Get support for Sharp ER-A450T

Sharp ER-A450T Support Question

Sharp ER-A450T Support Question

Find answers below for this question about Sharp ER-A450T.
Need a Sharp ER-A450T manual? We have 3 online manuals for this item!
Question posted by betterbusinessmachines on May 8th, 2014

The Rs232 Ports On My Ecr Have Stopped Communicating. How Can I Fix This?

The person who posted this question about this Sharp product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Sharp ER-A450T Manual Pages

Programmer Manual - Page 1

The contents are subject to be used SHARP CORPORATION for after sales service only. PROGRAM (PGM2/PGM1) MODE 17 CHAPTER 3. OP X/Z, X1/Z1, X2/Z2 MODE 44 This document has been published to change without notice. SERVICE (SRV) MODE 1 CHAPTER 2. ELECTRONIC CASH REGISTER MODEL ER-A450T (For "U" & "A" version) SRV KEY : LKGIM7113BHZZ PRINTER : PR-45M CONTENTS CHAPTER 1.
Programmer Manual - Page 7

... 38400 903-A 2 3 4 5 5 6 The communication speed with the ER-02FD is zero Print Skip Print Skip 905-B 0 5 1 4 5 #905-C, D: Not used (Fixed at "00") #903-D: 1. Type of date 1.... on X/Z report. 1. Tax is 19200 bps max. #903-B, C: Not used (Fixed at "0") #901-B: 1. ECR data copy baud rate 1. Tax system Auto tax 1-4 & manual tax CANADIAN TAX 901-B 05 6 #901-C:...
Programmer Manual - Page 17

... X: 0 = English text 2 = French text When this job is executed, below texts are connected by RS232. ER-A450T Channel No. Channel No. [JOB#996, 998] RAM DATA BACKUP function (ECR ECR, ECR ER-02FD) [JOB#996] RAM data send All data Send to ECR or ER-02FD 996 @/FOR X CA/AT (Baud rate setting:#903-A) SBTL Send to the RS...
Programmer Manual - Page 39

... C,D:Not used for Barcode reader No Channel No. (1 or 8) A 0 1 or 8 B,C,D: Not used (Fixed at "000") X:3 A: Not used (Fixed at "0") X: 2 MRS = 0000 A: Channel No. The RANGE-2 type JOB# means "6 steps". for Scale No .... 24 characters MRS = "SPACE" "SPACE" "SPACE" [JOB#2690] THE ASSIGNMENT OF RS232 FUNCTION BY EACH DEVICE 0 2690 @/FOR X @/FOR ABCD SBTL CA/AT CAUTION: Do ...
Programmer Manual - Page 40

...X: Parity bit X Even 0 Odd 1 Non 2 Y: Stop bit Y 2 bits 0 1 bit 1 Z: Transmission speed Z 4800 bps 0 9600 bps 1 19200 bps 2 MRS = 1110(For ER-A6HS1) [Job# 2710] TAX TABLE PROGRAMMING 2710 @/FOR ...to 999.99 (This is 0. Channel No.: 0 = No connection 1 = Standard port 2 2-7 = Not used by the ECR at any one time. DEPRESSION OF THE ST KEY AT FOLLOWING POINTS WILL RESULT IN...
Service Manual - Page 1

... and performance of the set . This document has been published to be used SHARP CORPORATION for maintaining the safety of the set . SERVICE MANUAL ELECTRONIC CASH REGISTER MODEL ER-A450T SRV Key : LKGIM7113RCZZ PRINTER : PR-45M ("U" and "A" version) CAUTION EXTREME CAUTION MUST BE TAKEN WHEN SERVICING THIS MACHINE. WHEN THE MODE SWITCH IS IN...
Service Manual - Page 5

.... If you want to connect an RS232 device to the ECR with the No.9 pin of the port 1 (or 2) set to +5V, make sure the AC cable of the SW2 (initial value: /CI signal) NOTE: Optional bar code reader: When connecting an ER-A6HS1, connect it to the Port 1 (or 2) and switch the No.9 pin...
Service Manual - Page 9

CHAPTER 4. HARDWARE DESCRIPTION 1. Hard ware block diagram DRAWER CPU STA NDARD RAM1 256KB OPTIONAL RAM2 ER-03RA:512KB 512KB TPRC1 GATE ARRAY MPCA7 PRINTER PR-45M OPC2 STA NDARD ROM 512KB CKDC8 RS232 I/F 1 ports OPERATER DISPLAY 1 LINE 7SEG 10DIG CUSTOMER DISPLAY 1 LINE 7SEG 7DIG SWITCH KEY BOARD RS232 I/F CH1 Fig. 1-1 4 - 1
Service Manual - Page 11

... P17 P16 P15 P14 P13 P12 P11 P10 Port 2 2) Block diagram Data bus Port 1 EXTAL XTAL X E MD2 MD1 MD0...running timer x 2ch 8bit timer Serial communication interface x 2ch Port 8 Port 7 Port 6 Data bus (Lower) Data bus (Upper) Address bus Address bus Port 4 Port 3 P27/A23 P26/A22 P25/A21...BACK WAIT P47 FTI2 P45 FTI1 P43 P42 P41/TMCI P40 Port 5 TXD2 RXD2 TXD1 RXD1 SCK2 IRQ2 IRQ1 IRQ0 P73 AN2 ...
Service Manual - Page 12

