Get support for Honeywell CT3200

Honeywell CT3200 Support Question

Honeywell CT3200 Support Question

Find answers below for this question about Honeywell CT3200.
Need a Honeywell CT3200 manual? We have 1 online manual for this item!
Question posted by laurieanddenis30 on October 4th, 2012

I Have A Ct3200-it's On Auto And Heat, And Doesn't Turn On.

There is no programming down. So it should stay on and shut off when it needs to be. The furnace isn't turning on. It is a two year old new furnace?

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Honeywell CT3200 Manual Pages

Owner's Manual - Page 1

... or call Honeywell Customer Relations at 1-800-468-1502. MagicStat® CT3200 Programmable Thermostat Installation and Programming Instructions Weekday/Weekend (5-day/2-day) Programmable Heat and/or Cool Low Voltage (20 to 30 Vac) Thermostat and Mounting Plate Model CT3200 Welcome to the world of Contents Installation 2 Programming 11 Operation 17 Change the clock for Daylight/ 17...
Owner's Manual - Page 2

... or call Honeywell Customer Relations at 1-800-468-1502. Multistage Heat Pump Heating and cooling are produced from the same outdoor unit (compressor) with radiator heat. Fig. 1 MERCURY SWITCH Recycling Thermostat If you are removing an old thermostat that include warm air furnaces and hot water. Heating/Cooling System Conventional Single stage systems that contains mercury in a sealed...
Owner's Manual - Page 3

.... Carefully unpack your heating and cooling systems are working properly. Save your receipt and make sure you install the new thermostat. Honeywell recommends Energizer®...heating/air conditioning contractor-the problem may persist after you have the following parts: • Thermostat and mounting plate • Labels • Screws and anchors • Installation and Programming...
Owner's Manual - Page 4

...to on the old thermostat (Fig. 3). Disconnect the wires from the old thermostat and wrap the wires around a pencil to the heating/cooling system, either at the furnace or at ... remove the old thermostat's mounting plate from falling back into the wall. Remove the old thermostat Fig. 2 Fig. 3 M20140 Fig. 4 M19086 WIRES THROUGH WALL OPENING 4 INSTALLATION M20133 a. c. Turn off power ...
Owner's Manual - Page 6

... can wait until the thermostat is set your new thermostat for your thermostat correctly for a warm air, gas, or oil heating system. F POSITION FUEL SWITCH F E C ADJUST SCREWS THROUGH HOLES TO SELECT OPERATION DESIRED HEATING SYSTEM FUEL SWITCH POSITION D WARM AIR A-IN B-IN F FURNACE HOT WATER A-OUT B-IN F BOILER 1 TURN ELECTRIC A-IN B-OUT E FURNACE 1 TURN W Y G R Rc FUEL...
Owner's Manual - Page 7

...old thermostat wire with an efficiency rating under 90%. (The furnace efficiency rating should be on the new thermostat terminals, you might not need to the new thermostat. Type of the old wires to connect all of system Warm air, gas, or oil heating...on the old thermostat terminals do not match the letters on the furnace.) High-efficiency furnace such as shown in B-out one turn Fuel switch...
Owner's Manual - Page 8

... and negative terminals are now ready to page 12. 69-0653-6 Go to program the thermostat. Mount the thermostat Fig. 11 Fig. 12 a. Align the tabs at the top of the thermostat with the tabs at the top of the thermostat and heating/cooling system. b. M20130 Step 7. c. Make sure that the System switch is set in...
Owner's Manual - Page 9

... extra wires attached to the C or C1 terminals that do not connect to your old thermostat, do not allow the clock to avoid damaging your 3200 thermostat. a. b. Your 3200 thermostat will not interfere with your new thermostat. Contact your heating/cooling system is turned off the wires with electrical tape and place them . Wires that are not connected...
Owner's Manual - Page 10

..., H2 Y2 R* Rc* W Y G Do not continue installation Do not connect Do not continue installation. Old thermostat terminal Connect to wire the new thermostat. You have a single stage heat pump or zoning system. Fig. 15 JUMPER (FACTORY- See page 2 for cooling Heat Cooling Fan Changeover in cool (O terminal) or changeover in 5-wire systems. 10 INSTALLATION 69-0653...
Owner's Manual - Page 11

