Get support for Maytag MED5800TW - Electric Dryer

Maytag MED5800TW Support Question

Maytag MED5800TW Support Question

Find answers below for this question about Maytag MED5800TW - Electric Dryer.
Need a Maytag MED5800TW manual? We have 2 online manuals for this item!
Question posted by izzi811 on January 12th, 2012

Dryer Won't Start

my maytag dryer wont start already checked thermal fuse what else can i check i can hear the timer running and the start switch checks out good

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Maytag MED5800TW Manual Pages

Technical Education - Page 3

... Moisture Sensor And Metal Oxide Varistors (MOVS 4-18 Removing The Drum Light Assembly 4-20 COMPONENT TESTING 5-1 Door Switch 5-1 Thermal Fuse & Exhaust Thermistor 5-2 High-Limit Thermostat & Thermal Cutoff (TCO) (Gas Models Only 5-2 Flame Sensor 5-3 Gas Burner Coils 5-3 Burner Ignitor 5-4 Electric Heater (Dual Element 5-4 Thermal Cutoff (TCO) And Inlet Thermistor/High-Limit Thermostat...
Technical Education - Page 9

...exhaust system hardware. 2-1 Read "Electrical Requirements," "Gas Supply Requirements" and "Venting Requirements" before starting installation. Mobile home installations require ...Check local codes and with any tools listed here. Check existing gas supply, electrical supply and venting. For further information, please refer to 1˝ (2.54 cm) or hex-head socket wrench (for adjusting dryer...
Technical Education - Page 32

... to follow these instructions can result in a running or "On" position. • Start button has been pushed firmly. • Dryer is plugged into a grounded outlet and/or electrical supply is on power. dryer door and feel for the dryer. If you do not feel heat, turn off the dryer and check the following : er door and feel for...
Technical Education - Page 36

Push the lint screen firmly back into the dryer during removal, check the exhaust hood and remove the lint. Place dryer at least 18 inches (46 cm) above the floor for a garage installation. IMPORTANT: • Do not run the dryer with hot water. The lint screen is located on top of the drum and rub...
Technical Education - Page 38

... non-use 2 household fuses or circuit breakers. The dryer will not start in "Dryer Use." 3-6 Check the front and rear edges of the dryer? See the Installation Instructions. • Is the clothing knotted or balled up , the load will not run Unusual sounds • Has a household fuse blown, or has a circuit breaker tripped? The timer moves only when the...
Technical Education - Page 41

... Timer Temperature Switch Push To Start Switch Signal Switch AC Heater Relay Drum Roller (2) Heater Assembly Door Switch High Limit Thermostat Thermal Cutoff Drum Light Assembly Moisture Sensor (Behind Strips) Thermal Fuse Exhaust Thermistor Drive Motor 4-1 COMPONENT ACCESS This section instructs you on how to service each component inside the Maytag Centennial™ Electric & Gas Dryers...
Technical Education - Page 42

... On Control Panel Rear Console Cover Screw (6) Timer AC Heater Relay Wrinkle Prevent Switch Temperature Switch Elect. Replace all parts and panels before servicing. Failure to unlatch the two catches and tabs. Control Board Push To Start DC Motor Relay Switch End Of Cycle Signal Switch DC Heater Relay 5. Unplug dryer or disconnect power. 2. Slide the blade...
Technical Education - Page 43

...screw, and remove the relay from the control panel. To remove the push to start switch: a) Pull the knob off the switch. AC Heater Relay (2) BR (2) BK (2) BK Tab Continued on the next...(DC Htr.) (2) BU (DC Mtr.) (2) RD (DC Htr.) d) Unsnap the push to start switch from the relay terminals. b) Disconnect the wire connectors from the relay terminals. To remove the AC heater relay...
Technical Education - Page 52

... component. Replace all parts and panels before servicing. Failure to dryer. 3. Thermal Fuse BK RD-WH Exhaust Thermistor 2 RD-WH Viewed From Rear Of Dryer 4-12 Turn off gas supply to do so can result in death or electrical shock. 1. Remove the two wires from the thermal fuse or exhaust thermistor terminals. 5. Remove the rear panel (see...
Technical Education - Page 62

... should indicate as shown in death or electrical shock. Set the ohmmeter to the thermal fuse terminals. Unplug dryer or disconnect power. 2. Unplug dryer or disconnect power. 2. TEMP. The meter should indicate a closed circuit (0 Ω) for both components. 5-2 NOTE: The thermal fuse opens at 196°F (91°C). 6. THERMAL FUSE & EXHAUST THERMISTOR HIGH-LIMIT THERMOSTAT...
Technical Education - Page 66

...dryer. 3. Unplug dryer or disconnect power. 2. Turn off gas supply to page 4-10 for the procedure for accessing the drive motor. 1. Measure the drive motor main and start windings, as shown in death or electrical shock. Failure to the R x 1 scale. 5. WARNING Electrical...motor switch START 1.4 - 2.8 Blue wire in back at pin 4 and bare copper wire on pin 3 of black drive motor switch 5-6...
Technical Education - Page 69

...timer. • If there is securely fastened to Start (PTS) Switch Temperature Switch Timer Wrinkle Prevent Switch Signal Switch A.C. In a similar way, check which terminal of the terminal block, replace the power cord and test the dryer...an ohmmeter, check for electric dryer. • If there is no continuity and the mechanical connections of the dryer. 3. Unplug dryer or disconnect ...
Technical Education - Page 70

... black wire of the dryer and check that the timer motor advances (should be measured. • If it does not, perform the Thermal Fuse Test and Door Switch Test and check harness continuity. If an open circuit is found , replace the power cord. If an open ) should run continuously). Check the timer motor resistance and timer switching. Use the timer encoding table below...
Technical Education - Page 72

