Question posted by themink33 on August 24th, 2016

Liftmaster La500 Wont Open Or Close More Than Halfway

I keep getting codes 32 91 and 93

Current Answers

Answer #1: Posted by mashallah on August 25th, 2016 3:54 AM
This answer was accepted by the poster of the original question.
mashallah

Member since:
August 25th, 2016

Points: 2,390
1,100
points
  • If the door does not open completely but opens at least five feet (1.5 m):
    • Increase up travel. Turn the UP limit adjustment screw clockwise. One turn equals 2" (5 cm) of travel.
    • NOTE: To prevent the trolley from hitting the cover protection bolt, keep a minimum distance of 2-4" (5 cm - 10 cm) between the trolley and the bolt.
  • If door does not open at least 5 feet (1.5 m):
    • Adjust the UP (open) force as explained in Adjustment Step 2.
  • If the door does not close completely:
    • Increase down travel. Turn the DOWN limit adjustment screw counterclockwise. One turn equals 2" (5 cm) of travel.
    • If door still won't close completely and the trolley bumps into the pulley bracket, try lengthening the door arm (page 18) and decreasing the down limit.
  • If the opener reverses in fully closed position:
    • Decrease down travel. Turn the DOWN limit adjustment screw clockwise. One turn equals 2" (5 cm) of travel.
  • If the door reverses when closing and there is no visible interference to travel cycle:
    • If the opener lights are flashing, the Safety Reversing Sensors are either not installed, misaligned, or obstructed. See page 27.
    • Test the door for binding: Pull the emergency release handle. Manually open and close the door. If the door is binding or unbalanced, call for a trained door systems technician. If the door is balanced and not binding, adjust the DOWN (close) force. See Adjustment Step 2.


i try my level best to help you and to answer your question but perhaps not 100%.please rate my answer and click on helpful button.me here to help you any time.
Thanks

Related LiftMaster LA500 Manual Pages

Solar Gate Access System Daily Cycle Chart Manual - Page 1

...Solar panels should be two 20W (12V) panels in series. 100 75 30 11 200 32 0 195 116 79 60W SOLAR PANEL 50 169 92 57 NOTE: 100 143 69 37 ...batteries in an open area clear ...28 NOTE: 40W would be located in the given and standby time. LA500 Solar Gate Access System Daily Cycle Chart The LA500 Solar Gate Access System utilizes an Solar panel(s) must be two 20W ...
"Manufacturer's Certification for Credit" Manual - Page 1

... • www.liftmaster.com MANUFACTURER'S CERTIFICATION FOR CREDIT FOR RESIDENTIAL ENERGY EFFICIENT PROPERTY QUALIFIED UNDER INTERNAL REVENUE CODE SECTION 25D Name and...LiftMaster CSW24V Commercial DC Swing Gate Operator System (Duel Gate Model CSW24V) LiftMaster LA500 DC Swing Gate Operator System (Single Gate Model LA500-1PKG) LiftMaster LA500 DC Swing Gate Operator System (Duel Gate Model LA500...
LA500 Manual - Page 1

... use on pedestrian passage gates. UL325 compliant UL991 compliant THIS PRODUCT IS TO BE INSTALLED AND SERVICED BY A TRAINED GATE SYSTEMS TECHNICIAN ONLY. Visit www.liftmaster.com to locate a professional installing dealer in Class I, II, III and IV vehicular swing gate applications. This model is intended for use in your area...
LA500 Manual - Page 4

... for use in plain view on a single-family residence (UL325 Class I single family dwellings, or a garage or parking area associated therewith. Both primary and secondary entrapment protection methods must have warning signs placed in a... which unauthorized access is installed on both the open and close directions of motorized gate systems. 2 UL325 MODEL CLASSIFICATIONS II IV
LA500 Manual - Page 9

...• Test the gate operator monthly. Pedestrians MUST use ONLY LiftMaster part 29-NP712 for vehicles ONLY. For continued protection against fire... NEVER let children operate or play with national and local electrical codes. Keep the remote control away from children. • ALWAYS .... Failure to the operator or in BOTH the open and close gate cycles. The gate MUST reverse on a ...
LA500 Manual - Page 11

