I Plug In Power Cord An Triggers Breaker On Plug How Can I Fix Problem

The person who posted this question about this LG product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related LG LB8000R Manual Pages

Owners Manual - Page 2

... care on the side of your receipt to this page in accordance with the air conditioner. • When the power cord is to be replaced, replacement work shall be performed in the event you may not need it to common problems in the chart of purchase or for service at all. Hardware Installation 5. READ THIS...
Owners Manual - Page 3

... may cause fire and electric shock. I Installation WARNING Always install the expansion panel(s). • No installation may cause explosion or fire. Do not place the power cord near flammable gas or combustibles such as shown below. ENGLISH Safety Precautions Precautions To prevent injury to the user or other people and property damage...
Owners Manual - Page 4

...will cause electric shock or fire due to heat generation. ON ON Do not modify power cord length. • It will cause electric shock or fire due to heat generation. ... it may cause electric shock (See Installation Manual). Do not use an unspecified power cord. • It will cause electric shock. Always plug into a grounded outlet. • No grounding may cause fire and electric shock...
Owners Manual - Page 5

and burn. Hold the plug by age or wear. • If leaving appliance damaged, there is running. Ventilate before operating air conditioner when gas goes out. • It will cause failure of...of machine • It is not designed to run into electric parts. Sharp edges Turn off the main power switch when not using it out. • It may cause injury. • It may cause failure ...
Owners Manual - Page 6

... the power cord and take care so that the cord should not be exposed to clean. Do not drink water drained from the socket. Do not use this appliance for special purposes such as pets, foods, precision machinery, or objects of fire or electric shock. Contact service center after taking the power-plug out from air conditioner...
Owners Manual - Page 7

... can destroy the insulation, leading to clean inside the air conditioner. There is a possibility of time. 2 Due to your authorized service dealer. 7 Cleaning and maintenance 1 Do not use water to possible electric shock. 2 When cleaning the unit, first make sure that the power and breaker are turned off. Service For repair and maintenance, contact...
Owners Manual - Page 8

Operating Instructions Remote Control Operations The remote control and control panel will look like those represented in the following pictures. Cool Energy Saver F1 LOW F2 MED F3 HIGH 'F 6 Fan Dry Timer TEMP 2 MODE TIMER FAN SPEED POWER 3 5 4 1 Power 1 Temp 2 Fan Speed 4 Timer Mode 5 3 8
Owners Manual - Page 9

...86°F (16°C~30°C). Select dry mode for dry operation. 4 FAN SPEED SELECTOR For increased power while cooling, select a higher fan speed. 3 steps: High ➔ Low ➔ Med 5 ON/... Operations 1 POWER Operation starts when this button is not going to be used for an extended period of time Keep the remote control away from the remote control if the air conditioner is pressed ...
Owners Manual - Page 10

...backward or forward. Adjusting horizontal air flow Adjusting vertical air flow • Recommended orientation of the air conditioner's louvers. OPEN the vent to maximize cooling efficiency. 10 Adjusting the Air Flow Direction Part A Airflow can also increase the cooling efficiency of the air conditioner. • Adjusting Horizontal Air Flow Direction Adjusting the vertical louvers...
Owners Manual - Page 11

...filter in the direction away from the back of the air conditioner. Drain pipe 11 Drain cap When pressing the drainpipe ...air conditioner. Air Filter The air filter behind the inlet grille should be below 40°C (104°F). 5 Rinse off and gently shake off excess water from the top for easy maintenance after installation. 2 Open the inlet grille by pulling off and unplug the power plug...
Owners Manual - Page 12

... using 2 screw holes, and lead out the power cord through slit "B". AIR FILTER 4. POWER CORD 11. Power Cord A Power Cord B 12 COMPRESSOR 12. CONDENSER 15. VERTICAL AIR DEFLECTOR (HORIZONTAL LOUVER) 7. CABINET 2. FRONT GRILLE 3. HORIZONTAL AIR DEFLECTOR (VERTICAL LOUVER) 9. REMOTE CONTROLLER Installing the Power cord You can choose between two methods below according...
Owners Manual - Page 13

