Question posted by controlsystemgate on September 14th, 2014

Kpr2000 Keypad Error When Card Number On Block Program

scan one keyfog it is ok try to program block error when type card # 5 command for block 10 for id and # ok next card number # beep beep beep error. 510#101# beep x 3 510#0101# error 510# 00000101# error too. DELFIN, CONTROL SYSTEM GATE

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related LiftMaster KPR2000 Manual Pages

KPR2000 Waterproof Keypad/Proximity Reader Manual - Page 1

123 456 789 *0# WATERPROOF KEYPAD/PROXIMITY READER MODEL KPR2000 TABLE OF CONTENTS INTRODUCTION 2 FEATURES 2 ACCESSORIES 2 CARTON INVENTORY 2 SPECIFICATIONS 2 INSTALLATION 3 INSTALL THE KPR2000 3 CHOOSE AN OPERATION MODE 3 WIRING 4 WIRE THE KPR2000 4 PROGRAMMING 5 CONFIGURE THE KPR2000 5 PROGRAM CARDS AND PINS 6 ADVANCED PROGRAMMING 7 PANIC CODES 7 ALARM 8 SOUND & LIGHT ...
KPR2000 Waterproof Keypad/Proximity Reader Manual - Page 2

... offers advanced programming features like; KPR2000 Keypad/Proximity Reader/Controller Security Screwdriver (T-10 Security Torx Driver) 2 Operation is a single entry multi-function Access Controller with Part 15 of indoor, outdoor, and harsh environments. It can also be programmed to accept inputs from, or provide output to 2000 users in 125 KHz card reader supports industry standard...
KPR2000 Waterproof Keypad/Proximity Reader Manual - Page 3

... method) and manual entry of Wiegand data. • Card + PIN: The User must present a valid Wiegand Card to the KPR2000 in order to an external controller. PASS-THROUGH OPERATION The KPR2000 passes all keypad and card reader Wiegand data to be granted access. The facility code and the ID number are three different Access Configurations listed below: •...
KPR2000 Waterproof Keypad/Proximity Reader Manual - Page 4

... Pink Green (Data 0) White (Data 1) Pink (must connect for Alarm Contact Input Door/Gate Contact Input (Normally Closed) WIRING EXAMPLES: Gate/Door Operator or Fail-Secure Strike Magnetic Lock or Fail-Safe Strike Normally Open Install a 1N4007 or equivalent diode. KPR2000 External Alarm (1 Amp Maximum) Common Blue Purple Red Gray Pink Black 123 456...
KPR2000 Waterproof Keypad/Proximity Reader Manual - Page 5

... engaging or it can be changed at one block of your application (optional). Exit Program Mode Keystroke Combination ✱ (Master Code) # 6 0 # 6 1 # (Alarm sounds for 10 minutes after 10 failed card/PIN attempts. Control LED OR 2. The facility code and the ID number are 3 types of the output relay on activation. Enter Program Mode 2. DOTL Alarm ON OR 2. Enter...
KPR2000 Waterproof Keypad/Proximity Reader Manual - Page 6

... Card. • Keypad PIN: The PIN can be enrolled 3. Add Card: Using Auto ID (Allows KPR2000 to assign Card to user ID number OR 2. Add a PIN Assigns PIN to next available User ID number) OR 2. By User ID OR 2. Delete Card -By Card Number 3. PROGRAMMING 5 Program Cards and PINS. Programming will clear cards and PINs 2 (Read Card) # Requires the user card. IMPORTANT: User IDs...
KPR2000 Waterproof Keypad/Proximity Reader Manual - Page 7

...User ID Number) # (PIN) # 2 (User ID Number) # 3. Add a User Card OR 2. Enter Program Mode 2. This is a form of Auto User ID enrollment and is executed from outside of Program Mode. Add PIN Keystroke Combination ✱ (Master Code) # 1 (Read Card) # OR 1 (User ID) # (Read Card) # ✱ ✱ (Read Card) (1234#) (New PIN #) (New PIN #) This operation is a section of the KPR2000...
KPR2000 Waterproof Keypad/Proximity Reader Manual - Page 8

... OUR TOLL FREE NUMBER: 1-800-528-2806 © 2012, The Chamberlain Group Inc. ADVANCED PROGRAMMING Alarm TO RESET THE ALARM Programming Step Keystroke Combination To reset the door forced open warning (Read valid card) OR (Master Code #) To reset the door open too long (DOTL) warning (Read valid card) OR (Master Code) # ANTI-TAMPER ALARM The KPR2000 uses an optical...

Similar Questions

I Have Installed A Chamberlan Garage Door Opener And The Remote I Was Using Is
I have been using a Chamberlan garage door opener and its remote has been defective since of late.Pl...
(Posted by donweera42 8 months ago)
If I Have A Keypad On Both Sides Of A Gate, Do I Need To Program Both Separately
I have inherited a gate with a keypad on both sides of a gate. I've figured out how to program codes...
(Posted by travis25763 1 year ago)
Garage Door Opens After Shutting.
My Lift master 8550 inside keypad is Inside wall pad is model #880LM. outside keypad Model # is 877M...
(Posted by BONNIECA92 2 years ago)
How Do I Hook The Kpr2000 Up To A Chamberlain?
how do I hook up a kpr2000 to a chamberlain Liftmaster professional lgo
(Posted by 1gonejosh 2 years ago)
Ask a New Question
Use the box below to post a new question about this LiftMaster product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

LiftMaster Manuals

Find free LiftMaster KPR2000 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

LiftMaster Reviews

View thousands of LiftMaster user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete LiftMaster customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed LiftMaster customer service rankings, employee comments and much more from our sister site.