Question posted by gregbarv on January 22nd, 2014

How To Turn On Mega Cool On Sharp Air Conditioner Without Remote

The person who posted this question about this Sharp product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Sharp CV10NH Manual Pages

CV-10NH Operation Manual - Page 3

... • MEGA COOL OPERATION E-22 • ONE-HOUR OFF TIMER E-22 • TIMER OPERATION E-23 • MAIN UNIT OPERATION E-25 • DRAINAGE E-26 • MAINTENANCE E-27 • BEFORE CALLING FOR SERVICE E-28 E-1 Please read this manual carefully before using the product. ENGLISH ENGLISH This manual explains the proper use of your new air conditioner.
CV-10NH Operation Manual - Page 5

...Cooling System parts; One (1) year parts and labor from date of all claims, whether based on how long an implied warranty lasts, so the above exclusion may not apply to the servicer. Nor shall Sharp...described herein, or to Obtain Service: CV-10NH Portable Air Conditioner. ENGLISH CONSUMER LIMITED WARRANTY CONSUMER LIMITED WARRANTY FOR THE U.S. THIS WARRANTY GIVES YOU SPECIFlC ...
CV-10NH Operation Manual - Page 6

... or television reception, try to correct the interference by manufacture's service agent in mind when using the air conditioner. • Always conduct a "Power Plug Check" (See Page 16) before use a fuse with the air conditioner (ex. a burning smell), turn it in place of a proper fuse. • In the event of the unit. • Ensure the...
CV-10NH Operation Manual - Page 7

...This appliance must have no kinks or be grounded. Cooling performance may be plugged into a socket that has ...be on a differ- The plug must not be performed whenever moving the air conditioner. (See Page 26) If any doubt as to whether the appliance is...use , especially if using gas appliances. • Be sure to turn the unit off and disconnect the power supply cord before perform- ...
CV-10NH Operation Manual - Page 8

... TIPS • Avoid direct sunlight. Turn off any openings into the room. • When cooling operation is reinstated, restart the air conditioner. This protective device will enter the ... operating and TIMER, OPERATION and MEGA COOL lamps will prevent it , allow 3 minutes before restarting the unit. If you restart the air conditioner within the temperature range indicated below...
CV-10NH Operation Manual - Page 9

ENGLISH LOCATION • The air conditioner should only be placed within reach of a properly rated grounded socket. • Never place any obstacles around the air inlet or outlet of the unit. • Allow at ...down in size because the window is too narrow for efficient air-conditioning. Use caution when rolling on smooth, flat least 12" (30cm) of space from...
CV-10NH Operation Manual - Page 10

... control signal receiver 4 window 5 5 POWER Button 6 6 OPERATION Lamp (red) 7 7 TIMER Lamp (orange) 8 9 8 MEGA COOL Lamp (green) 9 9 Air inlet 9 REAR VIEW 0 0 Exhaust air outlet q q Window exhaust adapter w w Exhaust hose e e Remote control hook r t r Air filters y t Drainage nozzle and stopcock y Power supply cord hooks u Drainpipe nozzle and stopcock u i Power...
CV-10NH Operation Manual - Page 11

... OFF Button 6 MODE Button 7 ON TIMER Button 8 FAN Button 9 OFF TIMER Button 0 CANCEL Button q LOUVERS Button w RESET Button e MEGA COOL Button REMOTE CONTROL DISPLAY r r MODE SYMBOLS : COOL : DEHUMIDIFICATION t u : FAN : VENTILATION i t MEGA COOL SYMBOL y FAN SPEED SYMBOLS y o : AUTO Quiet : Manual setting Low High u TEMPERATURE AND TIMER COUNT DOWN INDICATOR i TRANSMITTING SYMBOL...
CV-10NH Operation Manual - Page 16

...Hole "TOP" The exhaust hose should be on the exhaust hose adapter into the window exhaust adapter, and turn it is installed in a sliding sash window. three times) until it is installed in a double-hung sash... Attach the window exhaust adapter to the unit. MODE EXHAUST HOSE COOL, FAN, VENTILATION, DEHUMIDIFICATION with no container Install DEHUMIDIFICATION with the usage mode.
CV-10NH Operation Manual - Page 18

... from the remote control. PRE-OPERATION CHECKS POWER PLUG CHECK This air conditioner uses a fused power plug. The circuit breaker is activated, power is supplied, and the air conditioner is functioning correctly... will appear on the display when batteries are the same type. • If the remote control does not operate normally after replacing the batteries, press the RESET button using a ...
CV-10NH Operation Manual - Page 21

