Question posted by Anonymous-138634 on June 21st, 2014

How Can I Change To Maga Cool Without A Remoto

How can I change to maga cool without a remoto

Current Answers

Answer #1: Posted by TechSupport101 on June 22nd, 2014 1:31 AM
This answer was accepted by the poster of the original question.
TechSupport101

Member since:
May 24th, 2013

Points: 12,171,305
1,100
points
Hi. It may not be possible without a remote - refer to the 'Mega Cool Operation' section of the Operaion Manual here http://www.helpowl.com/manuals/Sharp/CVP09LX/16067

Related Sharp CVP09LX Manual Pages

CV-P09LX , CV-P10LC , CV-P10MX , CV-P12LX Operation Manual - Page 3

... • TO CHANGE AIR FLOW DIRECTION E-23 • PLASMACLUSTER OPERATION E-24 • MEGA COOL OPERATION E-25 • ONE-HOUR OFF TIMER E-25 • TIMER OPERATION E-26 • MAIN UNIT OPERATION E-28 • DRAINAGE E-29 • MAINTENANCE E-30 • BEFORE CALLING FOR SERVICE E-31 Declaration of Conformity SHARP ROOM AIR CONDITIONER CV-P09LX, CV-P12LX, CV-P10LC, CV-P10MX This...
CV-P09LX , CV-P10LC , CV-P10MX , CV-P12LX Operation Manual - Page 5

...liabilities and responsibilities of Sharp. labor and service are not provided free of change for this Product: Additional Item(s) Excluded From Warranty Coverage (If any damages... the Sealed Cooling System parts; Contact your home, and if it . The Servicer will come to your Sharp Authorized Servicer to Obtain Service: CV-P09LX, CV-P12LX, CV-P10LC or CV-P10MX Portable Air Conditioner.
CV-P09LX , CV-P10LC , CV-P10MX , CV-P12LX Operation Manual - Page 7

... (h) Any products used for this warranty on contract, negligence, strict liability or otherwise. WARRANTY PERIODS: Audio Products Camcorder DVD Products Projector LCD TV Microwave Oven Air Purifier Portable Air Conditioner Parts & Labour (exceptions noted) 1 year 1 year 1 year 1 year (lamp 90 days) 1 year 1 year (magnetron component-4 additional years) 1 year 1 year To obtain the name and...
CV-P09LX , CV-P10LC , CV-P10MX , CV-P12LX Operation Manual - Page 9

... plug can cause electrical shock or equipment damage. • Drainage should be performed whenever moving the air conditioner. (See Page 29) If any water remains in the tank, it may spill out while being... splash or pour water directly onto the unit. Drained water may be grounded. Cooling performance may freeze inside the hose, causing water inside the unit to overflow into the room. ...
CV-P09LX , CV-P10LC , CV-P10MX , CV-P12LX Operation Manual - Page 10

... three minutes for safety. • In the event of a power failure during dehumidification mode and the room temperature will prevent cooling for the compressor to a higher temperature will blink. Your air conditioner must be canceled and the unit will enter the room from outside the room via the exhaust hose while in safety...
CV-P09LX , CV-P10LC , CV-P10MX , CV-P12LX Operation Manual - Page 12

...5 Remote control signal receiver 6 window 7 6 POWER Button 8 7 OPERATION Lamp (red) 9 0 8 TIMER Lamp (orange) 0 9 MEGA COOL Lamp (green) 0 0 Air inlet REAR VIEW q q Exhaust air outlet w w Window exhaust adapter e e Exhaust hose r r Remote control hook t t Air filters y u y Drainage nozzle and stopcock u Power supply cord hooks i Drainpipe nozzle and stopcock i o Power...
CV-P09LX , CV-P10LC , CV-P10MX , CV-P12LX Operation Manual - Page 13

... 8 MODE Button 9 ON TIMER Button 0 FAN Button q OFF TIMER Button w CANCEL Button e LOUVERS Button r RESET Button t MEGA COOL Button REMOTE CONTROL DISPLAY y y MODE SYMBOLS : COOL : DEHUMIDIFICATION u p : FAN : VENTILATION i a u MEGA COOL SYMBOL i PLASMACLUSTER SYMBOL o s o FAN SPEED SYMBOLS : AUTO : Manual setting p TEMPERATURE AND TIMER COUNT DOWN INDICATOR a TRANSMITTING SYMBOL...
CV-P09LX , CV-P10LC , CV-P10MX , CV-P12LX Operation Manual - Page 18

... possible for operational efficiency; Window exhaust adapter Extend Exhaust hose Projection Hole "TOP" The exhaust hose should be twisted or bent. however, it (approx. MODE COOL, FAN, VENTILATION, DEHUMIDIFICATION with no container DEHUMIDIFICATION with the usage mode. three times) until it is installed in a double-hung sash window. Unacceptable Acceptable Acceptable...
CV-P09LX , CV-P10LC , CV-P10MX , CV-P12LX Operation Manual - Page 20

... the ± and - The circuit breaker is activated, power is supplied, and the air conditioner is now ready for a prolonged period, remove the batteries from the remote control. polarities are...-OPERATION CHECKS POWER PLUG CHECK This air conditioner uses a fused power plug. Always check the power plug before use . • When replacing the batteries, always change both batteries at the back of ...
CV-P09LX , CV-P10LC , CV-P10MX , CV-P12LX Operation Manual - Page 22

