Get support for Sharp CV10NH - 10,000 BTU Portable Air Conditioner

Sharp CV10NH Support Question

Sharp CV10NH Support Question

Find answers below for this question about Sharp CV10NH - 10,000 BTU Portable Air Conditioner.
Need a Sharp CV10NH manual? We have 1 online manual for this item!
Question posted by Explanet on July 8th, 2014

My Mega Cool Stoped Working . When I Turn It On Only Works In Dehumity.

It stoped working. It has been drained but still doesn't click on. When I try with remote you hear it click twice only on to dehumity. Mega cool won't come on. A/c won't come on but only on dehumitY. Which is low a/c not highers fans. Can you help? Keep in kind it's the 10000 btu.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Sharp CV10NH Manual Pages

CV-10NH Operation Manual - Page 3

...E-10 • INSTALLATION AND REMOVAL OF EXHAUST HOSE .........E-14 • PRE-OPERATION CHECKS E-16 • COOL MODE E-18 • DEHUMIDIFICATION MODE E-19 • FAN MODE E-20 • VENTILATION MODE E-20 • TO CHANGE AIR FLOW DIRECTION E-21 • MEGA COOL ... explains the proper use of your new air conditioner. Please read this manual carefully before using the product.
CV-10NH Operation Manual - Page 5

...and service are not provided free of purchase to Obtain Service: CV-10NH Portable Air Conditioner. Contact your Sharp Authorized Servicer to obtain in-home service for ...the purchaser for parts or labor for the Sealed Cooling System parts; This warranty does not apply to any... is necessary to remove the Product, the Servicer will come to the additional excluded item(s) set forth below nor ...
CV-10NH Operation Manual - Page 6

... any part of this room air conditioner should cause interference to radio or television reception, try to correct the interference by ...turn it is connected. • Consult the dealer or an experienced radio/TV technician for help. Pulling or misuse of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the room air conditioner...
CV-10NH Operation Manual - Page 7

...turn... weather may cause water to a grounding plug. Cooling performance may freeze inside the hose, causing water inside ...Drained water may be plugged into the room. • The temperature around the drainage hose must have no kinks or be below freezing point when used , make sure the electrical box is properly grounded. This appliance must be performed whenever moving the air conditioner...
CV-10NH Operation Manual - Page 8

... rise. Accordingly, the same amount of air, making your air conditioner work harder and less efficiently. In this case, perform drainage to drain out water within three minutes, a protective device in cool mode. ENERGY EFFICIENCY TIPS • Avoid direct sunlight. Your air conditioner must be blown out from the Exhaust air outlet, but this is normal and...
CV-10NH Operation Manual - Page 10

... control signal receiver 4 window 5 5 POWER Button 6 6 OPERATION Lamp (red) 7 7 TIMER Lamp (orange) 8 9 8 MEGA COOL Lamp (green) 9 9 Air inlet 9 REAR VIEW 0 0 Exhaust air outlet q q Window exhaust adapter w w Exhaust hose e e Remote control hook r t r Air filters y t Drainage nozzle and stopcock y Power supply cord hooks u Drainpipe nozzle and stopcock u i Power...
CV-10NH Operation Manual - Page 11

... OFF Button 6 MODE Button 7 ON TIMER Button 8 FAN Button 9 OFF TIMER Button 0 CANCEL Button q LOUVERS Button w RESET Button e MEGA COOL Button REMOTE CONTROL DISPLAY r r MODE SYMBOLS : COOL : DEHUMIDIFICATION t u : FAN : VENTILATION i t MEGA COOL SYMBOL y FAN SPEED SYMBOLS y o : AUTO Quiet : Manual setting Low High u TEMPERATURE AND TIMER COUNT DOWN INDICATOR i TRANSMITTING SYMBOL...
CV-10NH Operation Manual - Page 14

INSTALL WINDOW PANEL Installation in a sliding sash window (See page 10 for installation in the window. Push the insect guard net firmly to the window frame. 4 Install the window panel into the holes in the ...
CV-10NH Operation Manual - Page 16

... in a double-hung sash window. three times) until it (approx. Insert the two projections on the exhaust hose adapter into the window exhaust adapter, and turn it stops. MODE EXHAUST HOSE COOL, FAN, VENTILATION, DEHUMIDIFICATION with no container Install DEHUMIDIFICATION with the usage mode.
CV-10NH Operation Manual - Page 20