... unit will stop operating and the TIMER, OPERATION and MEGA COOL lamps will rise. Hose band Drain grommet Hose Dehumidi&#...speed is not desirable, install the exhaust hose (See Page 14), turn off . Ensure that the stopcock is securely inserted into a container ... When the stopcock is started. In this mode, the air conditioner dehumidifies the room. Be sure to empty the ...
CV-10NH Operation Manual - Page 22

...select VENT mode. VENTILATION MODE In this mode, the air conditioner simply circulates the air without cooling it. Ensure that the stopcock is securely inserted into...TURN OFF Press the POWER button again. • The red OPERATION lamp on the unit will turn off . FAN MODE In this mode, the air conditioner ventilates the air to outdoors. Install the exhaust hose (See Page14), turn...
CV-10NH Operation Manual - Page 23

..., UP/DOWN air flow direction cannot be set automatically when operated the next time. Do not adjust the vertical louvers to the extreme left or right in the COOL mode with the.... ENGLISH TO CHANGE AIR FLOW DIRECTION UP / DOWN AIR FLOW DIRECTION 1 Press the LOUVERS button on the louvers. Vertical louvers CAUTION Never attempt to malfunction when the remote control is used for...
CV-10NH Operation Manual - Page 24

MEGA COOL OPERATION In this operation, the air conditioner fan works at the formerly set , the unit will automatically turn off. CANCEL NOTES: • The ONE-... button again during cooling mode. • The remote control will display " " . • The temperature display will go off. • The green MEGA COOL lamp on the unit will turn off . • The green MEGA COOL lamp on the ...
CV-10NH Operation Manual - Page 25

...orange TIMER lamp on 6.5 hours later. E-23 maining time. Point the remote control at the signal receiver window on automatically according to the time display.... • When the temperature is set from 10 to 12 hours, in the display for 5 seconds and then ... unit will turn off. TO CANCEL TIMER Press the CANCEL button. • The orange TIMER lamp on the unit will turn on the unit...
CV-10NH Operation Manual - Page 26

...not be set the unit to 12 hours, in 1-hour increments. Up to 9.5 hours, you set from 10 to turn off 2.5 hours later. Display shown when you can not be memorized and will appear on the unit will ...as follows. 0.5h 1.0h 1.5h 10h 11h 12h Hold the button down to your setting. Point the remote control at the signal receiver window on the unit. 1 Press the OFF TIMER button and set together....
CV-10NH Operation Manual - Page 27

E-25 TO TURN OFF NOTES: Press the POWER .... • If the unit has been unplugged since it was last operated, it will turn off. • Upon starting MAIN UNIT operation, the drainage pump inside the unit runs for...produce an audible gurgling sound. ENGLISH MAIN UNIT OPERATION Use this mode when the remote control is not available. 1 Press the POWER button on the unit. • The ...
CV-10NH Operation Manual - Page 28

...OPEN position. Whenever the unit is approximately 41/5 pints. • The OPERATION, TIMER and MEGA COOL lamps will take about one minute. 8 Remove the hose from the drainage nozzle, and ...the TIMER, OPERATION and MEGA COOL lamps are blinking. (This indicates that may be blinking. 7 When drainage water stops running out from the hose, turn the unit off . 2 Turn the drainage nozzle to ...
CV-10NH Operation Manual - Page 29

...unit without the filter. Insect guard net MAINTENANCE AFTER AIR CONDITIONER SEASON 1 Perform drainage to drain out water within the unit....the filters, then reinstall them. CLEANING THE UNIT AND THE REMOTE CONTROL Wipe them . 3 REINSTALL THE FILTERS • Hold the ... onto the unit. Dry the filters in poor cooling performance. Carefully remove any part of the unit. 2 CLEAN ...
CV-10NH Operation Manual - Page 30

...;owing inside the unit. • This air conditioner evaporates water condensed during operation. This is operated on or off, and also during cooling operation within 3 minutes of a power failure? Cooling does not take place in the remote control. The exhaust hose must be retrieved even after the unit is turned on a level floor. Although water...

Similar Questions

Ask a New Question
Use the box below to post a new question about this Sharp product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Sharp Manuals

Find free Sharp CV10NH - 10,000 BTU Portable Air Conditioner manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Sharp Reviews

View thousands of Sharp user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Sharp customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Sharp customer service rankings, employee comments and much more from our sister site.