Get support for Sharp CV10NH - 10,000 BTU Portable Air Conditioner

Sharp CV10NH Support Question

Sharp CV10NH Support Question

Find answers below for this question about Sharp CV10NH - 10,000 BTU Portable Air Conditioner.
Need a Sharp CV10NH manual? We have 1 online manual for this item!
Question posted by issacsaumel on July 4th, 2014

How To Drain Sharp Portable Room Air Conditioner

The person who posted this question about this Sharp product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Sharp CV10NH Manual Pages

CV-10NH Operation Manual - Page 3

...8226; INSTALL WINDOW PANEL E-10 • INSTALLATION AND ...AIR FLOW DIRECTION E-21 • MEGA COOL OPERATION E-22 • ONE-HOUR OFF TIMER E-22 • TIMER OPERATION E-23 • MAIN UNIT OPERATION E-25 • DRAINAGE E-26 • MAINTENANCE E-27 • BEFORE CALLING FOR SERVICE E-28 E-1 ENGLISH ENGLISH This manual explains the proper use of your new air conditioner...
CV-10NH Operation Manual - Page 4

... TO WRITE: For service problems, warranty information, missing items and other assistance: Sharp Electronics Corporation Customer Assistance Center 1300 Naperville Drive Romeoville, IL 60446-1091 TO ACCESS...number, date of purchase, your complete mailing address (including zip code), your nearest Sharp Authorized Servicer) PARTS (for reporting loss or theft, please record below the model and serial...
CV-10NH Operation Manual - Page 5

...period. From a Sharp Authorized Servicer located in design or construction. Be sure to improper voltage or other than those described herein, or to Obtain Service: CV-10NH Portable Air Conditioner. The warranties described... SPECIFlC LEGAL RIGHTS. Contact your home, and if it will come to your Sharp Authorized Servicer to have Proof of the Product, filters, or accessories, or any...
CV-10NH Operation Manual - Page 6

... of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the room air conditioner and radio/TV receiver. • Connect the room air conditioner into any part of any part of this room air conditioner should cause interference to radio or television reception, try to correct the interference by manufacture's service agent in...
CV-10NH Operation Manual - Page 7

... drained water may be below freezing point when used , make sure the electrical box is equipped with obstacles. Cooling performance may spill out into the room. • Do not block the exhaust air ...can cause electrical shock or equipment damage. • Drainage should be performed whenever moving the air conditioner. (See Page 26) If any water remains in the tank, it may freeze inside the...
CV-10NH Operation Manual - Page 8

... unit is home. Accordingly, the same amount of a power failure during dehumidification mode and the room temperature will return to drain out water within the unit. (See page 26) OPERATING CONDITIONS • The air conditioner must remove the heat produced by the unit outside through any lights or appliances that are not...
CV-10NH Operation Manual - Page 9

...placed within reach of a properly rated grounded socket. • Never place any obstacles around the air inlet or outlet of the unit. • Allow at surfaces. Do not attempt to aid ... SUGGESTED TOOLS FOR WINDOW PANEL INSTALLATION 1. Tape measure or ruler 3. ENGLISH LOCATION • The air conditioner should only be rolled on smooth, flat least 12" (30cm) of space from the...
CV-10NH Operation Manual - Page 10

... signal receiver 4 window 5 5 POWER Button 6 6 OPERATION Lamp (red) 7 7 TIMER Lamp (orange) 8 9 8 MEGA COOL Lamp (green) 9 9 Air inlet 9 REAR VIEW 0 0 Exhaust air outlet q q Window exhaust adapter w w Exhaust hose e e Remote control hook r t r Air filters y t Drainage nozzle and stopcock y Power supply cord hooks u Drainpipe nozzle and stopcock u i Power supply...
CV-10NH Operation Manual - Page 18

...correctly aligned. • Lines will not be performed. PRE-OPERATION CHECKS POWER PLUG CHECK This air conditioner uses a fused power plug. E-16 RESET TEST TEST RESET Do not attempt to use . ... Press the TEST button. The circuit breaker is activated, power is supplied, and the air conditioner is functioning correctly. 4 Press the RESET button until you will appear on the display ...
CV-10NH Operation Manual - Page 19