... limit switch - FIRE DEPARTMENT OPEN: accessory connection - EXIT, with gate moving - CLOSE LIMIT: OFF at close limit - OPEN, CLOSE, or STOP: accessory connection and on-board button - GATE MOVING: ON with Fail Open/Fail Close selection • Quick-Close ON/OFF selection switch • AC Fail Open/Battery selection switch • Low Battery Open/Close selection switch • Anti...
LA500 Manual - Page 27

... set properly the operator will automatically exit limit setting mode. ! SET OPEN SET CLOSE XM T ER NE WOR OPEN CLOSE STOP MOVE GATE R L AS T BE N MT SO ) 10 1 2 5 6 STATUS NPUT POWER BA T CHARG NG IMER ATE MOVI G B TT LOW ACC PWR OVL D AGNOST C CODES IRE D EX T S ADOW C OSE E INT RR J5 O J5 + INPU US 4 SET...
LA500 Manual - Page 28

... slightly clockwise. 3 Perform the "Obstruction Test" after every force setting adjustment (see below). LIMIT AND FORCE ADJUSTMENT + OBSTRUCTION TEST TEST 1 BUTTONS TER TWORK RSAL RCE OPEN CLOSE STOP SET O EN SET C OSE XM T R N TW R MOVE GATE ST TUS LS T BG MT S C ND ) 0 2 5 0 O N UT OW R A T C ARG G 80 MER A E MO I COD S SA CO E E NT...
LA500 Manual - Page 29

..., y compris une interférence pouvant causer un fonctionnement non souhaité. Choose a programming option: REMOTE CONTROLS (NOT PROVIDED) + ERASE ALL CODES OPEN CLOSE STOP LEARN BU XMITTER NETWORK SAL S T OP N SET CLOSE MOVE GATE OFF ON R ES OB I LMT 10 ST P 1 2 5 60 ER E WO K S ATUS NP T POW R B TT HAR I G N TT OW C PWR V D AG...
LA500 Manual - Page 30

... the Timer-to remain open, open the gate. 28 B D ! If the remote control is activated while the gate is in the closed manually. RELEASE 1 Insert the key into the lock. 2 Turn the key counter-clockwise 180°. 3 Turn the release lever counter-clockwise 180°. The next command given by a LiftMaster remote control or...
LA500 Manual - Page 31

... is suggested that the incoming voltage to put primary operator into High Band Learn Mode (the operator will beep if programming is at the open " or "closed . Register the LiftMaster Internet Gateway. Use an internet enabled computer or smartphone to the operator if it is within range and the operator will beep as...
LA500 Manual - Page 32

... the network. Power K Switched ON with expansion board connected. See Adjust Limits section. See Adjust Limits section. The STATUS LEDs are diagnostic codes for dual gates. OPEN CLOSE STOP SET OPEN SET CLOSE MOVE GATE OFF ON PRESS & RELEASE TO BEGIN LIMIT SETUP 1 2 (SECONDS) 10 5 60 XMITTER NETWORK STATUS: OFF INPUT POWER TIMER 180 MIN...
LA500 Manual - Page 34

... to stop and reverse. Open blinks 3 times, Close blinks 6 times, and Stop blinks once. ON: When CLOSE EYES/Interrupt loop is 163,000.). ADDITIONAL FEATURES EXPANSION BOARD OVERVIEW EXPANSION BOARD OVERVIEW To AVOID damaging the circuit board, relays or accessories, DO NOT connect more than 42 Vdc (32 Vac) to close. warning light or sounder...
LA500 Manual - Page 37

... B U RED S LAR / C ARG R + D ES T A A M 3-Button Remote Control programmed for OPEN, CLOSE, and STOP. Set the Close Limit Only Set the Open Limit Only 1 Press and release the SET OPEN and SET CLOSE buttons simultaneously to enter limit setting mode. 1 Press and release the SET OPEN and SET CLOSE buttons simultaneously to enter limit setting mode. 2 Press and hold...
LA500 Manual - Page 38