...slightly lower than the front (about 30"~60" above the floor level. Restriction of outside of the air conditioner. ENGLISH How to the outside. 5 Install the unit with actual opening of 15" from the ...will prevent heat radiation of the upper sash to the window stool. 23" to the outside air will force condensed water to flow to Install the Unit 1 To prevent vibration and noise, make...
Owners Manual - Page 16

... outside (See Fig. 5). Type C 7 Fig. 6 10 Slide the unit into window stool. 8 Pull each window sash track, and repeat step 2. There is dry. Screw(Type A) Power cord Screw (Type A) Fig. 7 11 Cut the Foam-Strip to add water if the pan is no need to the proper length and insert between the...
Owners Manual - Page 17

... grounding prong from the plug. See ELECTRICAL DATA for attaching power cord to use an extension cord, use of room air conditioner is now completed. ENGLISH 12 Attach the Window Locking Bracket with 3-prong grounding plug Standard 125V, 3-wire grounding receptacle rated 15A, 125V AC Use 15 AMP, time delay fuse or circuit breaker. Push the grille in...
Owners Manual - Page 18

..., we strongly discourage the use a CSA certified/UL-listed 3-wire (grounding) extension cord, rated at 15A, 125V. However, if you wish to use an extension cord, use of an adapter plug. The wall power outlet should be aligned with a three-prong (grounding) plug. The customer should have the circuit checked by a qualified electrician to the...
Owners Manual - Page 19

... on, you need to give the air conditioner some time to the "Care and Maintenance" section (p.11) of a power failure, set cool enough I The air filter is • Check the fuse/circuit breaker box and replace triggered the fuse or reset the breaker I The fuse is blown/circuit breaker is dirty. The air conditioner is caused by the condenser on...
Owners Manual - Page 40

...WARRANTY PERIOD ABOVE. THIS LIMITED WARRANTY DOES NOT APPLY TO: 1. Damages or operating problems that result from misuse, abuse, operation outside environmental specifications or contrary to the original ...Prove Warranty Coverage Retain your Sales Receipt must be borne by the consumer. LG ROOM AIR CONDITIONER LIMITED WARRANTY - will repair or at the time warranty service is good only to the...

LG Knowledge Base Results

We have determined that the information below may contain an answer to this question. If you find an answer, please remember to return to this page and add it here using the "I KNOW THE ANSWER!" button above. It's that easy to earn points!

  • Dryer: Power Issues - LG Consumer Knowledge Base
    ... the door to the terminal block appropriately depending on ? On electric models ensure the power cord is completely plugged into the outlet.  Also, if the load size is the case, correct this... or if a fuse has gone out. Also, make certain that the power cord is installed correctly. Check the breaker box to disengage [child lock] can hinder proper airflow and prevent proper drying...
  • Not cooling entire unit - LG Consumer Knowledge Base
    ...160;a refrigerator without damaging the unit. To recover refrigerator from compressor to power on Refrigerators Check power cord to 5 seconds. (On a LFX and LMX Model the left side door ...be moved on a dedicated circuit breaker and that all the way and that there is no damage to stabilize in the refrigerator once it is plugged in Crisper drawer VIDEO Refrigerator: ...
  • LG Room / Window AC General FAQ - LG Consumer Knowledge Base
    ... breaker. Does the packing foam need to remove the drain hose plug in order to start to drain more power in order to restart the machine. ANSWERS: Many factors should I choose the right air conditioner for your home will not run until the ice is installed improperly or due to gauge the temperature of the cord...

Similar Questions

My Ac Will Not Work And When I Unplugged It And Plugged Back In The Power Cord D
The reset cord does not light up but there is power to plug in. Ac will not come on no power
(Posted by lORAINE123 3 years ago)
Power Cord Replacement Problem
I took the power cord off my LG LWHD2500ER wall A/C unit to find a replacement and now that it's in ...
(Posted by eacrary 7 years ago)
Replace The Power Cord For Model#hblg1453e.
I cannot figure out how to remove or install a new power cord. Where can I buy one?
(Posted by misst14 12 years ago)
Ask a New Question
Use the box below to post a new question about this LG product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

LG Manuals

Find free LG LB8000R manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

LG Reviews

View thousands of LG user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete LG customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed LG customer service rankings, employee comments and much more from our sister site.