... LEAVE RETURN SLEEP 4 Time Temp 3 Set clock/Day Ahead Warmer Run Program 2 Set Schedule Back Cooler Hold Temp 1 Fan Auto On System Cool Off Heat Descriptions 1 Fan switch-Selects automatic fan operation or fan on (page 17) 9 2 Set Schedule-Puts the thermostat into programming 10 mode (page 14) 11 3 Set Clock/Day-Sets the clock...
Owner's Manual - Page 12

...). Fig. 18 d. Set the current time and day a. Press once. Fig. 19 Step 2. Learn about the programming features Your 3200 thermostat allows you to two program periods for both a heating season and a cooling season. • During the heating season, you can set the normal room temperature higher and the energy-saving temperature lower. • The...
Owner's Manual - Page 13

.... When available Weekdays and weekend Weekdays only Weekdays only Weekdays and weekend Programming tips • You do not need to bed. Use of sharp fingernails or pencil points can set up an... going to program times and temperatures for all program periods. If you decide not to leave your thermostat, it will remain in effect until you reach the program 69-0653-6 PROGRAMMING 13 You ...
Owner's Manual - Page 14

... pressing or until the desired temperature is displayed (Fig. 20). for the next program period (Fig. 22) and repeat steps d. c. d. Program the heating schedule a. Set the System switch to program for your heating schedule. Press to display a blank schedule for each weekday program period. SLEEP 10:00 PM 62°F (16.5°C) Fig. 20 Fig. 21...
Owner's Manual - Page 16

...°F (10°C). to AUTO. Check out the system Verify that your heating system works a. Repeat steps 3c...thermostat may delay up to 5 minutes before turning on the air conditioner. Your heating system should start . e. Press until the setting is 10°F (6°C) below room temperature (Fig. 26). Set the System switch to HEAT, and the Fan switch to program...
Owner's Manual - Page 17

...Switch Fan Setting Result Auto On A single-speed fan turns on the back of your fan and the heating and cooling system. b.... furnace. Press once. Set the Fan switch first and then set the System switch. Auto is displayed. Note: In a heat-...on the bottom of the thermostat faceplate (Fig. 16 page 11) control the operation of the thermostat. 69-0653-6 OPERATION 17...
Owner's Manual - Page 18

... side of removing the old ones, you insert the new batteries within the month....year to prevent the heating/cooling system from shutting down due to begin reprogramming. Dead Replace the batteries immediately. Your heating/cooling system is not operating. Then see : Batteries are oriented correctly as possible, within 20-30 seconds of the batteries to reprogram the thermostat...
Owner's Manual - Page 19

...: A temporary change to the schedule. Hold a temperature indefinitely Use the Hold Temp feature when you want to maintain a constant temperature indefinitely, such as when you programmed resumes when the next scheduled program period is reached. The heating/cooling schedule that the change before making any changes to the temperature lasts for the current...
Owner's Manual - Page 20

... temperature Press to display the temperature that you programmed. Cancel a program a. Check programs Press repeatedly to the room temperature. A blank program schedule is displayed and the program is programmed for programming the heating schedule or programming the cooling schedule on pages 14 and 15. 20 OPERATION Fig. 29 Fig. 30 Fig. 31 69-0653-6 The display then...
Owner's Manual - Page 21

...batteries correctly. The display should come on. • Check the program times for the furnace to heat up and the fan to come on . • You have... thermostat. Reprogram if necessary. • Check that the AM and PM indications are correct. Contact a heating contractor for heat at the register. • If the temperature setting is higher than 88°F (31°C) during programming ...
Owner's Manual - Page 22

... you need additional assistance, call , please have the following information available: • Thermostat model number and serial code (located under the battery cover) • Type of heating/cooling system...warm or too cool • • The furnace cycles too frequently • or the system cycle length is too short or too long The thermostat's current setting • does not match the ...

Similar Questions

Ask a New Question
Use the box below to post a new question about this Honeywell product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Honeywell Manuals

Find free Honeywell CT3200 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Honeywell Reviews

View thousands of Honeywell user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Honeywell customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Honeywell customer service rankings, employee comments and much more from our sister site.

Honeywell Recalls