... CLOSE position, Drainage nozzle and check the drainage nozzle is covered "CLOSE" position with the stopcock. COOL MODE 1 Install the exhaust hose (See Page16), turn off. COOL DEHUM FAN VENT 32 Press the POWER button to start operation. • The red OPERATION lamp on... can be set within the range 3 of 64°F to 86°F. 1 4 4 Press the FAN button to select COOL mode.
CV-P09LX , CV-P10LC , CV-P10MX , CV-P12LX Operation Manual - Page 23

... during dehumidification mode and the room temperature will light. • The temperature cannot be changed. 1 TO TURN OFF Press the POWER button again. Do not operate in the container... the TIMER, OPERATION and MEGA COOL lamps are blinking, depending on the unit will become less effective than 8 hours at a time. In this mode, the air conditioner dehumidifies the room. nozzle, and...
CV-P09LX , CV-P10LC , CV-P10MX , CV-P12LX Operation Manual - Page 24

... cannot be set the desired fan speed. • Although the louvers are closed and no air blows out into the room, the external ventilation fan speed changes. VENTILATION MODE In this mode, the air conditioner simply circulates the air without cooling it. Press the FAN button to select VENT mode. Install the exhaust hose (See Page16...
CV-P09LX , CV-P10LC , CV-P10MX , CV-P12LX Operation Manual - Page 25

...Press the LOUVERS button again when the horizontal louvers are at the lowest position in the COOL or DEHUMIDIFICATION mode for an extended period of time, condensation may form on the remote... to the extreme left or right in the diagram and adjust the air flow direction. ENGLISH TO CHANGE AIR FLOW DIRECTION UP / DOWN AIR FLOW DIRECTION 1 Press the LOUVERS button on the louvers. E-23 ...
CV-P09LX , CV-P10LC , CV-P10MX , CV-P12LX Operation Manual - Page 27

...the unit will light. Alernatively, turn the unit off . ENGLISH MEGA COOL OPERATION In this operation, the air conditioner fan works at the formerly set condition. • If you wish ...CANCEL Press the MEGA COOL button again. 1 • MEGA COOL operation is also cancelled when the mode is changed, or when the unit is set the temperature or fan speed during cooling mode. • ...
CV-P09LX , CV-P10LC , CV-P10MX , CV-P12LX Operation Manual - Page 28

... to 9.5 hours, you can set , the TIMER setting will be cancelled and will not be set the time as desired. • The time setting will change as you set the OFF TIMER or ON TIMER. • The OFF TIMER and ON TIMER can be cancelled. • If a power failure occurs while...
CV-P09LX , CV-P10LC , CV-P10MX , CV-P12LX Operation Manual - Page 29

...signal receiver window on the unit. 1 Press the ON TIMER button. • The time setting will change as you press the button as desired. • When the temperature is set with the ON TIMER,... PLASMACLUSTER operation as follows. 0.5h 1.0h 1.5h 10h 11h 12h 1 Display shown when you do not change the setting, the unit will turn off. maining time. Timer duration can set in the display for 5...
CV-P09LX , CV-P10LC , CV-P10MX , CV-P12LX Operation Manual - Page 30

... remote control is not available. 1 Press the POWER button on the unit. • The red OPERATION lamp on the unit will resume operation in the cooling mode, set to AUTO. TO TURN OFF Press the POWER button again. • The red OPERATION lamp on the unit will light. 1 • If the...
CV-P09LX , CV-P10LC , CV-P10MX , CV-P12LX Operation Manual - Page 31

...that may be drained out is approximately 41/5 pints. • The OPERATION, TIMER and MEGA COOL Hose lamps will take about one minute. 4 Remove the hose from the drainage nozzle, and...out through the hose during operation. If the unit stops operating and the TIMER, OPERATION and MEGA COOL lamps are blinking. (This indicates that may be drained out is approximately 41/5 pints. •...
CV-P09LX , CV-P10LC , CV-P10MX , CV-P12LX Operation Manual - Page 32

... dangerously damage the electrical insulation. CLEANING THE INSECT GUARD NET The cooling performance may result in poor cooling performance. MAINTENANCE Be sure to disconnect the power from the window ...the filter handle and gently push the filter back into place. Insect guard net MAINTENANCE AFTER AIR CONDITIONER SEASON 1 Perform drainage to drain out water within the unit. (See Page 29 "...
CV-P09LX , CV-P10LC , CV-P10MX , CV-P12LX Operation Manual - Page 33

... heard for about 5 minutes. • Are the OPERATION, TIMER and MEGA COOL lamps blinking? It must not be twisted or bent. Run the air conditioner in these modes. If the power was off for about a minute upon starting -up and is restored. Change the MODE setting. • Are the filters clogged with the polarities...

Similar Questions

Sharp Cvp09lx - 9000
fan volume is very low. cooling room almost imposible. Why is fan air volume so weak. Have cleaned f...
(Posted by itrinidad7 10 years ago)
Where To Buy Sharp Air Parts
Anyone recommend a suplier of inexpensive parts for my Sharp portable window air conditioner. I am l...
(Posted by maliburon 11 years ago)
Ask a New Question
Use the box below to post a new question about this Sharp product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Sharp Manuals

Find free Sharp CVP09LX - 9000 BTU Portable Air Conditioner manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Sharp Reviews

View thousands of Sharp user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Sharp customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Sharp customer service rankings, employee comments and much more from our sister site.