Question posted by alpapadon on September 15th, 2023

Avr

put new avr in 2800w inverter yamaha and only getting 121volts what could be problem

Current Answers

Answer #1: Posted by Deepak0 on September 16th, 2023 4:25 AM
This answer was accepted by the poster of the original question.
Deepak0

Member since:
March 8th, 2023

Points: 2,300
1,100
points
Here are some possible reasons why you might be getting only 121 volts from your 2800w Yamaha inverter:
  • The AVR may be defective.
  • The inverter may be overloaded.
  • The inverter may not be properly connected to the battery.
  • The battery may be weak or dead.

To troubleshoot the problem, you can try the following:

  1. Check the AVR to make sure it is properly connected.
  2. Make sure the inverter is not overloaded.
  3. Check the inverter's battery connections.
  4. Test the battery to make sure it is fully charged.

If you are still having problems, you may need to consult a qualified electrician.

Here are some additional tips for troubleshooting inverter problems:

  • Make sure the inverter is turned on.
  • Check the inverter's input and output voltages to make sure they are within the specified range.
  • Check the inverter's temperature to make sure it is not overheating.
  • Check the inverter's fault indicators to see if there are any errors.
  • If you are not sure how to troubleshoot the problem, consult a qualified electrician.

Answer #2: Posted by Deepak0 on September 16th, 2023 4:25 AM
Deepak0

Member since:
March 8th, 2023

Points: 2,300
100
points
Here are some possible reasons why you might be getting only 121 volts from your 2800w Yamaha inverter:
  • The AVR may be defective.
  • The inverter may be overloaded.
  • The inverter may not be properly connected to the battery.
  • The battery may be weak or dead.

To troubleshoot the problem, you can try the following:

  1. Check the AVR to make sure it is properly connected.
  2. Make sure the inverter is not overloaded.
  3. Check the inverter's battery connections.
  4. Test the battery to make sure it is fully charged.

If you are still having problems, you may need to consult a qualified electrician.

Here are some additional tips for troubleshooting inverter problems:

  • Make sure the inverter is turned on.
  • Check the inverter's input and output voltages to make sure they are within the specified range.
  • Check the inverter's temperature to make sure it is not overheating.
  • Check the inverter's fault indicators to see if there are any errors.
  • If you are not sure how to troubleshoot the problem, consult a qualified electrician.

Related Yamaha EF2800i Manual Pages

Owners Manual - Page 3

... first three digits of these numbers are the unit production number. AE00022 EF2800i/YG2800i OWNER'S MANUAL © 2003 by Yamaha Motor Corporation, U.S.A. 1st Edition, August 2003 All rights reserved. is ...provide you in case your machine, please consult a Yamaha dealer. AE00012 IDENTIFICATION NUMBER RECORDS Record your new Yamaha. AE00011 MACHINE IDENTIFICATION The machine serial number is ...
Owners Manual - Page 5

... TROUBLESHOOTING 31 STORAGE 33 DRAIN THE FUEL 33 ENGINE 33 EXHAUST EMISSION CONTROL SYSTEM AND COMPONENTS 34 SPECIFICATIONS 35 DIMENSIONS 35 ENGINE 35 GENERATOR 35 WIRING DIAGRAM 36 EF2800i 36 YG2800i 37 AE00041 CONTENTS LIMITED WARRANTY (EF- AND EDL-SERIES 1 LIMITED WARRANTY (EC- RECEPTACLE TEST (for YG2800i 11 PRE-OPERATION CHECK 12...
Owners Manual - Page 6

... in the continental United States will be charged for this warranty to normal wear or routine maintenance. THE PERIOD OF WARRANTY Any new EFseries or EDL-series Yamaha Generator purchased for private, non-commercial use from date of time stated herein, subject to certain stated limitations. GENERAL EXCLUSIONS from this warranty shall include...
Owners Manual - Page 7

