Honeywell HE120 Support Question
Find answers below for this question about Honeywell HE120.Need a Honeywell HE120 manual? We have 1 online manual for this item!
Question posted by laptop12345 on March 15th, 2013
Wireing To The Power Supply
How do i wire the transformer to the power source so the drum only rotates when the blower is running
Current Answers
There are currently no answers that have been posted for this question.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Related Honeywell HE120 Manual Pages
Owner's Manual - Page 1
... STEP 1: Determine Best Location ...4 STEP 2: Install Humidifier ...5 STEP 3: Install Bypass Collar ...7 STEP 4: Install Bypass Duct ...9 STEP 5: Assemble Humidifier Drum ...10 STEP 6: Assemble Humidifier ...11 STEP 7: Install Drain ...13 STEP 8: Install Saddle Valve ...13 STEP 9: Install Water Line ...15 STEP 10: Install Humidistat ...16 STEP 11: Wiring ...19 STEP 12: Testing and Checkout ...20...
Owner's Manual - Page 2
HE120 BY-PASS DRUM HUMIDIFIER
UNPACKING THE UNIT
This box contains all of the parts necessary to familiarize yourself with these components.
• Humidifier Housing • Humidifier Cover
• Humidifier Pad
• Motor Plate
• Humidistat
• Float Valve (Installed on Humidifier Housing)
• Water Pan
• Humidifier Accessory Bag (Plastic Bag)
• Motor ...
Owner's Manual - Page 3
... Marker Wire stripper Utility knife Scissors
3
69-1860EF-01 outside diameter
plastic Overflow Tube (10 ft.) [Not Included] X Plug-in Transformer Y Duct Tape (10 yds...S Plastic Compression Sleeve T Brass Compression Sleeve
Z Wire Nuts (x4) AA 1/2 in . • Closed Drum End
• Open Drum End
HE120 BY-PASS DRUM HUMIDIFIER
• Bypass Duct (6 in . dia.
Owner's Manual - Page 4
... you can be connected to allow Bypass Duct mounting on the supply (warm air) or return duct.
Typical Humidifier installation locations.
69-1860EF-01
4 HE120 BY-PASS DRUM HUMIDIFIER
BEFORE YOU BEGIN
When Installing this Humidifier requires several steps. See Fig. 1. (The Humidifier is designed to either side of Bypass Duct is complete, check out product operation...
Owner's Manual - Page 5
...to correctly install the Humidifier. of Thermostat Wire is unique. of Plastic Water Tubing is long enough to connect the water supply (saddle valve) to the Humidifier. • Make ...HE120 BY-PASS DRUM HUMIDIFIER
3. In some cases, additional wire, tubing, or duct may need to start the cut in the middle of duct above the line and 8-1/2 in .
Draw a level line on the duct in Transformer...
Owner's Manual - Page 6
...01
6 See Fig. 6.
8. Mounting Humidifier. 12. Sheet Metal Screws in .
Marking Mounting Hole locations.
10. Remove the HE120 Humidifier Housing and pre-drill the mounting holes using two #8 x 3/4 in . Disassemble the Humidifier; Secure the bottom of the Humidifier Housing using a 1/8 in . Sheet Metal Screws. HE120 BY-PASS DRUM HUMIDIFIER
STARTING HOLE
MOUNTING HOLES
M13618...
Owner's Manual - Page 7
... recommended that the flat side of the circle.
HE120 BY-PASS DRUM HUMIDIFIER
STEP 3: INSTALL BYPASS COLLAR
WARNING
Hazardous Voltage. Bypass Collar on the duct so that all six mounting holes are over the duct. (If you are installing the optional damper, it is supplied with an optional damper to shut off air flow...
Owner's Manual - Page 8
... Collar and Damper, as shown in . Place the Damper into position and install using a 1/8 in the duct when closed is acceptable.
69-1860EF-01
8 HE120 BY-PASS DRUM HUMIDIFIER
4. See Fig. 10. Installing Optional Damper.
6. A small amount of the opening in .
Pre-drill the mounting holes using #8 x 3/4 in Figure 11. BENT UP EDGE...
Owner's Manual - Page 9
... using at least two #8 x 3/4 in . Can cause personal injury. Carefully stretch out flexible Bypass Duct between Bypass Collar and Humidifier.
HE120 BY-PASS DRUM HUMIDIFIER
3. See Fig. 14. drill bit.)
Fig. 12. Secure Bypass Duct to Humidifier using at least three #8 x 3/4 in . Connecting Bypass Duct to allow proper operation of the damper.)
9
69-1860EF-01...
Owner's Manual - Page 10
.... 18. Installing Spring Retainer. METAL TAB
SLOT IN CLOSED DRUM END
M13622
Fig. 16. Slide Open Drum End over Drum Shaft with round posts inside Humidifier Pad. See Fig. 18. Installing Closed Drum End.
2. Installing Humidifier Pad.
4. HE120 BY-PASS DRUM HUMIDIFIER
STEP 5: ASSEMBLE HUMIDIFIER DRUM
1. Slide Closed Drum End over Drum Shaft with round posts facing away from metal tabs...
Owner's Manual - Page 11
...Valve using a 1/2 in . wrench.
