How To Replace Failed Disk P2000 Msa Disk Available Out Of Raid
The person who posted this question about this HP product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.
Current Answers
There are currently no answers that have been posted for this question.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Related HP P2000 Manual Pages
HP P2000 G3 MSA System CLI Reference Guide - Page 37
... is illuminated amber.
How Used ...
1.1
...
HP P2000 G3 MSA System CLI Reference Guide 37
Clear metadata from leftover disks. If spares are online and leftover disks exist. VDISK ...
... Improper use of the leftover disks to AVAIL, making the disk available for use this command when all vdisks are available, and the health of the vdisk, and the...
HP P2000 G3 MSA System CLI Reference Guide - Page 87
... and its status: # show vdisks
HP P2000 G3 MSA System CLI Reference Guide 87 NOTE: The only commands allowed for example, they failed), you must delete it again (to CRIT. a RAID-6 vdisk can be missing one disk; For example, a 16-disk RAID-10 vdisk can be missing one or two disks; Syntax dequarantine vdisk vdisk Parameters vdisk vdisk...
HP P2000 G3 MSA System CLI Reference Guide - Page 119
... the storage system will automatically designate an available compatible disk as a spare to write-through when CompactFlash memory fails. emp-poll-rate rate Optional. The interval between background vdisk scrub finishing and starting again is cleared. compact-flash-failure enabled|disabled|on |off Optional. Sets whether the cache policy automatically changes to replace a failed disk in...
HP P2000 G3 MSA System CLI Reference Guide - Page 125
...disk before signaling the host
that the write is complete.
Read ahead can , however, specify a different stripe size for any volume at the time you create, these default stripe sizes are made. HP P2000 G3 MSA... ahead is written to the disks. The controllers treat non-RAID and RAID-1 vdisks internally as a fan failure. You can increase storage device speed during sequential reads. •...
HP P2000 G3 MSA System CLI Reference Guide - Page 289
...Flush to Disk
string
Shows whether host drivers are allowed to use a compatible disk as a spare to replace a failed disk in seconds at which the storage system polls... interval in a vdisk if no compatible spare is available.
• Disabled: The dynamic spares feature is disabled...; 0: Disabled • 4: Enabled
HP P2000 G3 MSA System CLI Reference Guide 289
This is the default. • Enabled:...
HP P2000 G3 MSA System CLI Reference Guide - Page 437
... and masking.
HP P2000 G3 MSA System CLI Reference Guide 437 See compatible disk.
Fibre Channel Arbitrated Loop (FC-AL) topology. A volume that provides SES data such as temperature, power supply and fan status, and the presence or absence of a disk that has been automatically excluded from a vdisk, and is enabled, to replace a failed disk in -time...
HP P2000 G3 MSA System Event Description Reference Guide - Page 4
... due to the failure of bad-block replacements available.
6
Warning Vdisk creation failed during initialization. The indicated disk had an uncorrectable error and the controller reassigned...failed and reports a product-specific diagnostic code. That spare is disabled, replace the failed disk and use SMU
to automatically reconstruct the critical vdisk. • Replace the failed disk for RAID...
HP P2000 G3 MSA System Event Description Reference Guide - Page 5
... Vdisk reconstruction failed. Storage Controller firmware update has completed.
Recommended actions
• Determine whether the reconstruction failed due to a disk problem and whether replacing that a problem reported by a user, or succeeded. Recommended actions • No action required.
21
Warning Vdisk verification failed during the verification process.
HP P2000 G3 MSA System...
HP P2000 G3 MSA System Event Description Reference Guide - Page 9
... module is bad, replace the indicated device.
Recommended actions • No action required.
61 Error
The controller reset the indicated disk channel to recover from another initiator or target.
Recommended actions • You may need to clear the disks' metadata if you want to non-Active-Active controllers. HP P2000 G3 MSA System Event Descriptions Reference...
HP P2000 G3 MSA System Event Description Reference Guide - Page 21
...RAID 0 or non-RAID vdisk
When the scrub is complete, event 207 is logged. If a disk fails data may be logged with no parity errors, or it was aborted by a user. If so, replace those disks... vdisk scrub in all cases.
HP P2000 G3 MSA System Event Descriptions Reference Guide 21 Warning Parity errors found that at risk.
Warning A scrub-disk job logged with event 208 has completed...
HP P2000 G3 MSA System Event Description Reference Guide - Page 42
...
feature was enabled but no properly sized disk was available. The status of the vdisk that originally had the failed disk status is Good. All data in the SMU reference guide. If the power-on in a RAID-1, 3, or 5 vdisk; Event 8 reports a media error for a Replace the disk. Event 8 reports that disk to identify vdisk members after restarting or...
HP P2000 G3 MSA System Event Description Reference Guide - Page 43
If this status occurs after you replace a defective disk with a known good disk, the enclosure midplane might have experienced a failure. HP P2000 G3 MSA System Event Descriptions Reference Guide 43 Replace the enclosure.
Table 1 Disk error conditions and recommended actions (continued)
Condition
Recommended action
The status of the vdisk that originally had the failed disk is DRV ...
HP P2000 G3 MSA System SMU Reference Guide - Page 21
... of similar size. • For greatest reliability, use if disks fail. Dedicating spares to vdisks is to replace the failed disk and is available, reconstruction cannot start. Best practices for access by using parity-protected RAID levels.
HP P2000 G3 MSA System SMU Reference Guide 21 The storage system presents only volumes, not vdisks, to controller host ports for creating...
HP P2000 G3 MSA System SMU Reference Guide - Page 33
... compatible spares are available, the storage system automatically uses the spares to be used by a different critical vdisk than the smallest disk in a redundant vdisk (RAID 1, 3, 5, 6, 10, or 50) and compatible spares are available, reconstruction does not start reconstruction manually, replace each failed disk and then do one or more disks fail in the vdisk. HP P2000 G3 MSA System SMU...
HP P2000 G3 MSA System SMU Reference Guide - Page 47
.... Click Apply. A compatible disk has enough capacity to replace the failed disk and is enabled, the system checks for SMART events one minute after the next rescan and automatically disables SMART for all of 79 bytes, using characters except double quote or backslash. If a dedicated spare, global spare, or compatible available disk is already present, the...
HP P2000 G3 MSA System SMU Reference Guide - Page 51
...>
System Utilities. 2. HP P2000 G3 MSA System SMU Reference Guide 51 Vdisk-level errors reported include: hard errors, media errors, and bad block replacements (BBRs). Background vdisk scrub ...disk defects during scrub. For RAID 1 and 10, the utility compares the primary and secondary disks to find data inconsistencies. For NRAID and RAID 0, the utility checks for both SATA and SAS disks...
HP P2000 G3 MSA System SMU Reference Guide - Page 83
...)" for event messages to be expanded and the maximum number of disks the vdisk can stop expansion only by adding disks to it, up to complete, depending on the vdisk's RAID level and size, disk speed, utility priority, and other processes running on the storage system. To send a test message 1. You can take hours or...
HP P2000 G3 MSA System SMU Reference Guide - Page 85
...write-locked, its disks is detected as described in Configuring background scrub for NRAID or RAID-0 vdisks; HP P2000 G3 MSA System SMU Reference Guide...missing disks come online and the vdisk status becomes FTOL (fault tolerant and online), or if after the storage ...data loss.
if known-failed disks are :
• At system power-up, a vdisk has fewer disks online than a background...
HP P2000 G3 MSA System SMU Reference Guide - Page 91
... one missing disk but resolve the problem as soon as secondary events. 4. You can use a degraded RAID-6 vdisk but remains fault tolerant. Viewing information about the event. For descriptions of existing vdisks.
You can use the vdisk but is not available. • Name. Date and time when the event occurred, shown as replacing a disk. Degraded.
HP P2000 G3 MSA System SMU Reference Guide - Page 151
... feature that is automatically assigned, if the dynamic spares option is written to a vdisk member before moving to replace a failed disk. An available compatible disk that monitors disk activity in the storage system and spins down (DSD) dual-port disk dynamic spare EC
EMP explicit mapping FC global spare host image ID
IQN iSCSI iSNS jumbo frame leftover...
Similar Questions
How To Reset A Hp P2000 Msa Cli Password To Default
(Posted by psci1qaz2w 10 years ago)
Can You Start Management Controllers For P2000 Msa From Telnet
(Posted by radspra 10 years ago)
Automatic Fail Over In Left Hand Hp P4300 Storages?
I configured HP P4300 Storages. Fail over can be done manually but not automatically? So what are th...
I configured HP P4300 Storages. Fail over can be done manually but not automatically? So what are th...
(Posted by jayakrishnavallepu4 12 years ago)