Question posted by mrsrobinsonlj on August 26th, 2015

How Do I Turn Off The Energy Star Saving Mode?

The person who posted this question about this Hunter product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Requests for more information

Request from catdog2022 on July 23rd, 2022 2:11 PM
Did you figure out how to override the energy star settings on Hunter 44860 thermostat? Some people need it to be a little cooler than the 73 limit set by energy star. They seem to let you do this in manual mode but not on the programmable mode.

Current Answers

Answer #1: Posted by TommyKervz on August 26th, 2015 7:49 AM
This answer was accepted by the poster of the original question.
TommyKervz

Member since:
January 10th, 2013

Points: 17,776,813
1,090
points


Hope that is helpful.
Kervz at www.satechhelp.co.za

Related Hunter 44860 Manual Pages

Owner's Manual - Page 2

Touchscreen Programmable Thermostat Model 44860 2 Stage Heat/2 Stage Cool installation and operation manual
Owner's Manual - Page 3

... OPERATING INSTRUCTIONS 21 DATE & TIME SETTINGS 22 SYSTEM SETTINGS MENU 27 USER SETTINGS MENU 31 TEMPERATURE RANGE 34 ENERGY STAR DEFAULT PROGRAMS 35 MANUAL OPERATION 36 PROGRAM OPERATION 39 PROGRAM OVERRIDES 46 ADDITIONAL FEATURES 56 CLEAN SCREEN 56 CHANGE FILTER 60 ENERGY MONITOR FUNCTION 64 TROUBLESHOOTING 68 WIRING DIAGRAMS 72  44002-01 r051807
Owner's Manual - Page 4

Thank you for complete operating instructions.  44002-01 r051807 Touchscreen Programmable Thermostat Model 44860 2 Stage Heat/2 Stage Cool Congratulations! Please read this manual before beginning installation and save this booklet for choosing a Hunter programmable thermostat. Your new Hunter thermostat will provide years of reliable service and year-round energy savings.
Owner's Manual - Page 8

...electrical connector, such as you disconnect them. Turn the system power OFF at the furnace. (Failure to turn off the power to the existing thermostat before removal could damage your system.) 2. After... electrical tape.) 44002-01 r051807  Remove the existing thermostat cover to access the wires from the wall. (Some thermostats may have multiple covers, screws or other locking devices ...
Owner's Manual - Page 12

...: HEAT PUMP SYSTEMS label the wire with this sticker: if your existing thermostat is marked: label the wire with this sticker: Y1 / Y2 Compressor Stage 1 or 2 Y1 Y2 Y2 Y1 C 24 VAC Common C C O W2 Auxilliary Heat W2 W2 O Cool Mode Powered Reverse Valve O G Fan G G E Emergency Heat E E R/RC R / RC 24 VAC Power Supply...
Owner's Manual - Page 27

...temperature is within 2°F (1°C) above and below the set to run longer; a lower number will turn on the next stage based on the SPAN setting or 30 minutes, which ever comes first. If the ... be adjusted if your system is cycling too fast or too slowly. SETTING the span The SPAN setting mode in the SYSTEM SETTINGS MENU allows you to 30, the system will decrease your cycle time by the ...
Owner's Manual - Page 35

By using the preprogrammed and default settings, this thermostat can save you money by optimizing energy usage in heating and cooling. 30o F (0o C) 45o F (7o C) 95o F (35o C) 99o F (37o C) Out of Range "LO" 99o F 34 44002-01 r051807 TEMPERATURE RANGE This thermostat meets ENERGY STAR guidelines for energy efficiency.
Owner's Manual - Page 36

If customizing your programs, you can revert to the Energy Star Default Programs Chart shown below by pressing the icon in the program mode. 10 pm Program 4 Heat : 60o F (16o C) Cool : 82o F (28oC) Program 3 Heat : 68o F (20o C) Cool : 78o F (26o C) 4 pm 6 am Program 1 Heat : 68o F (20o C) Cool : 78o F (26o C) 8 ...
Owner's Manual - Page 37

SET HEAT OR AC SYSTEM MODE MAY 17 2006 THURSDAY 1 2 3 5 6 47 36 44002-01 r051807 NOTE: PROGRAMS PER DAY must be set to operate their thermostats manually, adjusting settings as needed. MANUAL OPERATION Many people prefer to 0 for manual operation. See USER SETTINGS MENU (pages 31-33).
Owner's Manual - Page 40

