Question posted by uselrph on September 8th, 2013
How To Replace A Broken Pressure Air Release Valve On A De Pool Filter
The person who posted this question about this Hayward product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.
Current Answers
There are currently no answers that have been posted for this question.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Related Hayward Perflex Manual Pages
Models: EC65A EC75A - Page 3
... a finite life, the cover/grate should be in accordance with strainer cover lock ring.
Before servicing pool and spa circulation system, filters manual air relief valve must be inspected frequently and replaced at more suction outlets per pump must be damaged, broken, cracked, missing, or not securely attached. Electrical Ground motor before connecting to a gas supply line...
Models: EC65A EC75A - Page 4
... Perflex's exclusive "BUMP" action, the D.E.
Self-priming pumps can no longer efficiently remove dirt from a lower level and prime automatically.
All plumbing connections on the system are covered later.
4. then, using the optional Drain Valve Kit (Model SP0723) and an
SYSTEM LOCATION
1. Connect the pool suction plumbing between the filter and pump.
5. If the pressure...
Models: EC65A EC75A - Page 5
... return valves (when used). Note and record the pressure gauge reading after each regeneration, and until the filter is allowed to the pool for ...FILTER
Close the filter drain and the vent valve. Prime and start the pump following the manufacturer's instructions.
PREVENTIVE MAINTENANCE
While Perflex filters are recommended for superchlorination and daily use other commercial filter...
Perflex EC40 - Page 1
... sealant to drain the used . PUMP SELECTION
To power your Perflex filter, select a continuous duty pump designed for convenient operation. Install the flow controller in its dirt holding capacity has been reached. Keep the filter "BUMP" handle, drain outlet, and pressure gauge accessible for swimming pool service. D.E.
All plumbing connections on a level platform or base...
Perflex EC40 - Page 2
...Filter Head Screw
12
Filter Head Nut
12
Washer
12
Tube Sheet (Top or Bottom)
2
Diaphragm Gasket
1
Flex-Tube™ Assembly
72
Tube Sheet Screw
12
Tube Sheet Nut
12
1-1/2" Ball-Type Drain Valve
1
Plug w/Gasket
1
Pressure Gauge
1
Flow Diffuser
1
Check Valve... pool by young children. ECX1035
DESCRIPTION
NO.
SPECIFICATIONS
MODEL NO. PARTS MODEL EC40 SERIES FILTER
...
Perflex EC40 - Page 3
... normal. BEFORE STARTING THE FILTER
1. WITCO Witco Corporation
2. STARTING THE FILTER
Close the filter drain and the vent valve.
Move the bump handle down slowly, then up in shortened filter cycles.
PREVENTIVE MAINTENANCE
While Perflex filters are recommended for more full turn. Air trapped in the system will eventually result in swimming pools, it . Screw the fitting...
Perflex EC40C90 Series - Page 2
...swimming pool, spa, or...REPLACE IF MISSING OR DAMAGED. The ANSI/NSPI 4 Standard (above -ground swimming pools and may result in a damp or non-ventilated location. Use a solid copper conductor, size or larger.
Perflex™ Extended Cycle Filtration System__________
PRODUCT REGISTRATION
(Retain For Your Records)
________
DATE OF INSTALLATION INITIAL PRESSURE GAUGE READING (CLEAN FILTER...
Perflex EC40C90 Series - Page 3
... Ground Fault Circuit Interrupter (GFCI).
If screws are lost, order replacement parts from pumps with damaged, broken, cracked, missing, or unsecured drain covers and suction outlets. Hazardous Pressure. Pumps, filters, and other equipment. Disembowelment, entrapment, or drowning is intended for pools and spas require two (2) functioning suction outlets at more than 30 PSI. Do...
Perflex EC40C90 Series - Page 4
...Information
Introduction
This manual contains information for swimming pool filtration. Instructions in a perfectly balanced, non-corrosive system. filter, simply move the unique "Bump" handle up pressure and decreases the flow, conventional filters require backwashing. Patented Flex-Tubes™ make the Hayward Perflex D.E. All Perflex™ Filtration models are combined on fresh or...
Perflex EC40C90 Series - Page 6
... by opening Air Relief Valve before starting pump. Superchlorinate the pool water by a Spacer Tube. Important Safety Instructions - Alternately tighten both Clamp Halves. Alternately tighten until Spacer Tube is engaged (approx. 100 in -line valves. WARNING - Pump and Filter System Operates Under High Pressure. Slide a Washer over the filter flange. To re-start the pump per...
Perflex EC40C90 Series - Page 7
... is recommended when the pressure gauge rises more than 10 psi (.70 Bar) in the system will take it. To clean, first stop the pump; Repeat 8 times. Open the suction and outlet valves (when used). Once air has escaped the filter and a steady
stream of water is returning to the pool, the filter is ready for...
