No Ignition Of Gas

When I turn on the heater, I hear a click, but there's no ignition of the gas; therefore no flame.  I have checked the outlet flow and there's plenty of flow.  The gas is turned on.  In the past year,  I experienced the flame coming on, it would then go off on its own, turn off for 30 secs and then reignite on it's own and stay on

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Rheem P-M337 Manual Pages

Brochure - Page 2

...can connect to monitor and measure the pilot flame signal. Known for years of a remote system. POOL & SPA HEATERS Model 206 266 336 406 BTUH Input 199...gas valve ensures smooth turn-on with its exclusive low-profile design. Rheem Digital gas heateR Microprocessor-Controlled Thermostat Sp a S e t 104F Heating The Rheem Digital gas heater is equipped with a robust flame...
Operating Instructions - Page 1

This manual should be performed by a qualified installer, service agency or the gas supplier. INSTALLATION & OPERATING INSTRUCTIONS Gas-Fired Pool & Spa Heater Atmospheric Models 206A, 266A, 336A & 406A Lo NOx Models 207A, 267A, 337A & 407A WARNING: If these instructions are not followed exactly, a fire or explosion may ...
Operating Instructions - Page 2

... MAXIMUM** 3000 MAXIMUM** 3000 MAXIMUM** * Free Chlorine MUST NOT EXCEED 5 PPM! ** In salt water chlorinated pools, the total TDS can damage your water. Additions: Control Lockout instructions on pages 48-55. A check valve should be installed between the heater outlet and a chlorinator or other chemical dosing device. • Further advice should not damage the...
Operating Instructions - Page 3

... 8 Automatic Chlorinators & Chemical Feeders 38 Water Pressure Switch 9 Cold Weather Operation 38 Flame Roll-Out Safety Switch 9 Winterizing the Pool & Spa Heater 38 High Limits 10 PART TWO 39 Pilot Safety INSTALLATION & SERVICE INSTRUCTIONS 39 Burner Tray Removal (ATM) 10 SECTION 1 39 Gas Valve Removal (ATM) RECEIVING EQUIPMENT 39 Main Burner and Orifice Removal (ATM...
Operating Instructions - Page 4

...pool/spa heater has been designed for these heaters. This manual provides installation, operation, maintenance, and service information for years of toggle switch to turn the heater On and Off. See figure above for location of safe and reliable pool/spa water heating. Do not obstruct the flow... is filled with millivolt or electronic ignition. Keep heater area clear and free from 65&#...
Operating Instructions - Page 7

... check the water temperature with a well-defined pattern. 4" MAX WARNING: Operation of alcoholic beverages before using pools or hot tubs. 6. The flame should be blue with an accurate thermometer; Otherwise, rapid and severe damage will likely occur to shut off, turn off and contact your installer or gas supplier. Soaking in drowning. 3. Before entering the spa...
Operating Instructions - Page 8

... is shut off and contact your heater and associated equipment. Yellow flame means restriction of dust and lint. 3. CAUTION: Combustion air must be installed between the heater outlet and the chlorinator. 6. Your filter may be combustible. If there is dirty, look to prevent chemical back-up and then semiannually. 1. POOL & SPA WATER CHEMISTRY Chemical imbalance can...
Operating Instructions - Page 9

... be maintained. COLD WEATHER OPERATION WINTERIZING THE POOL & SPA HEATER IMPORTANT FREEZE INFORMATION MODERATE CLIMATE: Heater operation can seriously damage the heater, and is a must. When starting the heater with pool water below 50°F, operate the heater continuously until higher temperatures are between 0° and 32°F, flow (continuous pump operation) must be taken...
Operating Instructions - Page 10

... you visually check for the equipment. These items are any questions that this manual does not answer, please contact the factory or your pool/spa heater. Bonding lug with the heater: STANDARD UNIT... display Model & Serial No. On receipt of installation. Plastic pipe finish flange for gas line. 9. Bonding lug with "O" rings (2) 2. When ordering under warranty conditions, ...
Operating Instructions - Page 11

...Heater Components Millivolt Heater with Honeywell Gas Valve +32°F to +175°F Millivolt Heater with adequate drainage, be avoided, it is recommended that a suitable drain pan, with Robertshaw Gas Valve 0°F to +175°F Electronic Ignition Heater...personnel, specifically trained and experienced in the absence of local...must not restrict combustion air flow. When cleaning spills, ...
Operating Instructions - Page 20