...limit thermostat. • If closed, apply heat. Check the thermal cut-off for failed thermistor or other causes of thermal fuse. 3. Thermal Fuse Test-Electric A thermal fuse is shut off to the motor. (Centrifugal switch in gas valve also opens heater circuit.) 1. Check continuity of failure. See Thermal Components illustration. The thermal fuse is wired in series with a "one-shot...
Technical Education - Page 73

...replace the thermistor. • If the thermistor resistance checks agree with heater off and on and off to ...Timer dial - must be 30°F (17°C) higher. • If the exhaust temperature is not within specified limits: - Remove exhaust vent and start the dryer. • Turn Temperature switch to desired temperature to Start switch. • If you hear three short beeps and the dryer...
Technical Education - Page 75

...page 7-3 or 7-6. - WRINKLE PREVENT DOES NOT RUN. ELECTRONIC CONTROL - PUSH TO START (PTS) SWITCH RUN. - ELECTRONIC CONTROL For more details, see Troubleshooting section, page 6-10. THERMAL FUSE HEAT. - DRYER SHUTS OFF BEFORE CLOTHES ARE DRY. and Moisture Sensor Strip Circuit, page 7-3 or 7-6. - HARNESS/CONNECTION - MOISTURE SENSOR - Refer to Timer Drawing, page 7-2 or 7-5;
Technical Education - Page 76

and Troubleshooting Guide, page 6-9. 1. Perform Thermal Fuse Test, page 6-6. 5. If motor did not continue to run position. Perform Supply Connections Test, page 6-3. 2. Unplug dryer or disconnect power. 5. This can be open to 2M. PROBLEM: Dryer Will Not Heat Gas Only Refer to Start (PTS) switch continuity when pressed. Perform Door Switch Test, page 6-5. 6. and ...
Technical Education - Page 79

...TIMER ELECTRONIC CONTROL BK PT-1 TIMER P2-6 DOOR R TCO 310°F (154°C) R-W BU V R W BU BU COM HEATER RELAY P1-1 MTR P1-2 T2 P1-3 T3 P1-4 T4 MOIST GND MOIST. NEUTRAL W-R R - LINE L2 BU BU DOOR SWITCH NEUTRAL W TERMINAL LINKED TO CABINET W W R W BU BU THERMAL FUSE 196 °F (91°C) MAIN 2.4-3.6 START...-5 48 VDC MOTOR LOUD START SOFT START SENSE MODEL MODEL 120 VAC...
Technical Education - Page 81

... TERMINAL LINKED TO W CABINET W BU BU THERMAL FUSE 196 °F (91°C) MAIN 2.4-3.6 5M 2M CENTRIFUGAL SWITCH START 2.4-3.8 3M 6M 1M DRIVE MOTOR 1/3 H.P. P2-3...TIMER ELECTRONIC CONTROL BK BK PT-1 TIMER BU P1-1 MTR MOIST P2-5 GND MOIST. HEATER L1 LINE - BK THERMAL CUT-OFF (TCO) 310 °F (154°C) ELECTRONIC CONTROL TEMP. BK TIMER ELECTRONIC CONTROL BK BK PT-1 TIMER...
Technical Education - Page 82

... BK DL OR W Gas Dryers WIRING DIAGRAM 7-4 TIMER BK BU ELECTRONIC CONTROL BK PT-1 TIMER DOOR P2-6 BU P1-1 MTR V P1-2 T2 R P1-3 T3 W P1-4 T4 MOIST. START 2.4-3.8 5M CENTRIFUGAL SWITCH 3M 6M BK IG IGR IGNITOR 2 HS1 NC BU BK R-W HIGH LIMIT THERMOSTAT 205°F (96°C) HS2 THERMAL CUT-OFF NONRESETTABLE THERMAL FUSE 196°F (91...

Maytag Knowledge Base Results

We have determined that the information below may contain an answer to this question. If you find an answer, please remember to return to this page and add it here using the "I KNOW THE ANSWER!" button above. It's that easy to earn points!

  • Fabric is too hot - Dryer
    ... very warm. My dryer will not start Loads are wrinkled - Was a high temperature cycle used, or was a separate temperature control set on high? Dryer Loads are damp; Dryer Allow the load to run through the Cool Down part of the cycle before removing the laundry items from  the dryer. Fabric is increasing - Dryer Fabrics are too hot...
  • Cycle is too short - Dryer
    ...strips if the dryer is not level. Make sure that the dryer is heating, check the following for  an Automatic Dry or Sensor Dry cycle. Electric dryer Dryer does not heat - Dryers with .... Moving the knob toward Very Dry will not start Gas dryer If the dryer is heating, view the following : Is the dryer level? Use Timed Dry for the automatic drying...
  • Display shows L2 - Dryer
    ... problem continues, call an electrician. Does the dryer have heat. Is the dryer drum not turning, or is  an L2 code on the display. Electric dryers use two household fuses or circuit breakers. Dryer does not heat - Replace the fuse(s) or reset the circuit breaker(s). If the dryer has heat, disregard the L2 code on...

Similar Questions

Maytag Med5800two
Dryer will not shut off on it's own. Tried using the timing side of the dial and the "auto sense" s...
(Posted by georgektexas 13 years ago)
Why Won't The Dryer Start?
I replaced the power cord, the receptacle, and the wiring to the breaker panel. I think the on/off/s...
(Posted by schmall5 14 years ago)
Ask a New Question
Use the box below to post a new question about this Maytag product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Maytag Manuals

Find free Maytag MED5800TW - Electric Dryer manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Maytag Reviews

View thousands of Maytag user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Maytag customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Maytag customer service rankings, employee comments and much more from our sister site.

Maytag Recalls

Find comprehensive Maytag recall information updated hourly on RecallOwl.com.