High Pressure Error

I have 4 in row cooling units and 3 of them have being giving the error "high pressure" yet they have onlly just been installed

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Tripp Lite SRCOOL33K Manual Pages

SNMPWEBCARD Firmware Version 12.06.0062 Release Notes (Supports SRCOOL33K) - Page 1

... OR LATER FOR SECURITY REASONS. WHAT'S NEW IN THIS VERSION 1) New Features * [MC-3] Added SRCOOL33K Air Conditioner Protocol and UI Support * [MC-6] Java UI Scheduling page added * [MC-44] scp...MC-271] Min-Max range of High Tx Voltage and Low Tx Voltage are lower than the Protocol UPS Specification * [MC-265] Socket read errors on installation and usage of this software distribution...
SNMPWEBCARD Firmware Version 12.06.0062 Release Notes (Supports SRCOOL33K) - Page 2

...Control scheduled actions not firing Support for sending test emails added PDUMH30ATNET reports incorrect "High Transfer Voltage" value Shed delay was successfully updated to database but Loads didn't ...data Unable to start/stop SRCOOL33K from Java UI User logged in error by guardian Memory leak in SNMP implementation Radius issues Incorrect outlet state for SRCOOL33K. COMM SETTINGS ARE 9600...
Owner's Manual for SRCOOL33K Self-Contained Air Conditioning Unit 933139 - Page 2

... unit. • Prior to operation, ensure that delivers high-efficiency precision cooling. The SRCOOL33K/ SRXCOOL33K is a self-contained air conditioning unit housed...cooling unit operates under pressure. It features an inverter-driven DC (direct current) variable-speed compressor that : • The unit has been properly installed in accordance with the procedures detailed in the Installation...
Owner's Manual for SRCOOL33K Self-Contained Air Conditioning Unit 933139 - Page 3

... cooling adjustments • Soft-start feature limits inrush current to prevent introduction of line noise, voltage disruptions and potential circuit overloads • Self-contained, zero-maintenance unit ... Web, telnet or Modbus • Row-based airflow path maximizes hot-aisle/cold-aisle efficiency and cooling predictability by supplying cold intake air high in the cold aisle and removing hot...
Owner's Manual for SRCOOL33K Self-Contained Air Conditioning Unit 933139 - Page 4

... (lb/kg) Unit dimensions (HWD/in) Unit dimensions (HWD/cm) Material of construction Color Form factor Environmental Cooling capacity (BTU) Features Dehumidifier capacity Compressor type Refrigerant (type/capacity) Air flow Amp draw Sound level (noise) Air tube length (in/cm) Warranty Standard limited warranty Optional coverage (extensions of standard warranty period) SRCOOL33K SRXCOOL33K 208...
Owner's Manual for SRCOOL33K Self-Contained Air Conditioning Unit 933139 - Page 5

... the room. The unit continuously varies the cooling output to the room at the return of the SRCOOL33K/SRXCOOL33K is installed in accordance with the Installation Manual, including stabilization and sufficient clearance around the unit. Note: Setting a lower fan speed may be set temperature at the required temperature. In-Row/Hotspot Mode: When the unit is to remove...
Owner's Manual for SRCOOL33K Self-Contained Air Conditioning Unit 933139 - Page 6

... Initial Operation To Power the Unit On 1 Make sure that alert you to modify the numerical value. Press ENT to the Installation Manual. When the SRCOOL33K/SRXCOOL33K is configured and controlled ...press ENT to menu by touching the left and right arrows. Note: The unit has a factory default cooling temperature of the unit. 5. Press SET to enter the password and press ENT to confirm. 5...
Owner's Manual for SRCOOL33K Self-Contained Air Conditioning Unit 933139 - Page 7

...unit cannot keep up with the heat load. Check for service. Call Tripp Lite for service if error remains. Call Tripp Lite for service. If error remains, call Tripp Lite for any humidification systems in the upper tray. Critical Faults Alarm Conditions Return air sensor failure Suction temperature sensor fault High discharge pressure Suction pressure... The SRCOOL33K/SRXCOOL33K...
Owner's Manual for SRCOOL33K Self-Contained Air Conditioning Unit 933139 - Page 8

...8226; Operating mode • Cooling output (estimated in kW) • Temperature of the air entering the SRCOOL33K/SRXCOOL33K • Temperature of the air leaving the SRCOOL33K/SRXCOOL33K The second sub-menu provides...compressor is drawing • Current the fans are drawing • Total current for the unit The sixth and seventh sub-menus provide the time the following components have been in ...
Owner's Manual for SRCOOL33K Self-Contained Air Conditioning Unit 933139 - Page 9

... output (Open or Closed) • What type of alarm causes the output to set high-limit alarms for: • Temperature leaving the SRCOOL33K/SRXCOOL33K • Temperature entering the SRCOOL33K/SRXCOOL33K Note: The unit alerts you to input: • Whether the unit should start automatically when...
Owner's Manual for SRCOOL33K Self-Contained Air Conditioning Unit 933139 - Page 11

.../support to an external command. Room humidity too high. Condensate drain hose not connected or not properly routed. Replace the fan. Adjust set to pump and proper routing outside of local display cable. 11 Clean coil. Adjust cooling unit's leveling feet. Heat load is excessive. Cooling unit not properly leveled. Possible Solution Disconnect communications cable...
Owner's Manual for SRCOOL33K Self-Contained Air Conditioning Unit 933139 - Page 12

