Get support for Sharp CVP12PX - Ha Sh 11500 Btu Portable Air Conditioner

Sharp CVP12PX Support Question

Sharp CVP12PX Support Question

Find answers below for this question about Sharp CVP12PX - Ha Sh 11500 Btu Portable Air Conditioner.
Need a Sharp CVP12PX manual? We have 1 online manual for this item!
Question posted by mail95486 on August 25th, 2010

Turns Off Tree Lights Flashing

TURNS OFF 

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Sharp CVP12PX Manual Pages

CV-P12PX | CV-P13PX | CV-PD13PX Operation Manual - Page 3

... OPERATION E-30 • DRAINAGE E-30 • MAINTENANCE E-31 • BEFORE CALLING FOR SERVICE E-32 Declaration of Conformity SHARP ROOM AIR CONDITIONER CV-P12PX,CV-P13PX,CV-PD13PX This device complies with Part 18 of your new air conditioner. Please read this manual carefully before using the product. Sharp Plaza, Mahwah, New Jersey 07430-2135 TEL: 1-800-BE-SHARP E-1
CV-P12PX | CV-P13PX | CV-PD13PX Operation Manual - Page 5

... to make any warranties beyond the time period described herein on behalf of Sharp. The limited warranty described herein is authorized to Obtain Service: CV-P12PX,CV-P13PX,CV-PD13PX Portable Air Conditioner. The warranty period continues for a total of five (5) years from defective workmanship and materials, and agrees that this Sharp brand product (the "Product"), when...
CV-P12PX | CV-P13PX | CV-PD13PX Operation Manual - Page 6

... between the room air conditioner and radio/TV receiver. • Connect the room air conditioner into the socket and make sure the electrical box is fully grounded. a burning smell), turn it in water.... the event of an electrical short circuit, grounding reduces the risk of this room air conditioner should cause interference to radio or television reception, try to whether the appliance is ...
CV-P12PX | CV-P13PX | CV-PD13PX Operation Manual - Page 7

.... • In the event of a power failure during use , especially if using gas appliances. • Be sure to turn the air conditioner off and immediately restart it, allow 3 minutes before restarting the unit. If you turn the unit off . Accordingly, the same amount of particularly adverse weather. When water tank inside the unit to...
CV-P12PX | CV-P13PX | CV-PD13PX Operation Manual - Page 8

... below. PRECAUTIONS OPERATING CONDITIONS • The air conditioner must remove the heat produced by your air conditioner work harder and less efficiently. • Turn off unnecessary lights. The less time the air conditioner is performed at high room temperature, the fan may run at least 12" (30cm) of air, making your lights or other heat-producing appliances. Keeping the...
CV-P12PX | CV-P13PX | CV-PD13PX Operation Manual - Page 9

...medium size Phillips) 2. Knife or scissors 4. ENGLISH INCLUDED CV-P12PX / CV-P13PX Exhaust hose Rain deflector Washer 1 assembly 1 4 ...screen 1 1 Window panel assembly Large wood screw 3 Screw Remote control 5 1 Battery 2 (AAA.1.5V) 2 CV-PD13PX Exhaust hose Rain deflector Washer 2 assembly 2 8 Window exhaust Window slider Bolt adapter 2 bracket 2 8 Exhaust ...
CV-P12PX | CV-P13PX | CV-PD13PX Operation Manual - Page 10

...4 4 POWER Button 5 5 Remote control signal 6 receiver window 7 6 OPERATION Lamp (red) 8 7 TIMER Lamp (orange) 9 8 MEGA COOL Lamp (green) 0 9 PLASMACLUSTER 0 Lamp (blue) 0 Air inlet REAR VIEW CV-PD13PX(Dual Duct use) CV-P12PX CV-P13PX CV-PD13PX(Single Duct use) q q Exhaust air outlet w e w Window exhaust adapter e Exhaust hose adapter A r t r Exhaust hose y t Remote control hook...
CV-P12PX | CV-P13PX | CV-PD13PX Operation Manual - Page 11

ENGLISH REMOTE CONTROL 1 2 3 4 5 6 7 8 9 0 q w e r t 1 Transmitter 2 Display 3 POWER Button 4 LIGHTS Button 5 TEMPERATURE Button 6 PLASMACLUSTER Button 7 SLEEP Button 8 MODE Button 9 ON TIMER Button 0 FAN Button q OFF TIMER Button w CANCEL Button e LOUVERS Button r RESET Button t MEGA COOL ...
CV-P12PX | CV-P13PX | CV-PD13PX Operation Manual - Page 12

INSTALL WINDOW PANEL Installation in a double-hung sash window (CV-P12PX, CV-P13PX) 1 Cut the foam seal A to the proper length and attach it to the window panel inside opening. Use 2 screws to attach the protective screen ...
CV-P12PX | CV-P13PX | CV-PD13PX Operation Manual - Page 14

