adjusts fan speeds to the following table for the configuration options in each mode.
... Turbo Mode options CPU Frequency vCore Voltage Downgrade Chipset Voltage Downgrade Turn Off hard disks CPU Loadline Overclocking +1% to +30% N/A N/A Never/After 3 mins-After 5 hours N/A Fan Control N/A AI Nap Idle Time Never/After 3 mins-After 5 hours High Performance Mode N/A N/A N/A Never/After 3 mins-After 5 hours N/A N/A Never/After 3 mins-After 5...Bios Setting/Quiet Never/After 3 mins-After 5 hours The TweakIt function is disabled when 6-Engine is set 6-Engine to Auto Mode. • Fan Control: Adjusts fan speeds to the following table for the configuration options in each mode.
User Guide
Page 161
...one CrossFireX-ready dual-GPU graphics card that are ATI® certified. • Ensure that allows you install additional chassis fans for better thermal environment. • Visit the ATI Game website (http://game.amd.com) for details. • We ...ATI® CrossFireX™ technology The motherboard supports the ATI® CrossFireX™ technology that your graphics card driver supports the ATI CrossFireX technology. ROG Rampage II GENE 5-1 Close all existing graphics card drivers before installing ATI CrossFireX graphics cards to Control Panel > Programs and Features. 3....
...one CrossFireX-ready dual-GPU graphics card that are ATI® certified. • Ensure that allows you install additional chassis fans for better thermal environment. • Visit the ATI Game website (http://game.amd.com) for details. • We ...ATI® CrossFireX™ technology The motherboard supports the ATI® CrossFireX™ technology that your graphics card driver supports the ATI CrossFireX technology. ROG Rampage II GENE 5-1 Close all existing graphics card drivers before installing ATI CrossFireX graphics cards to Control Panel > Programs and Features. 3....
User Guide
Page 174
... cacheable ranges between each 64K page. 1. Initialize the APIC for P6 class CPU & program CPU with proper cacheable range. 3. Initialize floppy controller 2. Detect serial ports & parallel ports. Debug code table Code 8254TEST 8259MSK1 8259MSK2 8259TEST COUNTMEM MP INIT USB INIT TEST MEM SHOW MP PNP...range to enter Setup utility. Assign resources to devices. 1. Detect & install co-processor New CPU installed Execute EZ Flash CPR error Fan error UCODE error Floppy error Keyboard error HDD error CMOS error Mouse error HDD smart function error Hard monitor error AI NET error Case...
... cacheable ranges between each 64K page. 1. Initialize the APIC for P6 class CPU & program CPU with proper cacheable range. 3. Initialize floppy controller 2. Detect serial ports & parallel ports. Debug code table Code 8254TEST 8259MSK1 8259MSK2 8259TEST COUNTMEM MP INIT USB INIT TEST MEM SHOW MP PNP...range to enter Setup utility. Assign resources to devices. 1. Detect & install co-processor New CPU installed Execute EZ Flash CPR error Fan error UCODE error Floppy error Keyboard error HDD error CMOS error Mouse error HDD smart function error Hard monitor error AI NET error Case...