... VALVE UNION Gas Pressure Adjustment Robertshaw 7000 DERHC (Heater Model 406) Non-Adjustable Gas Valve MANOMETER GAS PRESSURE TEST AT GAS VALVE GAS PRESSURE ADJUSTMENT LOCATIONS MILLIVOLT GAS VALVES Robertshaw 7000 BDERF (Heater Models 207-407) PIPE SIZING FOR GAS CONNECTIONS Gas Pressure Adjustment Robertshaw 7000 (Heater Models 206-406) ELECTRONIC IGNITION GAS VALVES Gas Pressure Adjustment...
Operating Instructions - Page 23

... Heater CAST IRON HEADER PRV (ASME MODELS) To Pool/ Spa From Pool/ Spa AUXILIARY BYPASS VALVE (DO NOT USE GATE VALVE) AUXILIARY BYPASS VALVE ADJUSTMENT To set bypass: With clean filter, adjustment is provided in the header for this flow rate. Usually a high-performance pump size larger than inlet and comfortable to the spa jets, etc. This...
Operating Instructions - Page 25

... water flow through the heater and check for ...heater. 5. Apply a non-petroleum-based lubricant to the tube sheets. Do not over tighten. Remove (12) bolts holding the inlet/outlet and return headers to the gasket such as AquaLube. Reconnect high limit, AGS, and pressure switch wires. 7. Tighten 1/2 turn past...AGS (automatic gas shut-off), and pressure switch on the in an...
Operating Instructions - Page 35

... not in Pool, Spa and Remote modes. Pilot flame lost during the 8 second trial to ignite the main burner. Display Heating Condition Call for heat present. Fault manded state. Time clock/fireman switch circuit is satisfied The following conditions are commanded shut. Hi Limit 2 Fault High limit 2 open . Flow/Field SW #2 Field-supplied flow switch/field...
Operating Instructions - Page 38

... 20 minutes prior to shutting down the pool pump. Make sure the pool filter is equipped with two automatic high limits. Manually turn counter-clockwise. 8. MAX POOL OR SPA 5 FT. This is a wire nut located in the heater's wiring. On millivolt heaters the fireman's switch connection is a "single-use a multimeter to check). It is located on the low...
Operating Instructions - Page 41

... NOx POOL HEATERS The Lo NOx pool heaters are equipped with a combustion air plate (baffle) mounted on power to the outlet pipe connection. 4. OPERATION On call for proper operation. Spark will turn on gas supply....prevent flame roll-out in the event the heat exchanger becomes blocked. Shut water, gas and electricity off device to the blower. Snap in place for heat, the ignition system...
Operating Instructions - Page 45

...pilot gas valve, flow switch etc. Take protective action to shield cable and boot from excessive temperatures. • Check that pilot flame covers flame rod and is not blocked. • Check electrical connections between PC board and gas control. Make sure that shuts off pilot gas if pilot fails to heater. Pull ignition lead and check spark at module; ELECTRONIC IGNITION IID...
Operating Instructions - Page 46

... displayed? NO YES Push MODE switch to select "Pool" or "Spa" Push Temp arrow to scroll to the heater. High limit switch. Press manual reset button. CONTROL LOGIC - Sensor resistance at tube fitting). Inspect internal Thermostat (Unitherm Governor) and bypass valve. Check for instructions. Ignition failure. FLOW CHART Power On Is the water temperature displayed...
Technical Data - Page 2

... multiple unit installations, the load can shorten heater life. • High Flow Rates The Rheem gas heater comes with an automatic bypass built into the pool control system of your choice. • Electronic Ignition Rheem Digital heaters come standard with the heater, the digital display will find that the heater is capable of handling water flow at all times. Quality assurance •...
Warranty - Page 1

... nature, accident, fire, flood, freeze, lightning or the like; 7. APPLICABLE WARRANTY PERIOD If the HEATER is one (1) year from defects in the contiguous 48 states with the cabinet door off, having flow restrictions or obstructions between the heater outlet and the pool/spa, or not maintaining a proper chemical balance (PH level must be between 7.4 and 7.8 and total...

Similar Questions

Pilot Light Issues
when trying to light the pilot light it goes put as soon as I release the pilot button. It does ligh...
(Posted by mdowell23 2 years ago)
Clk Code Wont Ignite Pm337a Rheem Pool Heater
the CHS comes on but no dark then CLK code comes on
(Posted by lillylill 2 years ago)
P-m266a-en-x Pool Heater Water Switch Open Error Message.
how do I adjust/replace or reset the water pressure switch on the pool heater. The manual included w...
(Posted by pricerd 2 years ago)
Ask a New Question
Use the box below to post a new question about this Rheem product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Rheem Manuals

Find free Rheem P-M337 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Rheem Reviews

View thousands of Rheem user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Rheem customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Rheem customer service rankings, employee comments and much more from our sister site.

Rheem Recalls

Find comprehensive Rheem recall information updated hourly on RecallOwl.com.