LiftMaster MATDCBB3 Support Question
Find answers below for this question about LiftMaster MATDCBB3.Need a LiftMaster MATDCBB3 manual? We have 1 online manual for this item!
Question posted by Danl97549 on April 2nd, 2017
Blown Fuse
we keep blowing a fuse in the unit. Power source has been confirmed to be good with no shorts. Grounding has been checked and approved. Neutral connection on the 120v side is connected correctly. Panelboard it is being fed from is properly grounded and bonded as it is the first point of disconnect from the transformer it is being fed from. The gate arm is not binding and the belt tension is not too tight.
Current Answers
Answer #1: Posted by waelsaidani1 on April 2nd, 2017 4:43 PM
If the gate is out of adjustment and slams the stops to hard, it could blow fuses. Replace the fuse and adjust the limits on the open or close side so the operator stops running just prior to hitting the stops. The stops are only intended to position the gate firmly open or shut. They are not meant to literally stop the gate.
Related LiftMaster MATDCBB3 Manual Pages
Similar Questions
Garage Door Opens After Shutting.
My Lift master 8550 inside keypad is Inside wall pad is model #880LM. outside keypad Model # is 877M...
My Lift master 8550 inside keypad is Inside wall pad is model #880LM. outside keypad Model # is 877M...
(Posted by BONNIECA92 2 years ago)
Matdcbb3 Gate Operator
gate arm comes down and immediately goes back up instead of staying down
gate arm comes down and immediately goes back up instead of staying down
(Posted by thomaszachmann 2 years ago)
I Cannot Get My Gate Arm To Close. The Close 6 Light Is On
(Posted by MSAdimando 4 years ago)
Remote Won't Sync With Gate
I have used the receiver on the gate entry unit to connect with my remote. The receiver indicated li...
I have used the receiver on the gate entry unit to connect with my remote. The receiver indicated li...
(Posted by kellineal 9 years ago)
Garage Door Opener Will Not Close It Says Power Restored
(Posted by LETcynd 10 years ago)