See Fig 20. "U" SHAPE FACES UP
HE120 BY-PASS DRUM HUMIDIFIER
5. Installing Bearing Bracket.
2. Fig. 22. Unscrew Float Valve Retaining Nut using ...Humidifier Housing to the Humidifier Housing on the opposite side of the
Humidifier Housing with recessed side of washer against the Humidifier wall. Make sure the "U" shape is connected. Place motor lead wires...
Owner's Manual - Page 12
... the bottom of the Float Valve. Correct Float Valve position.
HUMIDIFIER HOUSING WALL
FLOAT VALVE RETAINING NUT
FLOAT VALVE STEM
M13628
Fig. 27. DRAIN FITTING
FLOAT
M13626
Fig. 24. site side of the Humidifier on the oppo-
Insert the Drain Fitting into the bearing. See Fig. 27. HE120 BY-PASS DRUM HUMIDIFIER
MOTOR FLOAT VALVE
8.
Owner's Manual - Page 13
HE120 BY-PASS DRUM HUMIDIFIER
11. Push the Overflow Tube over copper tube using a utility knife. Fasten the Overflow Tube (can be used in the Humidifier.)
2. Failure to prevent movement and ensure downward slope. 5.
Turn handle counter clockwise until piercing lance is below the rubber gasket. M20177
Fig. 30.
Do not ...
Owner's Manual - Page 14
... to avoid
shock hazard. Shut off water supply and drain the line. 2. Drill a 3/16 in pipe. Brackets should be parallel. Open water supply. Turn the handle to prevent distorting tube. Place valve body over hole such that lance fits into the drilled hole in .
HE120 BY-PASS DRUM HUMIDIFIER
a. Tighten screws evenly -
For 3/8 in the...
Owner's Manual - Page 15
HE120 BY-PASS DRUM HUMIDIFIER
STEP 9: INSTALL WATER LINE
CAUTION
Water Hazard.
Place Brass Compression Nut over the Tubing. 3. ... into the saddle valve fitting. 5.
sion Nut with an 1/2 in . Properly secure water line along the route with the Humidifier is appropriate for your local building codes to length. (Do not cut tubing too short.) 8. copper tubing to prevent movement and...
Owner's Manual - Page 16
... ON SHADED AREA OF TEMPLATE. Installing Gasket.
69-1860EF-01
16
upstream from the Humidifier or the Humidifier Bypass Collar.
2.
GASKET M13607
Fig. 38. Duct Mounting (Recommended):
IMPORTANT If mounting...Drill four 7/64 in the center of the template. HE120 BY-PASS DRUM HUMIDIFIER
STEP 10: INSTALL HUMIDISTAT
WARNING
Hazardous Voltage. M13606
Fig. 37. DRILL FOUR 7/64 IN....
Owner's Manual - Page 17
...-01
hole in . HE120 BY-PASS DRUM HUMIDIFIER
9.
Push the Setpoint Dial knob onto the control shaft. above the floor on the Control Assembly. See Fig. 41. Drill a 3/8 in . tion and pull about 5 ft. Removing Humidistat Back Cover.
6. See Fig. 43. Installing Screw Terminals. 7.
Wiring Humidistat.
8. Run 18-gauge two-strand thermostat wire to Duct. 10...
Owner's Manual - Page 18
...wire and pull the wire through the hole.
10. drill bit. c. Screw the Control Assembly to the recessed area of the front of Humidistat and remove. Mounting Humidistat.
9. BASEPLATE
3/8 IN. HE120 BY-PASS DRUM HUMIDIFIER...the Back Cover of the Humidistat Cover. To assemble control for low voltage wiring with 3/8 in .
BASE PLATE SCREWS
BASE PLATE WITH CONTROL ASSEMBLY MOUNTED
M13634...
Owner's Manual - Page 19
... Run the 18-gauge two-strand Thermostat Wire from the Humidistat to the Transformer near a wall outlet and cut to length. (Leave adequate wire at both ends for connection.)
3.
HE120 BY-PASS DRUM HUMIDIFIER
STEP 11: WIRING
WARNING
Hazardous Voltage. At the Humidifier, connect the red and white conductors to the Humidistat.
2. ment (can use duct tape). 7. Disconnect power supply before...
Owner's Manual - Page 20
...clockwise to 1-3/8 in transformer. 3. Snap Humidifier cover into place. 9. HE120 BY-PASS DRUM HUMIDIFIER
STEP 12: TESTING AND CHECKOUT
1. Complete the following checklist: Humidifier is level. Bypass Collar is secured with Sheet Metal Screws. Damper is open (If installed). Control wiring was reviewed per wiring diagram. (Fig. 51). Water supply line has no...
Similar Questions
Drum Turns Even When The Furnace Stops Running
Am i suppose to plug the transformer into a regular outlet? The drum rotates when the furnace stops...
Am i suppose to plug the transformer into a regular outlet? The drum rotates when the furnace stops...
(Posted by laptop12345 11 years ago)
Wiring Schematic He120a1010 Whole House Humidifiers
Need to see the wiring hook up
Need to see the wiring hook up
(Posted by rwhinrichs 11 years ago)