... MOTOR CORPORATION, U.S.A. AND YG-SERIES INDUSTRIAL GENERATOR LIMITED WARRANTY Yamaha Motor Corporation, U.S.A. ALSO EXCLUDED FROM THIS WARRANTY ARE ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING LOSS OF USE. SPECIFIC EXCLUSIONS from defects in warranty repairs will , free of parts or accessories that new Yamaha EC- SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF...
Owners Manual - Page 8

...cancelled if I perform any specific questions on . Be sure to bring your new address by an authorized Yamaha generator dealer for the policy to a failure? A. Since all of your dealer ...help you have purchased your new generator, please advise us of purchase. A. The unit has to repair of sale, and upon request. If a question or problem arises regarding warranty, first contact...
Owners Manual - Page 9

... SPILLED FUEL OR FUEL LEAKS. 8 STOP ENGINE BEFORE REFUELING. 8 DO NOT OPERATE NEAR FLAMMABLE MATERIALS. 8 ELECTROCUTION CAN OCCUR IF GENERATOR IS USED IN RAIN, SNOW, OR NEAR WATER. EMISSIONS COMPLIANCE PERIOD:CATEGORY A (EPA) YAMAHA MOTOR CO., LTD zzz-2179R-zz DISPLACEMENT: zzz J VALVE LASH (A) IN: z.zz~z.zz IGNITION TIMING & IDLE MIXTURE NO...
Owners Manual - Page 11

...engine with wet hands or electrical shock will occur. 741-011 9 Be sure to carry the generator only by its carrying handle(s). 1 Carrying handle(s) (shaded) 741-057 AE00083 ELECTRIC SHOCK PREVENTION ... Never touch the machine with a dust cover. q q 741-009 9 Be sure to ground (earth) the generator. 9 Keep the machine at least 1 m (3 ft) from buildings a or other equipment, or the engine ...
Owners Manual - Page 12

... switch. Backfeeding can occur when nor- ing's electrical system, a licensed electrician must install an isolation (transfer) switch in parallel with any other generator. 2 1 Correct 2 Incorrect AE00091 CONNECTION w 1 Before the generator can be protected by a tough flexible rubber sheath (IEC 245) or the equivalent to the building. Ground (earth) Lead Diameter: 0.12 mm...
Owners Manual - Page 16

... AE00848 G.F.C.I . (Ground Fault Circuit Interrupter) 1 shuts off automatically when the load exceeds the generator rated output. pens, check the equipment carefully. If this hap- If it again. If the.... cC 763-188a Reduce the load to the specified generator rated output if the DC protector turns off again, consult a Yamaha dealer. RECEPTACLE (for YG2800i) w The G.F.C.I . ...
Owners Manual - Page 17

... Fuel tank capacity: Total: 11.2 L (2.46 Imp gal, 2.96 US gal) Your Yamaha engine has been designed to use regular unleaded gasoline with any spilled fuel immediately. 9 After ... very hot after the engine has been run. w The engine and muffler will be made each time the generator is tight- Avoid touching the engine and muffler while they are still hot with a pump octane number ((R...
Owners Manual - Page 18

... ENGINE OIL Make sure the engine oil is at the upper level of the oil filler hole. cC The generator has been shipped without engine oil. Add oil as necessary. 700-108a 1 Upper level q 700-103c 0°C 25°C A YAMALUBE 4(10W-30) D SAE 10W C SAE #...
Owners Manual - Page 19

... fuel cock lever to the "3" (OFF) position. 761-073 å EF2800i ∫ YG2800i 1 3 "OFF" q 763-126b 1. B 9 Turn the economy control switch to the "ON" position. 1 "ON" q 705-037 2. Turn the engine switch to the "7" (ON) position. AE00955 OPERATION q NOTE: The generator has been shipped without engine oil. Fill with oil or it...
Owners Manual - Page 21

...Examples include some medical equipment, personal computers, and some inverters that sense peak and RMS voltage values. EX: Generator rated output 2500VA Frequency Power factor 1.0 -2350W AC ...(See page 18 for more uniform voltage supply than portable generators provide. AE01000 APPLICATION RANGE AC DC Power factor EF2800i YG2800i 1 -2,500W 0.8-0.95 -2,000W 0.4-0.75 (Efficiency ...
Owners Manual - Page 22

