Get support for LiftMaster LA400

LiftMaster LA400 Support Question

LiftMaster LA400 Support Question

Find answers below for this question about LiftMaster LA400.
Need a LiftMaster LA400 manual? We have 3 online manuals for this item!
Question posted by nackroach on December 19th, 2011

Bracket To Make The La 400 Open More Than 100 Degrees

Is there A brack out the to make the LA 400 open more than 100 degrees When the gate is not at a 90 with the roadway

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related LiftMaster LA400 Manual Pages

LA400 Manual - Page 2

...-to-Open) Attach Brackets to Gate Operator Determine Mounting Location Measuring and Marking for the Gate Bracket Position Gate Operator on Gate Test Gate Travel Secure Post Bracket to Gate Post Secure Gate Bracket to Gate Warning Sign Placement Standard Control Box Large Metal Control Box (XLM) WIRING Connect the Gate Operator (Gate 1) to the Control Box Set the Bipart Delay (Model LA400-S Only...
LA400 Manual - Page 3

..., arranged or configured to four single family dwellings, or a garage or parking area associated therewith. NOTE: UL requires that the installation...gate within the operator. COMMERCIAL/GENERAL ACCESS VEHICULAR GATE OPERATOR II A vehicular gate operator (or system) intended for use in a commercial location or building such as a gate edge can be used for use on both the open...
LA400 Manual - Page 5

... horizontal plane parallel to the roadway, between a fixed object such as a wall, pillar or column, and a swing gate when in Section 4.1.1.1, the distance between a appropriate gate type listed, refer to ASTM F2200 for shall be guarded or covered. VEHICULAR HORIZONTAL SLIDE GATES fixed object when the gate moves toward the fully open position shall not exceed...
LA400 Manual - Page 6

.... • Flooded lead acid batteries will interfere with local electrical codes. To prevent SERIOUS INJURY or DEATH from a moving gate and RIGID objects, such as posts. • A swinging gate shall NOT open and close gate. • NEVER use force adjustments to do so may come near the operator MUST NOT be cleared and secured...
LA400 Manual - Page 8

... Operator. For Primary (Gate 1) and Secondary (Gate 2) installation the carton inventory is doubled except for a 90° opening 4 Minutes -20° C to + 50° C -4° F to -Open Bracket (1) • Hex ...Gate Width: Maximum Gate Weight: Protection Class: Travel Speed: Rated Operating Time: Temperature: Main Supply (Control) Dedicated Circuit: Absorbed Power: Protection Fuse Battery: 100...
LA400 Manual - Page 10

... Hinge Post Bracket Operator Operator Cable Antenna Control Box with Batteries Hinge Post Bracket Gate Bracket PVC Conduit ... to reduce the risk of entrapment or obstruction exists at either the opening or closing direction. INSTALLATION » OVERVIEW OF TYPICAL INSTALLATION LEFT-HAND GATE Warning Sign Antenna Control Box with Batteries Photoelectric Sensors 12 Gauge Wire...
LA400 Manual - Page 11

... the risk of nuisance tripping, such as when a vehicle trips the sensor while the gate is still moving. 10 INSTALLATION » OVERVIEW OF TYPICAL INSTALLATION DUAL GATE Warning Sign Hinge Antenna Post Bracket Gate Bracket Gate 1 Control Box with Batteries Operator Cable Gate 2 Junction Box Extension Cable Photoelectric Sensors PVC Conduit (not provided) to reduce the risk...
LA400 Manual - Page 13

... of installation you will damage the operator. 1 LEFT-HAND GATE RIGHT-HAND GATE Release Lever OR DETERMINE POSITION OF THE "OPTIONAL" PUSH-TO-OPEN BRACKET (NOT PROVIDED. INSTALLATION » MANUAL RELEASE + DETERMINE POSITION OF THE PULL-TO-OPEN BRACKET + DETERMINE POSITION OF THE "OPTIONAL" PUSH-TO-OPEN BRACKET MANUAL RELEASE 1 Insert the key into the lock and turn...
LA400 Manual - Page 14

... to operator using pins and hairpin clips. 2 Attach gate bracket to -Open kit 50-19503. ASSEMBLE GATE POST BRACKET (PULL-TO-OPEN) 1 Assemble gate post bracket by placing Pull-to-Open bracket on the following pages display a typical Left-Hand Gate installation. INSTALLATION » ASSEMBLE GATE POST BRACKET (PULL-TO-OPEN) + ATTACH BRACKETS TO GATE OPERATOR All the illustrations on top of post...
LA400 Manual - Page 15

... back page of the post brackets: • Paper template (Located on page 11 for the Pull-to determine the appropriate dimensions for the ideal mounting location. Refer to the illustrations to -Open bracket. INSTALLATION » DETERMINE MOUNTING LOCATION + MEASURING AND MARKING FOR THE GATE BRACKET DETERMINE MOUNTING LOCATION The gate post bracket assembly can be mounted several...
LA400 Manual - Page 16

... (arm) must be mounted several places on gate for mounting options. 1 Open the gate to desired open position (no greater than 100°) and hold operator against gate. 2 Place the operator arm against gate post at the desired position. Temporarily secure gate post bracket with washer, lock washer and nut. 1 3 4 7" (18 cm) 7" (18 cm) Hex Bolt 3/8" 5 Washer Lock Washer...
LA400 Manual - Page 21

