Get support for Hitachi NR90GC - 3-1/2

Hitachi NR90GC Support Question

Hitachi NR90GC Support Question

Find answers below for this question about Hitachi NR90GC - 3-1/2" Gas Powered Clipped Head Framing Nailer.
Need a Hitachi NR90GC manual? We have 1 online manual for this item!
Question posted by charlesthomson26 on March 2nd, 2013

Fuel Cell Connector

Looking To Buy Small Black Triangular Nozzle That Connects Fuel Cell To Nailer Dont Know Proper Name

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Hitachi NR90GC Manual Pages

Service Manual - Page 1

E025 Sept. 2005 SPECIFICATIONS AND PARTS ARE SUBJECT TO CHANGE FOR IMPROVEMENT MODEL NR 90GC Hitachi Power Tools GAS STRIP NAILER NR 90GC TECHNICAL DATA AND SERVICE MANUAL N LIST No.
Service Manual - Page 4

... hour 2-actioned nail feeding --- 1 --- We will enter the largest-scale clipped head (D-head) nailer market with the new Model NR 90GC gas strip nailer to expand our market share. SELLING POINTS Well balance New aggressive appearance Comfortable grip Fully charged in one hour 3. 1. APPLICATIONS Floor and framing Truss build-up, window build-up Subflooring and roof decking...
Service Manual - Page 5

Specifications (1) Gas nailer Model NR 90GC Driving system Reciprocating piston type Weight Dimensions (Length x Height x Width) Nail feed ...16" x 18-5/32" x 5-29/32") Standard accessories - For North America Lubricant oiler (A) (Code No. 885546) Fuel cell (Code No. 728980) Grease (Code No. 317918) - next, pull the trigger to drive the nail. For Europe Lubricant oiler (A) (Code No. ...
Service Manual - Page 8

... feeding Battery voltage Charge 7.2 V 1 h Applicable nails Dia. (Clip head) Length 3.0 mm --- 3.3 mm (0.120" --- 0.131") 50 mm --- 90 mm (2" --- 3-1/2") Fuel cell dimension 31.5 mm dia. x 167 Fuel cell life 1200 nails P 3.4 kg (7.5 lbs.) 310 mm x 343 mm x 110 mm (12-3/16" x 13-1/2" x 4-11/32") 37 nails (1 strip) Rear loading Tool not required Rubber Single action Provided 2-actioned...
Service Manual - Page 10

...outside or in a well ventilated place. • Do not breathe gas. • Keep away from temperatures over 50ûC < 120&#...GAS, for ex., sun radiation). • Do not damage, puncture or burn even after use. • In use . KEEP OUT OF THE REACH OF CHILDREN. EXTREMELY FLAMMABLE • Contents under pressure, keep container in Germany 40 g 80 ml DANGER - For Europe Fuel cell...
Service Manual - Page 12

... if irritation continues. When punctured, remaining propellant gas will be displayed in shop windows. Do not store together with water. Do not expose to an open the fuel cell. Observe temperature limit of children. Container under pressure. Do not store above 50ûC (120ûF), e.g. Transportation of small quantities for road; UN No.: United...
Service Manual - Page 13

... wiring connects the battery, trigger switch and fan switch. MECHANISM AND OPERATION PRINCIPLE 8-1. Mechanism The Model NR 90GC is no similarity between the Model NR 90GC and other Hitachi nailers in the cylinder. This is the Hitachi's first gas strip nailer and there is a nailer that of the main parts are fed from the fuel cell to...
Service Manual - Page 14

Output section Head section (Cylinder head section) Filter [4] Cylinder Head [14] Spark Plug (A) [11] Motor Spring [12] Fan [20] Combustion chamber Chamber [24] Motor Mount [8] Top Cover [3] Motor [6] Cell Cover [109] Cell Lever [105] Switch Lever (B) [114] Cylinder Ass'y [42] Housing Ass'y [74] Piston [39] Battery [111] Piston Bumper [40] Pushing Lever [64] Trigger [98] Feeder...
Service Manual - Page 15

...] pushes the back of the fuel cell to Combustion chamber O-ring [36] spray fuel into the nailer in the initial state. Chamber [24] Cylinder Ass'y [42] The Switch Plate [34] on Switch Lever (B) [114] to rotate it. Thus the combustion chamber is sealed by the O-ring [36] simultaneously. The Chamber Head [22] is sealed by...
Service Manual - Page 16

... Ass'y [42], combustion gas is partially released into the atmosphere through the Lead Valve [45]. Then the spark plug in the Cylinder Ass'y [42]. Spark plug Fuel burns and a sudden expansion...When the Trigger [98] is depressed, the Chamber O-ring [15] Lock Bar [100] at the bottom of fuel is almost completed. Chamber Lock Bar [100] Fig. 7 --- 13 --- Because the Lead Valve [45] is...
Service Manual - Page 19