... set within the range of 64°F to 86°F. 1 4 4 Press the FAN button to select COOL mode. COOL MODE Drainage nozzle "CLOSE" position Stopcock Install the exhaust hose (See Page14), turn off. AUTO QUIET LOW HIGH TO TURN OFF Press the POWER button again. • The red OPERATION lamp on the unit will...
CV-10NH Operation Manual - Page 21

...14), turn off . Hose band Drain grommet Hose... Always perform this mode, the air conditioner dehumidifies the room. ...MEGA COOL lamps will blink. COOL DEHUM FAN VENT 2 2 Press the power button to start operation. • The red OPERATION lamp on the unit will light. • The temperature cannot be set. • The fan speed is preset to AUTO and cannot be changed. 1 TO TURN...
CV-10NH Operation Manual - Page 22

... red OPERATION lamp on the unit will turn off . FAN MODE In this mode, the air conditioner ventilates the air to outdoors. Install the exhaust hose (See Page14), turn the drainage nozzle to set the desired fan speed. VENTILATION MODE In this mode, the air conditioner simply circulates the air without cooling it. COOL DEHUM FAN VENT 2 2 Press the POWER button...
CV-10NH Operation Manual - Page 23

...8226; During VENTILATION mode, UP/DOWN air flow direction cannot be set to "QUIET ( )" for an extended period of time, condensation may form on the remote control. • The horizontal louvers will...adjustment. • When the horizontal louvers are at the lowest position in the COOL or DEHUMIDIFI- Condensation may result. Vertical louvers CAUTION Never attempt to adjust the ...
CV-10NH Operation Manual - Page 24

...operating, the unit will turn off after one hour. MEGA COOL OPERATION In this operation, the air conditioner fan works at the formerly set the temperature or fan speed during MEGA COOL operation. • The...OFF TIMER button again during cooling mode. • The remote control will display " " . • The temperature display will go off. • The green MEGA COOL lamp on the unit ...
CV-10NH Operation Manual - Page 25

... the button down to 12 hours, in the display for 5 seconds and then return to turn off. TO CANCEL TIMER Press the CANCEL button. • The orange TIMER lamp on ... minimum of half an hour (30 minutes) to a maximum of 12 hours. Point the remote control at the signal receiver window on the unit. 1 Press the ON TIMER button. •... duration can set from 10 to show in 1-hour increments.
CV-10NH Operation Manual - Page 26

... memorized and will appear on the unit will turn off 2.5 hours later. TO CANCEL TIMER Press the CANCEL button. • The orange TIMER lamp on the remote control display the next time you press the ...will be cancelled and will not be set in 1-hour increments. E-24 Timer duration can set from 10 to your setting. maining time. Up to 9.5 hours, you set while the OFF TIMER or ...
CV-10NH Operation Manual - Page 27

TO TURN OFF NOTES: Press the POWER button ...settings. • If the unit has been unplugged since it was last operated, it will turn off. • Upon starting MAIN UNIT operation, the drainage pump inside the unit runs for...speed set at 68˚F. E-25 ENGLISH MAIN UNIT OPERATION Use this mode when the remote control is not available. 1 Press the POWER button on the unit. • The red...
CV-10NH Operation Manual - Page 28

... within the unit in the following cases. Stopcock 7 Replace the stopcock to turn the unit off by pressing POWER button. Drainpipe nozzle E-26 Maximum amount of water that may be drained out is approximately 41/5 pints. • The OPERATION, TIMER and MEGA COOL lamps will take about one minute. 4 Remove the hose from the...
CV-10NH Operation Manual - Page 29

... (120°F/50°C or hotter) when cleaning. CLEANING THE INSECT GUARD NET The cooling performance may result in the FAN or VENTILATION mode for about half a day to the ... guard net MAINTENANCE AFTER AIR CONDITIONER SEASON 1 Perform drainage to drain out water within the unit. (See Page 26 "When the unit is clogged with a mild soap. CLEANING THE UNIT AND THE REMOTE CONTROL Wipe them . ...
CV-10NH Operation Manual - Page 30

...through the exhaust air outlet. It must not be heard for about 5 minutes. • Are the OPERATION, TIMER and MEGA COOL lamps blinking? ...drained. (See page26) • Check the power plug. (See page16) AIR CONDITIONER DOES NOT COOL PROPERLY • Is it set to be heard when the unit is turned on or off , preventing cooling for the first 2 to send the signal again with the remote...

Similar Questions

Ask a New Question
Use the box below to post a new question about this Sharp product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Sharp Manuals

Find free Sharp CV10NH - 10,000 BTU Portable Air Conditioner manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Sharp Reviews

View thousands of Sharp user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Sharp customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings