Get support for Hayward Perflex

Hayward Perflex Support Question

Hayward Perflex Support Question

Find answers below for this question about Hayward Perflex.
Need a Hayward Perflex manual? We have 5 online manuals for this item!
Question posted by jtttw on June 13th, 2012

Pivot Pin In Ec40 Hayward Filter

how do you replace the pivot pin in the bump handle of a EC40 hayward de filter

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Hayward Perflex Manual Pages

Models: EC65A EC75A - Page 3

...replaced at more suction outlets per pump must be in violent separation of three feet (3') [1 meter] apart, as described above . Hazardous Pressure. Do not close filter manual air relief valve until a steady stream of 12 IS65ING Rev A - Before servicing pool and spa circulation system, filters...WARNING - WARNING - USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Pomona, CA Clemmons, NC...
Models: EC65A EC75A - Page 4

... covered later. 4. PUMP SELECTION To power your Perflex filter, select a continuous duty pump designed for convenient operation. Tighten pump base mounting bolts, if loose. 4. Securely hand tighten the union nut between the skimmer, pool outlet, and the pump. 6. If the pressure gauge is an alternate bump handle location on local electrical codes for information on...
Models: EC65A EC75A - Page 5

... and the vent valve. This is suggested. Repeat 3 times. Using a drift (or 10 penny nail), tap the pivot pin out of the filter head anchor point, freeing the end of operating chemicals, D.E., and a pool test kit. Obtain a supply of the handle. Follow chemical manufacturer's recommendations for a few seconds to the alternate position and align the...
Models: EC65A EC75A - Page 6

...O-Ring 1 4 ECX11194AT Filter Head with Vent Valve 1 5 ECX100Z9 Roll Pin 1 6 ECX4236A Bump Shoulder bolt Kit 1 7 Nut in bolt Kit 8 ECX1040 Bump Handle Assy w/pins, bolt & nut 1 9 ECX1037B Bump Handle Grip 1 10 ECX1642A ... Nest (EC75) 1 (Includes. 13thru 22) USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Pomona, CA Clemmons, NC Nashville, TN www.haywardpool.com Page 6 of 12...
Models: EC65A EC75A - Page 8

... tube nest in pool. (such as needed. Operating filter without D.E. D.E. ...Bump. Recharge as Cheer) and warm draining, and c. Bump handle bent. 4. Presence of water and out a steady stream. loaded to capacity with Short cycles -- (accelerated if chemicals are due to larger size fitting. muriatic acid solution (or filter USE ONLY HAYWARD GENUINE REPLACEMENT...
Perflex EC40 - Page 1

... on the EC40 filter are recommended. 3. Since 40 GPM (150 LPM) is the desired maximum filter flow, a flow controller (part number ECX1055) is the most units. FILTER LOCATION 1. Set the filter on the other side of the system. Keep the filter "BUMP" handle, drain outlet, and pressure gauge accessible for fresh or salt water swimming pools. Position the filter so...
Perflex EC40 - Page 2

...Bump Mechanism Cover 1 Filter Head w/Vent Valve 1 Filter Body w/Flow Diffuser 1 Vent Valve w/O-Ring 1 Thrust Washer 2 Bump Handle Assembly 1 Bump Handle Grip 1 Pivot Pin 1 Shoulder Screw 1 Locknut 1 Bump Shaft 1 O-Ring 2 Retainer 2 Filter Head Screw 12 Filter...PARTS MODEL EC40 SERIES FILTER REF. EC40 EFFECTIVE FILTRATION... and on-ground pools, advises that components...
Perflex EC40 - Page 3

...), tap the pivot pin out of the filter head anchor point, freeing the end of operating chemicals, D.E., and a pool test kit. Reinstall the bump cover and grip. Install the pool return plumbing. 7. CLEANING Cleaning is installed below the pool water line, close the suction and return valves) and allow water and dirt to 1 ratio; TO CHANGE BUMP HANDLE POSITION...
Perflex EC40C90 Series - Page 2

... GOOD CONDITION AND REPLACE IF MISSING OR DAMAGED. Do NOT use , it cannot be readily disassembled for storage. Use a solid copper conductor, size or larger. Perflex™ Extended Cycle Filtration System__________ PRODUCT REGISTRATION (Retain For Your Records) ________ DATE OF INSTALLATION INITIAL PRESSURE GAUGE READING (CLEAN FILTER PUMP MODEL HORSEPOWER FILTER MODEL SERIAL NUMBER...
Perflex EC40C90 Series - Page 4

...-connect union ƒ Modular platform base Perflex™ Filtration Performance Data Model No. The Hayward Perflex D.E. D.E. filter powder coats the tubes and traps dirt and impurities as a uniquely superior above-ground pool pump. filter, simply move the unique "Bump" handle up pressure and decreases the flow, conventional filters require backwashing. The system is normally fed...
Perflex EC40C90 Series - Page 5

... other side of the filter outlet. There is an alternate bump handle location on the system are covered later. To facilitate servicing of the filter system and to the right). Perflex™ Extended Cycle Filtration System Installation Instructions System Location For best pump performance, the system MUST be located below the pool water line (See Figure...
Perflex EC40C90 Series - Page 7

... of water is returning to the pool, the filter is now ready for a few seconds...filter. Repeat 8 times. Failure to flow. This is cleaned, there may be OPEN before and after the diatomite (D.E.) has been added. Perflex™ Extended Cycle Filtration System Start-Up & Operation Starting the Filter Close the filter drain and the vent valve. CAUTION - Move the bump handle...
Perflex EC40C90 Series - Page 8

... and the head anchor holes. Rotate the bump handle to eyes, skin, and clothing. After cleaning, thoroughly flush all affected parts with water that the mineral content in shortened filter cycles. Reinstall the bump cover and grip. Service & Repairs Consult your local authorized Hayward-Perflex dealer or service center. Perflex™ Extended Cycle Filtration System Start-Up...
Perflex EC50 - Page 1

...filter "BUMP" handle, drain outlet, and pressure gauge accessible for swimming pool service. It is going above the water line, a self-priming centrifugal pump must be used with a variety of Hayward...the filter is the most efficient dirt remover known. When the filter powder is designed for continuous operation, for easy servicing. 2. PUMP SELECTION To power your Perflex filter, ...
Perflex EC50 - Page 2

... the pump and let the filter fill with the pump off the handle. 2. Tap the pivot pin in the starting the pump. BEFORE STARTING THE FILTER 1. If desired however, drain piping may be performed directly into the thread hand tight; TO CHANGE BUMP HANDLE POSITION 1. Connect the pool suction plumbing between the skimmer, pool outlet, etc., and the pump...
Perflex EC50 - Page 3

...Bump Mechanism Cover Filter Head w/Vent Valve Filter Body w/Flow Diffuser Vent Valve w/O-Ring Thrust Washer Bump Handle Assembly Bump Handle Grip Pivot Pin Shoulder Screw Locknut Bump Shaft O-Ring Retainer Filter Head Screw Filter...-up in swimming pools, it is important to keep in mind that the mineral content in 1 to 1 ratio; PREVENTIVE MAINTENANCE While Perflex filters are basically resistant ...
Perflex EC50C90 Series - Page 2

...pool, spa, or hot tub. (In Canada use with hot tubs and spas if so marked. Perflex™ Extended Cycle Filtration System__________ PRODUCT REGISTRATION (Retain For Your Records) ________ DATE OF INSTALLATION INITIAL PRESSURE GAUGE READING (CLEAN FILTER PUMP MODEL HORSEPOWER FILTER... pool, spa, or hot tub, and to all times. The ANSI/NSPI 4 Standard (above -ground swimming pools ...
Perflex EC50C90 Series - Page 4

... Flex-Tubes™ make the Hayward Perflex D.E. When the accumulated dirt builds up and down a few times to filter components ƒ Power-Flo Matrix™ Series high-performance pump ƒ Quick-connect union ƒ Modular platform base Perflex™ Filtration Performance Data Model No. filter, simply move the unique "Bump" handle up pressure and decreases the flow...
Perflex EC50C90 Series - Page 7

... completes the cleaning phase. Proceed as the filter has been pre-coated. To Change Bump Handle Position 1. This is installed below the pool water line, close the suction and outlet valves) and allow water and dirt to empty completely. To clean, first stop the pump; Tap the pivot pin in tab at near the original flow...
Perflex EC50C90 Series - Page 11

Perflex™ Extended Cycle Filtration System Replacement Parts Parts Listing Ref. Operation 1 26 ...ECX5000D Bump Mechanism Cover 1 2 ECX1322A Vent Valve with O-Ring 1 3 ECX5000BP Filter Head with Vent Valve 1 4 ECX5000C Clamp Assembly with Spring 1 5 ECX100Z9 Pivot Pin (long) 1 6 ECX4236 Shoulder Screw 1 7 ECX1040 Bump Handle 1 8 ECX1037B Bump Handle Grip...

Similar Questions

How To Remove Pump Handle Pivot Pin
How do I remove pump handle pivot pin to replace pump handle?
(Posted by georgec2 10 years ago)
The Bump Handle Moves Up And Down Too Easily And Doesn't Regenerate The Filter.
I dissassembled and cleaned the filter. While dissassembled, the bump handle seemed to work, (It pus...
(Posted by multimom2003 11 years ago)
Ask a New Question
Use the box below to post a new question about this Hayward product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Hayward Manuals

Find free Hayward Perflex manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Hayward Reviews

View thousands of Hayward user reviews and customer ratings available at ReviewOwl.com.