...Self-Contained Air Conditioning Unit Preventive Maintenance Tripp Lite SRCOOL33K/SRXCOOL33K MONTHLY MAINTENANCE CHECKLIST Prepared By Date Model Number Serial Number General Inspection Location of cooling unit_____ Temperature setpoint_____ Room temperature/humidity near the return of environmental damage (dirt, dust, debris, liquid stains) around the unit installation area? dents or...
Owner's Manual for SRCOOL33K Self-Contained Air Conditioning Unit 933139 - Page 13

... the drain pain helps eliminate problems such as required. Tripp Lite SRCOOL33K/SRXCOOL33K SEMIANNUAL MAINTENANCE CHECKLIST Prepared By Date Model Number Serial Number Perform all Monthly Maintenance Checklist tasks PLUS the following tasks: Mechanical/Electrical Inspection Caution! Turn off the cooling unit and disconnect all Monthly Maintenance Checklist tasks PLUS the following task...
Installation Guide for SRCOOL33K Self-Contained Air Conditioning Unit 933138 - Page 1

... Connections 5 2 8. All trademarks a1re the sole property of Contents 1. RegWitsRotAeEwrRGinowRnIawSlAiwnFTNe.RRtrETtiopAEYdpTTaliIrtyiOepf.pNocroLmiate/cwhpaarornrdacunectyt Installation Manual Self-Contained Air Conditioning Unit Models: SRCOOL33K, SRXCOOL33K Table of their respective owners. Important Safety Instructions 2. Stabilization and Baying 6. Mechanical Connections...
Installation Guide for SRCOOL33K Self-Contained Air Conditioning Unit 933138 - Page 2

...IT rooms and data centers. Preparing the Installation Site The SRCOOL33K/SRXCOOL33K provides a self-contained cooling solution for supplemental cooling in a row of mains power input and can be sealed...the weight of clear floor space is positioned in the SRCOOL33K/SRXCOOL33K Unpacking Instructions and Owner's Manual. 2. The unit can receive power via hardwire connections or user supplied ...
Installation Guide for SRCOOL33K Self-Contained Air Conditioning Unit 933138 - Page 3

... to be bayed in a row of the adjoining racks. •... Baying If your application requires the SRCOOL33K/SRXCOOL33K to the adjoining rack using...high, the supply ducts should be ducted out of continuously treating heat rejected by the building cooling system or exchanged with ducts less than the intake tubes by condenser will cause the unit to shut down. 6.1 Duct Installation Install...
Installation Guide for SRCOOL33K Self-Contained Air Conditioning Unit 933138 - Page 4

... Installation in High-Humidity Environments The SRCOOL33K/SRXCOOL33K comes with a built-in length, with a bracket to stabilize the compressor during transit. Route the unattached end of the unit....reduced during periods of the unit. Install the auxiliary drain line C . The unit's cooling capacity will be similar in condensate removal system that the unit is not included with a...
Installation Guide for SRCOOL33K Self-Contained Air Conditioning Unit 933138 - Page 6

... all safety instructions and codes before proceeding. Once the unit has been properly hardwired and powered on the unit. Aways connect plugs to a power strip or surge suppressor. All wiring should be hardwired at either point of mains power input. 1 If it was installed, remove the power cord assembly from the point of...
Installation Guide for SRCOOL33K Self-Contained Air Conditioning Unit 933138 - Page 8

Additional Contact Connections The SRCOOL33K/SRXCOOL33K includes an additional set to 0 (No) the unit will only annunciate an alarm when the input is a critical alarm that causes the unit to stop cooling. This contact is actively cooling. A P1 P2 P3 P4 P5 P6 P7 P8 EPO / Remote Shutdown / Alarm Input P3 and P4 provide a digital input...
Unpacking Instructions for SRCOOL33K Self-Contained Air Conditioning Unit 933140 - Page 1

...or move the unit without the assistance of the unit. X2 SIDE VIEW 4 5 6 Copyright © 2013 Tripp Lite. Do not push or pull the unit while unpacking. SRCOOL33K & SRXCOOL33K ...installation site before unpacking it has been damaged or mishandled. 2 Cut the plastic straps on the outside of the cabinet match the unit you secure the ramps to remove the unit from the cooling unit...

Similar Questions

Error Code
What does it mean upon powering up the unit, its showing "88" on the display
(Posted by paulfong 7 months ago)
Tried The Recommended Solution For The Error Code E2. No Improvement.
model #SRCOOL12K - What can i do next????
(Posted by hlwarner1 7 years ago)
I Bought A Tripp Lite Srcool12k Portable Cooling
I bought a Tripp Lite SRCOOL12K Portable Cooling / Air Conditioner Stand Alone Spot Air Cooler 120V,...
(Posted by billgraves 7 years ago)
On A Tripp Lite Srcool12k Code P1
On a Tripp Lite SRCOOL12K... What doses P1 mean when it comes up on the digital readout also it beep...
(Posted by michlhill11 8 years ago)
Ask a New Question
Use the box below to post a new question about this Tripp Lite product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Tripp Lite Manuals

Find free Tripp Lite SRCOOL33K manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Tripp Lite Reviews

View thousands of Tripp Lite user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Tripp Lite customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Tripp Lite customer service rankings, employee comments and much more from our sister site.