Perflex EC40C90 Series - Page 9
...pressures.
Bump
Remedy
Bump-Drain-Recharge. Partially closed valve on suction side of pool dirt, algae, etc. Bump. Clean. Clean. Cleaning with pool dirt, algae, Bump-Drain-Recharge.
etc. Bumping incorrectly.
Pump output exceeds design flow rate of algae. Check GPM/LPM output.
Probable Cause D.E. Open valve. D.E.
Pump impeller vanes clogged.
Replace... filter GPM...
Perflex EC40C90 Series - Page 11
... Vent Valve
1
Filter Body with Flow Diffuser
1
Clamp Assembly with Hardware
1
Hardware Kit for Clamp Assembly
1
Shaft Kit
1
Bump Handle Grip-Noryl®
1
Bump Handle Screw Kit
1
Bump Shaft, 1/2"
1
Tube Sheet (Top/Bottom)
2
Diaphragm Gasket
1
Flex-Tube Assembly (EC40)
72
Tube Sheet Bolt Set
6
Plug with Gasket
1
Ball-Type Drain Valve with Nipple
1
Pressure...
Perflex EC50 - Page 1
...the filter as practical. Ball-style control valves are recommended.
3.
Through Perflex's exclusive "BUMP" action, the D.E. If the pump is going above -ground and on the EC50 filter are...filter so the tank can lift water from the filter when its proper position. IS50A-98
MODEL EC50 SERIES
The Perflex Model EC50 is a high performance swimming pool filter with other side of the filter...
Perflex EC50 - Page 2
... of the filter. (Note: If the filter is recommended when the gauge pressure rises more full turn. All suction and discharge valves must slope away from the pool water, the accumulated dirt causes a resistance to the pool, the filter is a steady flow of the handle.
3. Air trapped in STARTING THE FILTER and PRECOATING. The filter is the "precoat pressure." This is...
Perflex EC50C90 Series - Page 2
... AND REPLACE IF MISSING OR DAMAGED. WARNING - A storable pool is constructed so that it is strongly advised to protect the electrical components from external bonding lug to reinforcing rod or mesh.
Perflex™ Extended Cycle Filtration System__________
PRODUCT REGISTRATION
(Retain For Your Records)
________
DATE OF INSTALLATION INITIAL PRESSURE GAUGE READING (CLEAN FILTER PUMP...
Perflex EC50C90 Series - Page 3
...of a swimming pool filtration system operate under pressure. CAUTION - DANGER - Disembowelment, entrapment, or drowning is protected by a GFCI. Replace damaged, broken, cracked, missing,...air from pumps with all applicable local building codes. Suction from the system. Pumps, filters, and other equipment.
Provide a properly located outlet. Never use provided air relief valve...
Perflex EC50C90 Series - Page 4
... is normally fed into the system through the filter. Output pressure and flow are high performance, above-ground swimming pool filters. Instructions in a perfectly balanced, non-corrosive system. The Hayward Perflex System is initially started; The Perflex Filter System uses diatomite filter powder (commonly called D.E.).
is the most comprehensive clean, removing microscopic...
Perflex EC50C90 Series - Page 6
... by adding unstabilized granular or liquid chlorine. Start-Up & Operation
Starting the Filter
Close the filter drain and the vent valve. Air trapped in serious injury.
1. Perflex™ Extended Cycle Filtration System
Prior to the pool. Failure to do so could cause severe personal injury and/or property damage.
1. Make sure clamp is ready for more...
Perflex EC50C90 Series - Page 9
... and clean. Perflex™ Extended Cycle Filtration System
Troubleshooting
Problem Running at high pressures.
Overcharge of both 1 & 2.
Clean.
brisk up stroke.
Super-chlorinate; coated with a stiff wire brush through the pump strainer opening will usually work.
Consult pump and motor troubleshooting guide.
Check and straighten or replace. Open valve. Cleaning...
Similar Questions
How To Replace The Hayward Replacement Flex Tube Assembly Pool Filter For Ec65
(Posted by arcjoyin 10 years ago)
Video How To Replace A Manifold In A Hayward Pool Filter
(Posted by Pedifluk 10 years ago)
Pro-grid Filter Leaking At Base Of Manual Air Relief Valve
The filter is leaking at the top, at the base of the manual air relief valve. What would cause this,...
The filter is leaking at the top, at the base of the manual air relief valve. What would cause this,...
(Posted by lwallas 11 years ago)
Check Valve Ec75 Filter
How do I replace the check valve on my EC75 filter?
How do I replace the check valve on my EC75 filter?
(Posted by rkauffman 12 years ago)