...P56 72 P57 73 P60 /NEJ NU /NER VSS TRG1 /PSTOP /CKDCR2 OPDS FVPON FMRS /SLIPLMP /STOP /ERS 74 P61 75 P62 76 P63 77 P64 /DRS /CSS /CDS /RR 78 P65 /RSS 79...OUT ER signal for RS232 (Equipment Ready) IN DR signal for RS232 (Data set Ready) IN CS signal for RS232 (Clear to Send) IN CD signal for RS232 (Carrier Detect) OUT RR signal for RS232 (Ready to Receive) (Nu) OUT RS signal for RS232 ...
Service Manual - Page 24

...off program to save the data in the CPU registers in most cases. 2) CKDC8 oscillation circuit 40 X2...19MHz which is monitored at a time of the ECR, the power supply condition is primarily used during power...159 160 I ID IS ISU IO 3S ON6 Name ER-A770 I/O VCC VCC GND GND /CSD VCC IS...TTL Schmidt input TTL Schmidt input with the signal STOP forced low to prepare for the power-off and ...
Service Manual - Page 29

... STH SCK RESET HTS STH SCK RES1 CPU P11 P10 P12 RES LDRQ ERC SHEN P-OFF LDRQ ECR SHEN POFF VDD RES0 RES0 ST0~ST7 KR0~KR7 KR10,KR11 Key board G1~G10 a~g,DP Display ...performs a mode scan and key scan at and reads the start condition (1 byte). After being cancelled, the CPU initializes each port, the CPU reads the start condition. Step No. 1 2 3 4 A ON ON OFF OFF Phase B C OFF OFF...
Service Manual - Page 38

... first 8) Line level: RS232 level 9) Data forma: LSB MSB b1 b2 b3 b4 b5 b6 b7 P Start bit FIg. 2-1 Parity bit Stop bit 3. General RAM data can be transmitted in the following two methods. Save the data before servicing as follows: ECR ECR • Cable: 9 pin D-SUB - 9 pin D-SUB ECR ECR Fig. 1-1 ECR ER-02FD • Cable: 9 pin...
Service Manual - Page 39

...transfer of the cable. END record 30 30 30 30 2 34 1 End message: Fixed to be transmitted in ASCII number. Application specification The following format: 1 2 Data (... : FRAME GROUND Fig. 3-2 4. Data format A single byte image of the memory to 30303030. ECR-ER-02FD cable 25PIN D-SUB ER-02FD SD 2 9PIN D-SUB ECR 3 SD RD 3 RTS 4 DCD 8 2 RD 7 RTS 1 DCD DTR 20 4 DTR ...
Service Manual - Page 41

... the RS-232 interface of the ER-A450T to "9" 2 ALL RAM Data UpLoad ( ER-A450T -> PC ) 3 "Execute "02FD.EXE" on ER-A450T side 2 Place the SRV key in the SRV mode. 4 Set the Communication method by RS232. side 1 Install "02FD.EXE" on P.C. Push "OK" Button. 5 Push "POS -> PC" Button. And Select the Receiving File. 6 - 4 ER-A450T No Procedure on the P.C. Channel...
Service Manual - Page 43

...E33 The current cashier code should not be taken when removing the TOP CABINET After removing the ER-A450T's TOP CABINET, put the TOP CABINET upright on the base, as shown below . Replace joumal...within a limit of undefined vendor coupon UPC E86 Communication error at ECR copy E87 Data format error at ECR copy E88 Time out error at ECR copy E94 Age verification error 2. E08 Insert slip...
Dealer Knowledge Book - Page 3

RECOMMENDED SEQUENCE FOR THE ER-A450T SETUP 1. Optional RAM, etc.) prior to the applicable Service Manual) 3. Designs and... to the settings for the desk top, communications ports, etc. Introduction INTRODUCTION This document will help you are subject to change without notice. This documentation assumes that will make your programming sessions by executing one of the ER-A450T Scanning ECR.
Dealer Knowledge Book - Page 8

... @/ FOR CA/AT 4 SBTL (Auto baud rate detection - SRV job#903-A) Designs and specifications are subject to port-2 (Channel #1) of the ER-A450T as shown below: X Channel No.: Port 1(CH8) Channel No.: Port 2(CH1) 3 When using the SIO Function. (1) Connection at the ER-A450T; The Program Back up/Restore (SIO) function has been fixed to change without notice.
Dealer Knowledge Book - Page 13

... specifications, the image will automatically appear so to verify the settings as follows; (1) Select the required Baud Rate, Protocol and Communications port for the PC. (When the [ CA/AT ] is used at the ER-A450T) (When the [ SBTL ] is the correct graphics, then click the [ Send ] button to initiate sending the image to the...
Dealer Knowledge Book - Page 18

...SIO(Manual) Com Port: Com1 or Com2... correct one and click [ Send ] 9 Set the communications settings as follows; Step PC Side 1 Connect the PC to the ER-A450 Step ER-A450T Side 2 Set SRV Job #903-A: "6" (38,400... bps ) 3 Set SRV job #912-D: "1, 2, 4, or 5" 4 Launch the LOGOCONV.exe at the PC 5 Select Send LOGO1 or LOGO2 to the ECR...

Similar Questions

How To Fix The Problem Of Over Limit Sign Of Sharp Cash Register Model No. Er-a5
how to fix a problem of over limit sign on cash register of sharp of model no.ER-A520
(Posted by parinpatel0033 5 years ago)
Sharp Cash Registers Pos Er-a750
two cash registers the master reads ram error the second register blank screan key boards do nothing...
(Posted by Dearl001 8 years ago)
Ask a New Question
Use the box below to post a new question about this Sharp product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Sharp Manuals

Find free Sharp ER-A450T manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Sharp Reviews

View thousands of Sharp user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Sharp customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Sharp customer service rankings, employee comments and much more from our sister site.