... current is on any electric devices are turned off before plugging it in good condition before connection to the generator. 9 Be sure any electric devices. 1 "ON" q 763-129a NOTE: The economy control switch must... economy control switch to the AC receptacle. 761-063a å EF2800i B ∫ YG2800i 761-074 4. Wind the power lead 2 or 3 turns around frame. 2. Start the engine. ...
Owners Manual - Page 23

.... 2. Reduce the total wattage of a connected electrical device is detected, the inverter control unit overheats, or the AC output voltage rises. Check for a few seconds...The AC pilot light (green) will go off any connected electric devices and stop run- NOTE: 9 The generator AC output automatically resets when the engine is not a malfunction. - 18 - Turn off and the overload ...
Owners Manual - Page 24

... damaged or obstructed. 9 Reduce the load to the specified generator rated output if the DC protector turns off again, consult a Yamaha dealer. w NOTE: q Press to the negative (-) terminal...reverse these positions. 1 Red 2 Black 2. AE00786 Battery Charging NOTE: The generator DC rated voltage is between 1.26 and 1.28. 9 Check specific gravity hourly. - 19 - Press in ...
Owners Manual - Page 28

...Hr 0 9. Generation Check the pilot light comes on. 0 15. cC Use only Yamaha specified genuine parts for further attention. - 23 - Ask an authorized Yamaha dealer for replacement... 0 14. Correct if 0 necessary. * : It is recommended that these items be serviced by a Yamaha dealer. ** : Related to emission control system. Replace if necessary. receptacle (for crack or damage. ...
Owners Manual - Page 35

...If G.F.C.I . AE01007 G.F.C.I . Receptacle 3 4 after Test Operation Pop Out 3 Correct Stay In 4 Incorrect 3. w Do not operate the generator with a faulty G.F.C.I . operates incorrectly, consult a Yamaha dealer. circuit. Have the generator repaired by a qualified mechanic. - 30 - RECEPTACLE TEST (for YG2800i) q 1. Press the test button 1, then check the position...
Owners Manual - Page 36

Clean fuel line. 2 Foreign matter in tank .... AE00785 Generator won 't start 1. Consult dealer. 4. Add engine oil. 700-006 763-084i 760-009 3. Compression Insufficient 2 Worn out piston and cylinder .... ly. 2 Damaged gasket .... Stop the ...
Owners Manual - Page 40

AE00707 GENERATOR Unit AC Output Rated Voltage V Rated frequency Hz Rated current A Rated Output kVA Safty Device: Type DC Output Rated voltage V Rated current A Safety Device: Type EF2800i/YG2800i 120 60 20...Width Overall Height Dry Weight Unit mm (in) mm (in) mm (in) kg (lb) EF2800i/YG2800i 487 (19.2) 395 (15.6) 425 (16.7) 29 (63.9) AE00704 ENGINE Type Cylinder Arrangement...

Similar Questions

I Have No Spark
Yamaha 2800i has no spa
(Posted by Mike87080 11 months ago)
Yamaha Ef2800i Generator
Hi Just started generator and have no AC power,Checked all leads and connections and still no AC.Ple...
(Posted by gamjam 2 years ago)
Yg2800i Generator Ac Light Flickers On And Off, No Output
Our 2800 generator was fine until yesterday. Now it starts and runs smoothly at a fixed speed, but t...
(Posted by knoxbox 8 years ago)
Ask a New Question
Use the box below to post a new question about this Yamaha product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Yamaha Manuals

Find free Yamaha EF2800i - Inverter Generator manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Yamaha Reviews

View thousands of Yamaha user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Yamaha customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Yamaha customer service rankings, employee comments and much more from our sister site.

Yamaha Recalls

Find comprehensive Yamaha recall information updated hourly on RecallOwl.com.