...Daytime Evening Nighttime 44002-01 r051807 39 Press to exit Program Mode at any period icon to see pages 31-33. PROGRAM OPERATION CREATING CUSTOM PROGRAMS You can program the thermostat to automatically adjust the temperature and airflow up to the ... PER DAY setting must be set to 2 or 4 in increments of inactivity during programming, the thermostat returns to four times per day.
Owner's Manual - Page 42

Touch the icon. Touch one of the screen to each day selected. 5. Touch the or sign to select mode. 7. PRESS PRG TO PROGRAM appears at the top of the display. (Image P2) 4. SELECT ICON TO PROGRAM appears at the top of the display along ...
Owner's Manual - Page 44

... fan mode (ON, AUTO, or REFRESH). 12. Repeat instructions 1-12 to select new days and time periods to be programmed or press to save the settings... for programming. 13. 9. Touch repeatedly to adjust numerals. Touch the temperature display to set the selected period to the main display. 44002-01 r051807 43 Touch to save programs and return to Energy Star...
Owner's Manual - Page 46

... set interval if the system does not cycle on . PROGRAM: Fan is on for one of the fan modes: ON: Fan runs continuously regardless of the touch screen. Scroll through the fan settings with the or sign...screen. Touch the icon. Touch to return to select one hour. Touch a blank area of the system mode. 1. NOTE: If the fan is touched, it will bring up the SET FAN screen. 44002-01 ...
Owner's Manual - Page 63

... BATTERIES USED UP warning flashes on the display and the system turns off until three new AA alkaline batteries are installed. The system remains off . If the batteries become too weak for normal operation, the thermostat enters the second battery power shortage mode. CHANGE BATTERIES The CHANGE BATTERIES warning indicates two stages of...
Owner's Manual - Page 64

... r051807 63 AUTO RECOVERY The AUTO RECOVERY FUNCTION allows heating and cooling systems to gradually recover from an energy-saving set point temperature to the next program setting. When the thermostat is in AUTO RECOVERY mode, the display flashes alternatively SYSTEM IN AUTO RECOVERY and the weekday. AUTO RECOVERY calculates the time needed to...
Owner's Manual - Page 67

... drops below 40°F (4°C). AUTO CUT-OFF AUTO CUT OFF automatically turns the system off . ERROR MESSAGE ERROR mode indicates an expected operation problem. You must reset and the thermostat by replacing the batteries if the thermostat has entered ERROR mode. NOTE: If the HVAC system has malfunctioned, the systems no longer respond to...
Owner's Manual - Page 68

RESETTING THE UNIT To restore the thermostat to the original factory settings, enter the SYSTEM SETTINGS MENU and set Option 12 to rapid cycling. See page 27. 44002-01 r051807 67 COMPRESSOR PROTECTION After the system stops running in cooling mode, there is a 3.5 minute delay before it can be restarted to prevent compressor damage due to YES.
Owner's Manual - Page 69

... not appear. 1a. Check that the day setting is selected under the system settings in permanent override mode. 4c. Make sure the thermostat is set properly to see if the correct furnace type is correct. 68 44002-01 r051807 Check to... in options. 3. The auto fan feature does not operate properly. 2a. Reset the thermostat. 2. Replace the batteries. 4. My display is erratic. 3a.
Owner's Manual - Page 70

...circuit breakers and switches to ensure there is enough power to operate when the thermostat is installed between the RC and RH terminals. 6. If applicable, make ...may be as much as a 4-minute delay before the system turns on but does not stay illuminated. 6a. Wait. Replace batteries. 5e. Replace batteries. 7. Make sure the thermostat is closed properly. 5f. If your system has 4 wires,...
Owner's Manual - Page 71

If ERR message remains after battery replacement, then replace unit. 9. 8. The touch screen permanently reads SYSTEM ERROR. 8a. How do I just operate my thermostat manually? 9a. Manual operation instructions begin on page 38. 70 44002-01 r051807 Refer to page 66 for ERROR mode instructions.

Similar Questions

Ask a New Question
Use the box below to post a new question about this Hunter product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Hunter Manuals

Find free Hunter 44860 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Hunter Reviews

View thousands of Hunter user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Hunter customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Hunter customer service rankings, employee comments and much more from our sister site.

Hunter Recalls

Find comprehensive Hunter recall information updated hourly on RecallOwl.com.