... FORCE GATE 2 ON OFF AUTO OPEN LOW BATT OFF MAX OFF MSIANXGLE BUTTON OFF TIMER TO CLOSE C OPEN SINGLE BUTTON RESET OFF MAX STOP CTRL PWR CTRL PWR SHADOW INTERRUPT CHGR OVLD CTRL PWR AC PWR /SOLAR EARTH GROUND ROD INSTALLATION (REQUIRED) It is 2 The control box can be removed by opening the door 90°...
LA400 Manual - Page 31

... programming times-out automatically after 60 seconds of the control box to start over. PROGRAM CLOSE 6 Press the Gate 1 left button to move gate to open position and the fully closed position. DIAGNOSTIC GATE 1 SET CLOSE 7 When gate is made during the installation process. If a mistake is in the desired closed position, press the LEARN...
LA400 Manual - Page 39

...NO NC PHOTO S1 K2 DIAGNOSTIC GATE 1 K1 Q9 SET OPEN LIMIT SET CLOSE LIMIT LEARN LIMITS R2Ø7 Z2&#...reflector and mounting brackets +24 Vdc SENSING EDGES DESCRIPTION Miller MG020 2-wire electric edge for optional devices Make sure the rubber ...seal around the cover is complete. 38 Do not exceed 500mA with 115 Vac power supply or 300mA with the LA400...
LA400 Manual - Page 43

...14. BATTERY INPUT #1 16. FORCE SET 24. BATTERY INPUT #2 17. MASTER GATE JOG 20. CLOSE EDGE 3. SECOND - Reset Limits OPEN PHOTO EYE 5. FAULT ALARM OUTPUT 15. MASTER OPERATOR ARM CONNECTION 1 ANTENNA CONNECTION 13....NO NC PHOTO 2 S1 F3 K2 18 19 DIAGNOSTIC K1 Q9 SET OPEN LIMIT 20 GATE 1 SET CLOSE LIMIT LEARN LIMITS R2ÿ 7 Z2ÿ R227 J18 R224 ...
LA400 Manual - Page 46

...-rebuilt parts at no cost to you . THIS LIMITED WARRANTY DOES NOT COVER ANY PROBLEMS WITH, OR RELATING TO, THE GARAGE DOOR OR GARAGE DOOR HARDWARE, INCLUDING BUT NOT LIMITED TO THE DOOR SPRINGS, DOOR ROLLERS, DOOR ALIGNMENT OR HINGES. ANY SERVICE CALL THAT DETERMINES THE PROBLEM HAS BEEN CAUSED BY ANY OF THESE ITEMS COULD RESULT...
LA400 Push to Open Addendum Manual - Page 1

... dimensions (Figure 2). 4. Insert 3/8" hex bolt through middle hole. Mount gate bracket to actuator side of Gate Hinge Figure 3 Pin Hex Bolt Post Bracket Push-to-Open Bracket Flat Washer Lock Washer Nut Hairpin Clip 5/16" Hex Bolt 7-3/4" 90° 7-3/4" Special Post Pivot Bracket for Push-to -Open Bracket Post Bracket 3/8" Flat Washer 3/8" Lock Washer 3/8" Nut Center of operator with pin...
LA400 Push to Open Addendum Manual - Page 2

... board and mounting plate. 8. Close cover of post bracket slots (Figure 5). 10. NOTE: All four mounting holes must be level Fence Post Gate in OPEN Position Gate Bracket C Clamp Gate in retracted position, clamp bracket to gate post with 5/16" carriage bolts, flat washers, lock washers and nuts. 13. Remove brackets from electrocution, DISCONNECT electrical power to persons use...
LA400 Pull to Open Addendum Manual - Page 1

... be mounted several places on site conditions) DETERMINE MOUNTING LOCATION The gate post bracket assembly can be approximately 7" x 7". Place opener against gate post and adjust the opener until the required dimension is being added to 30-degrees of this hole helps add up to the LA400, offering greater mounting flexibility. Typical 4" Post Hole NOTE: The addition of...
LA400 Pull to Open Addendum Manual - Page 2

... Clip C-Clamp Disengage the operator by inserting the key and rotating the handle (Figure 3). Move the gate manually to brackets with pins and clips provided (Figure 2). Attach operator arm to the fully open and fully closed positions. Figure 3 Figure 4 01-33464 ©2006, The Chamberlain Group, Inc. It is extremely important that the...

Similar Questions

I Have Installed A Chamberlan Garage Door Opener And The Remote I Was Using Is
I have been using a Chamberlan garage door opener and its remote has been defective since of late.Pl...
(Posted by donweera42 8 months ago)
Garage Door Opens After Shutting.
My Lift master 8550 inside keypad is Inside wall pad is model #880LM. outside keypad Model # is 877M...
(Posted by BONNIECA92 2 years ago)
La 400 24v Dual Gate Swing Control Board K001a6039
Is there a version of this control board that has two "learn xmitter" buttons to allow only one gate...
(Posted by saritav 12 years ago)
Ask a New Question
Use the box below to post a new question about this LiftMaster product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

LiftMaster Manuals

Find free LiftMaster LA400 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

LiftMaster Reviews

View thousands of LiftMaster user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete LiftMaster customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed LiftMaster customer service rankings, employee comments and much more from our sister site.