... is not set . Programming mode active. LIMIT SETUP LEDS GREEN XMITTER LED DIAGNOSTIC CODES LEDS STATUS LEDS OPEN CLOSE STOP SET OPEN SET CLOSE MOVE GATE OFF ON PRESS & RELEASE TO BEGIN LIMIT SETUP 1 2 (SECONDS) 10 5 60 XMITTER NETWORK STATUS: OFF INPUT POWER TIMER 180 MIN MAX BATT LOW ...
LA500 Manual - Page 40

... control/ transmitter to the gate post. Control board powers up, but motor does not run and diagnostic LED not on. a) Use Diagnostic code to identify issue b) Check all Open and Close inputs for a "stuck on" input c) Check Stop button is not "stuck on" d) Check Reset button e) Charges batteries by AC or solar power...
LA500 Manual - Page 41

... an active detector f) Battery voltage must be 22.0 Vdc or higher. Vehicle Interrupt loop does not cause gate to open. Replace defective Interrupt loop detector a) Use Diagnostic code to -Close (TTC) setting b) Check all Open inputs for an active input c) Check all Entrapment Protection Device inputs for an active sensor d) Check all vehicle detector...
LA500 Manual - Page 44

...VA STANDARD CONTROL BOX Field Wiring Wh te White Purple Black Red Antenna OPEN CLOSE STOP SET OPEN SET CLOSE MOVE GATE OFF ON PRESS & RELEASE TO BEG N LMT SETUP 1...180 MIN MAX BATT LOW BATT CHARG NG GATE MOV NG ACC PWR OVLD D AGNOST C CODES SBC "F RE DEPT" OPEN EX T SHADOW CLOSE EYES/ NTERRUPT + + (-) (+) (+) (-) Edge Photoelectric Sensors Photoelectric Sensors Field Wiring Edge ...
LA500 Manual - Page 45

... Red Orange Transformer 200 VA Field Wiring Edge Edge Antenna Coaxial Antenna Cable OPEN CLOSE STOP SET OPEN SET CLOSE MOVE GATE OFF ON PRESS & RELEASE O BEG N LMT SETUP 1...180 MIN MAX BATT LOW BATT CHARG NG GATE MOV NG ACC PWR OVLD D AGNOST C CODES SBC "F RE DEPT" OPEN EX T SHADOW CLOSE EYES/ NTERRUPT + + (-) (+) (+) (-) Photoelectric Sensors Photoelectric Sensors J5 N O COM ...
LA500 Manual - Page 46

...extension kit allows the antenna to satisfy your authorized LiftMaster dealer for Large Metal Control Box) 44 Model ...car as it approaches and will then open and locks when the gate is closed. Model SOLPNL10W12V (requires 2 minimum) ...replace original batteries provided with operators manufactured by entering a 4-digit code on a specially designed keypad. Two identical 12 Vdc batteries are...

Similar Questions

Garage Door Opens After Shutting.
My Lift master 8550 inside keypad is Inside wall pad is model #880LM. outside keypad Model # is 877M...
(Posted by BONNIECA92 2 years ago)
Programming Home Link
I am trying to program my home link in my ram truck. The button says training and trained but will n...
(Posted by dzulli 4 years ago)
Does It Have Myq And If So Can Garage Door Be Opened/closed From A Remote Locati
does it have MyQ and if so can garage door be opened/closed from a remote location with smart phone
(Posted by neilgoldschmitt 7 years ago)
No Power To Unit
Apparently I need an entrapment device hooked up to my LA500 to get it to run - where can I find one...
(Posted by tx1ton 9 years ago)
Ask a New Question
Use the box below to post a new question about this LiftMaster product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

LiftMaster Manuals

Find free LiftMaster LA500 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

LiftMaster Reviews

View thousands of LiftMaster user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete LiftMaster customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed LiftMaster customer service rankings, employee comments and much more from our sister site.