INSTALL WINDOW PANEL Installation in a double-hung sash window (CV-PD13PX) 1 Cut the foam seal A to the proper length and attach it to the window panel inside opening. Window exhaust adapter Inside 4 Install 2 rain deflectors ...
CV-P12PX | CV-P13PX | CV-PD13PX Operation Manual - Page 16

INSTALL WINDOW PANEL Installation in a sliding sash window (CV-P12PX, CV-P13PX) 1 Cut the foam seal A to the proper length and attach it to attach the rain deflector onto the window panel. 5 Install the window panel ...
CV-P12PX | CV-P13PX | CV-PD13PX Operation Manual - Page 20

... exhaust adapter in place. Extend both ends of the exhaust hose (CV-P12PX, CV-P13PX) 1 Attach the exhaust hose adapters A and B to each other. Insert the two projections on the exhaust hose adapter B into the exhaust hose adapters A and B respectively, and turn it must not be as short as possible for operational efficiency; however...
CV-P12PX | CV-P13PX | CV-PD13PX Operation Manual - Page 21

... Insert the exhaust hose adapter A to the window exhaust adapter in the window panel and turn them to the unit in place. Exhaust hose adapter A Window exhaust adapter 4 Attach the ... adapter B Cover Projection Projection Hole 3 Attach the exhaust hoses. ENGLISH Installation of the exhaust hose (CV-PD13PX) 1 Attach the exhaust hose adapters A and B to the unit. Hole Insert the two ...
CV-P12PX | CV-P13PX | CV-PD13PX Operation Manual - Page 26

... this mode, the air conditioner dehumidifies the room. COOL DEHUM FAN VENT 2 2 Press the power button to start operation. 3 • The red OPERATION lamp on the unit will light. 3 Press the ...light. • The temperature cannot be 1 changed. AUTO QUIET LOW HIGH TO TURN OFF Press the POWER button again. • The red OPERATION lamp on the unit will turn off . TO TURN...
CV-P12PX | CV-P13PX | CV-PD13PX Operation Manual - Page 27

..., the air conditioner ventilates the air to outdoors. VENTILATION MODE In this mode, the air conditioner simply circulates the air without cooling it. COOL DEHUM FAN VENT 2 2 Press the POWER button to set the desired fan speed. QUIET LOW HIGH 3 TO TURN OFF Press the POWER button again. • The red OPERATION lamp on the unit will light...
CV-P12PX | CV-P13PX | CV-PD13PX Operation Manual - Page 29

... . TO CANCEL 1 Press the PLASMACLUSTER button again. • The PLASMACLUSTER lamp on the air conditioner. • To turn off the PLASMACLUSTER Lamp, press the LIGHTS button. • PLASMACLUSTER operation cannot be activated the next time you turn on the unit will light. E-27 ENGLISH PLASMACLUSTER OPERATION Plasmacluster ions released into the room will reduce some airborne...
CV-P12PX | CV-P13PX | CV-PD13PX Operation Manual - Page 30

... is started, the temperature setting rises by an additional 2˚F. Only the most recent settings will light. NOTES: • You cannot set the temperature or fan speed during cooling mode. • The...8226; The orange TIMER lamp on the unit will turn off. MEGA COOL OPERATION In this operation, the air conditioner fan works at extra high speed with a setting temperature of...
CV-P12PX | CV-P13PX | CV-PD13PX Operation Manual - Page 31

... The orange TIMER lamp on the remote control display the next time you can not be cancelled and will turn off . OFF TIMER 1 Press the OFF TIMER button and set the time as follows. TO CANCEL TIMER...the settings. 0.5h 1.0h 1.5h 10h 11h 12h • The orange TIMER lamp on the unit will light. • The time setting will change the setting, the unit will count down to show the remain-...
CV-P12PX | CV-P13PX | CV-PD13PX Operation Manual - Page 32

...drain water within the unit in the cooling mode, set to the drainpipe. TO TURN OFF Press the POWER button again. • The red OPERATION lamp on the unit will light. • If the unit has not been unplugged since it was last operated,...not available. 1 1 Press the POWER button on the unit. • The red OPERATION lamp on the unit will turn off. The fan speed set at 68˚F.
CV-P12PX | CV-P13PX | CV-PD13PX Operation Manual - Page 34

... minutes of the refrigerant flowing inside the unit is generating Plasmacluster ions. • This air conditioner evaporates water condensed during operation. Place the unit on a gently sloping floor. THE UNIT...the unit is turned on or off , preventing cooling for less than 3 minutes when, you restart the unit within the unit through the exhaust air outlet. THE DISCHARGED AIR HAS AN ODOR...

Similar Questions

Ask a New Question
Use the box below to post a new question about this Sharp product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Sharp Manuals

Find free Sharp CVP12PX - Ha Sh 11500 Btu Portable Air Conditioner manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Sharp Reviews

View thousands of Sharp user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Sharp customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Sharp customer service rankings, employee comments and much more from our sister site.