... [64] without depressing the Trigger [98], then depress the Trigger [98]. Set the Battery [111] properly to occur. No fuel is not turned on . The switch of the fuel cell properly (Fig. 15). Set the fuel cell properly (Fig. 14). Press the Pushing Lever [64] securely. Use a new fuel cell. Top Cover [3] Filter [4] (Clean the Filter [4] with the Filter [4] clogged.
Service Manual - Page 20

... rotating it seals. Insufficient sealing of the cup and the stem in a thermal insulating material. --- 17 --- The nailer is not set properly. Replace the fuel cell with new one. Fig. 15 Checking the fuel cell Problem Possible cause Fuel is damaged. The bag in a liquid state. Press the stem five times or more with new one . Check...
Service Manual - Page 21

A large amount of fuel is under 1500 meters. --- 18 --- Remedy Use the nailer in a place such as highlands at an altitude of 1500 meters or more. Problem Fuel is low in a place where the altitude is sprayed. Possible cause Inspection method The oxygen content of the air is sprayed but no combustion occurs.
Service Manual - Page 22

... Motor [6]. --- 19 --- The Motor [6] does not rotate. Connection failure between Internal Wire (A) [86] and the Motor [6]. Break in gas nailers. Keep depressing the Trigger [98] securely until the nailing operation is damaged. The Adapter [30] is deformed. Remove the Battery [111] and set properly to the fuel cell. Charge the Battery [111]. Check the position of...
Service Manual - Page 29

...of the above operation, perform checking and take corrective actions as follows. (Disassemble and reassemble the nailer according to determine the cause of the Pushing Lever [64].) 4. Clean Spark Plug (A) [11... Wire (A) [86]. The battery is abnormal. (Replace the fuel cell with new one.) 2. Bolt M5 x 20 [13] and remove the Cylinder Head [14] from the cable due to rotate the Motor [6]. ...
Service Manual - Page 31

... oil (Gas Nailer Lubricant) ...14 (Black 95] Tapping Screw (W/Flange) D4 x 16 (Black 78] Tapping Screw (W/Flange) D4 x 20 (Black 83] Tapping Screw (W/Flange) D5 x 20 (Black 126]... (ATTOLUB No. 2) (Code No. 317918) to remove all nails, fuel cell and battery. When installing the O-rings, be sure to the areas shown... 0.7 to tighten the screw of the head securely before driving nails. 10-1. Bolt ...
Service Manual - Page 35

Bolt M5 x 14 [1] Handle section Fig. 24 --- 32 --- Spark Plug (A) [11] Spark plug cable Wiring connected to the motor Connector of the motor Cylinder head section Housing section Top Cover [3] (Do not open excessively.) Washer M5 [2] Hex. Socket Hd.
Service Manual - Page 40

Remove the Shaft Ring [26]. Remove the Adapter [30]. --- 37 --- (2) Disassembly and reassembly of the Top Cover [3] and the related parts [Tools required] Roll pin puller (2.0 mm (0.078") dia.) (a) Disassembly (See Fig. 29.) Remove the Filter Cover [5] and the Filter [4]. Then remove the Latch [106] and the ...
Service Manual - Page 72

...[125] is pulled backward. Press the Pushing Lever [64] against a workpiece with the battery, fuel cell and nails loaded for the following. Check that the piston returns to the top dead center by ... Trigger [98] partway to the bottom dead center. (2) Check the main body with the battery, fuel cell and nails. Check that no nail is rotating). Check that the Fan [20] is driven just ...
Service Manual - Page 76

...1 BRACKET 1 NYLON NUT M5 1 NAIL RAIL 1 MAGAZINE PLATE 1 TAPPING SCREW (W/FLANGE) D4X14 (BLACK) 3 PRISM 1 TRIGGER SPRING 1 TRIGGER 1 ROLL PIN D2.5X10 (10 PCS.) 1 CHAMBER LOCK... 1 PUSHING LEVER CONNECTOR 1 NAME PLATE 1 SCREW M5 4 HOUSING 1 INSULATOR SHEET 1 HITACHI LABEL 1 HOUSING ASS'Y 1 INCLUD. 70-72 NYLON NUT M4 1 HEX. TAPPING SCREW D4 1 CELL LEVER 1 LATCH ...

Similar Questions

Will Not Run
Why would the compressor hum then kick reset.
(Posted by PRUITT 3 years ago)
Nt65ga Will Not Fire
NT65GA Does not fire when trigger is pulled. Battery has full charge.
(Posted by dmcgeeoo6 7 years ago)
Hitachi Gas Strip Nailer
I AM TRYING TO FIND A PART CALLED A ,FUEL CELL ADAPTER
(Posted by scottmacaulay987 11 years ago)
Ask a New Question
Use the box below to post a new question about this Hitachi product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Hitachi Manuals

Find free Hitachi NR90GC - 3-1/2inch Gas Powered Clipped Head Framing Nailer manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Hitachi Reviews

View thousands of Hitachi user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Hitachi customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings