Hayward HeatPro Support Question
Find answers below for this question about Hayward HeatPro.Need a Hayward HeatPro manual? We have 3 online manuals for this item!
Question posted by kodabu on January 19th, 2014
Is A Check Valve Required Between A Pool Heat Pump And Chlorine Generator
The person who posted this question about this Hayward product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.
Current Answers
There are currently no answers that have been posted for this question.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Related Hayward HeatPro Manual Pages
Heat Pro Owners Operations & Parts Manual - Page 2
...pool or spa, and to reinforcing rod or mesh. Though this product is constructed in or on the heat pump, pumps or filters. All electrical wiring MUST be caught in an opening of air for bonding requirements... and national codes and regulations. WARNING To reduce the risk of 22
HEATPRO HEAT PUMP
HP13023772 Rev: D
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS IN THIS...
Heat Pro Owners Operations & Parts Manual - Page 3
...and after pump shut off position and filter manual air relief valve must be in open position. WARNING - Do not operate pool and spa circulation system unless filter air relief valve body is...cracked, missing, or not securely attached.
Pregnant women should check the water temperature with the covers. Page 3 of 22
HEATPRO HEAT PUMP
HP13023772 Rev: D
o Dual suction fittings shall not be...
Heat Pro Owners Operations & Parts Manual - Page 8
... of rainwater, mixed with debris from the base when the heat pump is required to be forced through the unit. The troubleshooting section provides ...HEATPRO HEAT PUMP
HP13023772 Rev: D
A minimum of 2 feet (.6 m) of air.
The more humid the ambient air, the more than an hour, a leak in the internal plumbing may have occurred.
Drainage and Condensation
THE HEAT PUMP GENERATES...
Heat Pro Owners Operations & Parts Manual - Page 10
... the light above the "POOL" button (and "SPA" button for dual thermostat application) is flowing through the unit as setup by plugging in order for dual thermostat application) to start .
6. Keep all objects off the top of this heat pump if any damaged part of 22
HEATPRO HEAT PUMP
HP13023772 Rev: D
Operating the HeatPro Heat Pump
NOTICE-
When the unit...
Heat Pro Owners Operations & Parts Manual - Page 13
... the heat pump back in pool or spa mode press the up arrow button, down arrow button for sanitary swimming conditions as well as each unit will vary depending upon conditions surrounding the heat pump, clearance around the heat pump and heat pump maintenance. This will not allow the raw chlorine to drain back to the heat pump when the water filter pump is...
Heat Pro Owners Operations & Parts Manual - Page 17
... Pool Service Provider. If heat pump continues to cycle, turn unit off too quickly)
Low refrigerant, low ambient temp, or high humidity with low ambient temp
Check valve settings and ensure water flow is sufficient (is cycling (on .
Check evaporator coil for Hayward HeatPro Heat Pump
Problem Unit is not operating. Water is coming from bottom of 22 Troubleshooting
HEATPRO HEAT PUMP...
Heat Pro Owners Operations & Parts Manual - Page 18
... no water flow
Air flow obstruction
Check breaker and ensure that the unit is on and turn on . No action required. Wait 5 minutes Check water flow to owner's manual of 22
HEATPRO HEAT PUMP
HP13023772 Rev: D
Display Diagnostic Codes -
Call Pool Service Provider.
Refer to heat pump Clean the filter Make sure all valves are open and bypass is closed...
Heat Pro Installation - Page 3
... 104°F [40°C]. spa or hot tub thermostats may err in open filter manual air relief valve. Page 3 of 20
HEATPRO HEAT PUMP
HP13023770 Rev: E
o Dual ...check the water temperature with strainer cover lock ring. Before servicing pool and spa water circulation system, all National, State, and Local codes applicable. Do not change filter control valve position while system pump...
Heat Pro Installation - Page 4
... the need to exit the spa.
5. Plumbing connections: 2 inch PVC pipe Schedule 40 and 2 inch fittings and components as follows: (3) - 2 inch Isolation Valves (1) - 2 inch Check Valve (2) - 2 x 2 x 2 PVC Tee's
NOTE: Pipe fittings such as reducers, tees, and elbows cause pressure to drop as possible to exit the pool and into the pump circulating system.
Do not tamper...
Heat Pro Installation - Page 5
Page 5 of 20
HEATPRO HEAT PUMP
HP13023770 Rev: E
Hayward HeatPro Heat Pump Dimensions
MODELS: HP20654T, HP20654BT, HP20854T, HP20854BT and HP21104T
Hayward HeatPro Heat Pump Specifications
Operating Specification
Volts Hertz Phase Compressor Maximum Operating Current Compressor LRA Fan Motor Max Load (Amps) Fan Motor HP Minimum Circuit Ampacity Maximum Fuse ...
Heat Pro Installation - Page 10
...
Pomona, CA Clemmons, NC Nashville, TN
Tel: 908.351.5400 www.haywardpool.com POOL PUMP
FILTER
POOL HEATER
MANUAL ISOLATION VALVES
CHECK VALVE
CHEMICAL LOOP
CHEMICAL FEEDER
FROM POOL OR SPA
MANUAL BYPASS VALVE
TO POOL OR SPA
NOTICE -The heat pump must be adjusted to your system
and heat pump. Failure to be protected from back siphoning of water.
See instructions for water loss...
Heat Pro Installation - Page 11
... the condenser. A minimum flow of 75 GPM.
Check the entire piping system for a maximum flow rate of 30 gpm is designed for leaks.
Flow Rate
MODEL: HP20654T & HP20654BT
This heat pump is complete, operate the pool filter pump with a flow rate of 30 gpm is required to ensure sufficient heat removal from the condenser, thus avoiding overheating...
Heat Pro Installation - Page 14
... NOT ground to bond the heat pump can be generated by gas and solar units, isolating it with a shut-off
valve and a check valve when gas or solar heater is in operation protects the heat pump.
Because of the intense heat that will advise you are installing a heat pump in combination with any other type of heating device, please call the HAYWARD...
Heat Pro Installation - Page 18
... to the "Off" position and then back to Performance Monitoring Section of 20
HEATPRO HEAT PUMP
HP13023770 Rev: E
Start-Up Procedures
1. Allow 5 Minutes for system pressure to a temperature higher than the ambient air temperature.
Reference this installation manual to start :
a) Check water flow b) Ensure that a circuit breaker may be conducted ONLY by ensuring the...
Heat Pro Installation - Page 19
...high humidity with low ambient temp
Check valve settings and ensure water flow is sufficient (is the filter pump running continually?) If heat pump continues to cycle, turn unit ... . Check evaporator coil for service.
Water is coming from bottom of 20
HEATPRO HEAT PUMP
HP13023770 Rev: E
General Troubleshooting Guide for service. Otherwise there is only condensation. Check the ...
Heat Pro Installation - Page 20
... manual of 20
HEATPRO HEAT PUMP
HP13023770 Rev: E
Display Diagnostic Codes -Troubleshooting Guide for Hayward HeatPro Heat Pump
Display (blank)
Problem
No power to heat pump
Faulty electrical component
Possible Cause
Tripped circuit breaker/ no water flow
valve is closed . Page 20 of the remote device. Wait until pool needs heat. Call for service. Ensure pool filter pump is controlling...
Heat Pro - Page 4
... to run the heat pump for life. The HEATPRO pool heat pump is not in use a pool cover at night and when the pool is a self-contained unit designed specifically for buying a HEATPRO pool heat pump. All HEATPRO pool heat pumps have an electronic board with an effective, state-of heaters. During warmer weather, the pool cover may be required.
2
OWNER'S MANUAL
Occasionally...
Heat Pro - Page 8
.... The use of 90 degree bends and short radius elbows in the water piping should not be located at the very least all around your heat pump. The pool heat pump is designed for unrestricted air intake and service access.
72" 24"
24"
Service access 24" to prevent the possibility of 72 inches should be...
Heat Pro - Page 9
... of your pool heat pump should be performed by a qualified electrician in accordance with PVC glue. If the disconnect switch is turned off before opening the access panel.
CAUTION
The wiring of it. Water piping
? IMPORTANT
The piping sequence is as follows: pool > pool pump > filter > heater > check valve > chemical feeder > pool. Automated chlorine distribution systems...
Heat Pro - Page 10
... the heater, any automatic chlorine generator, and any other , and then to 8 foot solid copper rod must be placed before or upstream from the heat pump.
4. Any kind of ...flow. A 1/3 lb check valve must then be installed between the heater and any system with over a 3/4 HP pool pump. (see FIG.3 for ease of automatic chlorine distribution system must be bonded together....
Similar Questions
We Have A Heatpro Pool Heat Pump (november 2011)
We Are Getting A P5 Error Code. What Does It Mean? thank You. rose
We Are Getting A P5 Error Code. What Does It Mean? thank You. rose
(Posted by ropaul 9 years ago)
How Do You Repair A Summit Pool Heat Pumps
(Posted by ishoputira 10 years ago)
Heat Pump Works But Does'nt Heat The Pool
The heat pump is running (the fan sign is what we see) but it is not heating the pool
The heat pump is running (the fan sign is what we see) but it is not heating the pool
(Posted by Anonymous-60496 12 years ago)
Heat Pro Heat Pump - Winterizing
How do you winterize the Heat Pro heat pump
How do you winterize the Heat Pro heat pump
(Posted by pmicc 12 years ago)