... to block out the sunlight. • Use of a fluorescent lamp in the same room may interfere with transmission of the signal. • The unit may adversely affect its operation. ...remote control from moisture and shock which can discolor or damage it to the unit when not in the same room. • Do not leave the remote control exposed to 23 feet (7 meters) away. CAUTION •...
CV-10NH Operation Manual - Page 21

...position 4 Attach the drain grommet to a ...room temperature to slightly drop the room temperature, but dehumidification performance will become full, the unit will stop operating and the TIMER, OPERATION and MEGA COOL lamps will spout out if attempted during dehumidification mode and the room temperature will rise. In this mode, the air conditioner dehumidifies the room...
CV-10NH Operation Manual - Page 22

...set the desired fan speed. • Although the louvers are closed and no air blows 3 out into the room, the external ventilation fan speed changes. Ensure that the stopcock is securely inserted ...Press the FAN button to set the desired fan speed. FAN MODE In this mode, the air conditioner ventilates the air to outdoors. QUIET LOW HIGH 3 TO TURN OFF Press the POWER button again. •...
CV-10NH Operation Manual - Page 23

...lowest position in the COOL or DEHUMIDIFI- Condensation may result. E-21 Horizontal louvers LEFT / RIGHT AIR FLOW DIRECTION Hold the vertical louver as shown in the COOL mode with the fan speed set... automatically when operated the next time. NOTE • During VENTILATION mode, UP/DOWN air flow direction cannot be set to "QUIET ( )" for an extended period of time, ...
CV-10NH Operation Manual - Page 24

... fan speed during MEGA COOL operation. • The fan returns to the HIGH speed setting after one hour. MEGA COOL OPERATION In this operation, the air conditioner fan works at the formerly set condition. • If you wish to operate the unit for another hour before the ONE-HOUR OFF TIMER is...
CV-10NH Operation Manual - Page 25

... of 12 hours. Select the mode, temperature and fan speed setting as follows. 0.5h 1.0h 1.5h 10h 11h 12h 1 Display shown when you set from 10 to your setting. E-23 Timer duration can set with the ON TIMER, the temperature will operate using the most recent setting. Point the remote control...
CV-10NH Operation Manual - Page 26

TIMER OPERATION OFF TIMER The unit will turn off . Display shown when you set from 10 to 12 hours, in half-hour (30-minutes) increments and from a minimum of half an hour (30 minutes) to a maximum of 12 hours. Timer duration ...
CV-10NH Operation Manual - Page 28

...nozzle to the drainage nozzle, and secure it with the hose band. • Prepare for draining, as drain water will come out through the drainage hose. When the unit is approximately 41/5 pints. &#...8226; The OPERATION, TIMER and MEGA COOL lamps will be drained out is approximately 2/5 pints. Maximum amount of water that the water tank inside the unit is...
CV-10NH Operation Manual - Page 29

... completely if the insect guard net becomes clogged with dust. Insect guard net MAINTENANCE AFTER AIR CONDITIONER SEASON 1 Perform drainage to drain out water within the unit. (See Page 26 "When the unit is clogged with dust, the airflow will be cleaned every two weeks. To avoid damaging the unit, do not...
CV-10NH Operation Manual - Page 30

... This air conditioner evaporates ... the air conditioner, ... air conditioner in...drained. (See page26) • Check the power plug. (See page16) AIR CONDITIONER... DOES NOT COOL PROPERLY • Is it set properly? • Is the window exposed to shut off for less than 3 minutes when, you restart the unit within the unit through the exhaust air outlet. No air...oor. AIR CONDITIONER DOES...
CV-10NH Operation Manual - Page 60

TH 1 ESPAÑOL SHARP ELECTRONICS CORPORATION Sharp Plaza, Mahwah, New Jersey 07430-2135 U.S.A SHARP CORPORATION S-31 Printed in Thailand TINSEA541JBRZ 07M-

Similar Questions

Ask a New Question
Use the box below to post a new question about this Sharp product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Sharp Manuals

Find free Sharp CV10NH - 10,000 BTU Portable Air Conditioner manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Sharp Reviews

View thousands of Sharp user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Sharp customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Sharp customer service rankings, employee comments and much more from our sister site.