How Do I Know The Chlorine Mix For A 35000 Gal In Ground Pool?

I am a first timer opening our pool.. I ha e everything ready, PH is reading good but how do I know the clarinet/water measurements to put in the barrells

Current Answers

Answer #1: Posted by SonuKumar on May 23rd, 2021 8:24 AM
This answer was accepted by the poster of the original question.
SonuKumar

Member since:
May 9th, 2021

Points: 16,637,180
1,100
points


Please respond to my effort to provide you with the best possible solution by using the "Acceptable Solution" and/or the "Helpful" buttons when the answer has proven to be helpful.

Regards,
Sonu
Your search handyman for all e-support needs!!

Related Hayward CAT-2000 Manual Pages

CAT 2000 - Page 1

CAT 2000 AUTOMATED CONTROLLER OWNER'S MANUAL INSTALLATION OPERATION MAINTENANCE SPECIFICATIONS
CAT 2000 - Page 2

... a water chemistry controller without proper filtration system recirculation. Properly preparing for performing and recording manual water testing...read this manual, it is presupposed that your new CAT controller is no more challenging than installation of the pool or spa to be used to answer any filtration system component, all valves required to eliminate pressure from the CAT 2000...
CAT 2000 - Page 3

... 10. TABLE OF CONTENTS Chemical Automation with the CAT 2000 Components of a CAT System Important Safety Information. Section 7. Section 11. Section 14. Section 8. Packaging Contents Standard Installation Installation Utilizing Bypass Line Preparing Pool or Spa Water Chemistry Setting and Operating the CAT 2000 Advanced (Dealer) Setup Mode Display Functions Maintenance Troubleshooting...
CAT 2000 - Page 4

... to the demand. SECTION 1. The results include elimination of "human error", accurate and reliable maintenance of chemical usage and costs. ILLUSTRATION 1. CHEMICAL AUTOMATION WITH THE CAT 2000 A pool operator typically checks and adjusts pool or spa water chemistry hourly at best.
CAT 2000 - Page 5

... ORP at 650 millivolts. If pH is preset from the pH and ORP probes, displays water quality readings in digital format, and activates chemical feeders in a typical CAT 2000 controller system: The Professional-Series pH Sensor samples water from the factory to the pool or spa surface can occur. The ideal pH range for mounting the pH, ORP and Flow Sensor while...
CAT 2000 - Page 6

... are a great aid in conformance with the controller. 10. WARNING - Read complete instructions prior to a grounding type receptacle protected by a ground-fault circuit interrupter (GFI). CAT Controllers recommends installation to the public. WARNING - WARNING - Never use an extension cord for manual water testing with these instructions and the contents of electric shock. CONTENTS...
CAT 2000 - Page 7

... to remove contents. Please report any shipping or handling damage immediately to Connect Sensors) (2) Sensor Storage Containers (1) CAT 2000 Owner's Manual The CAT 2000 Pro-Pack includes the following : (1) CAT 2000 Water Chemistry Controller (1) Professional Series pH Sensor with 24" Cable and BNC Connector (1) Professional Series ORP Sensor with Cable and Specialty Connector (1) 30...
CAT 2000 - Page 8

...upstream from any other related equipment. ALL RIGHTS RESERVED We recommend using a CAT Flowcell and fittings to pool or spa operator. C. Drill and tap a 1/4" NPT port at a location ...location subject to pass through the cell and across the sensors. Away from pool or spa. Remove pH and ORP sensors from filtration system. 2. Relieve pressure from the plastic storage...
CAT 2000 - Page 9

... to Suction) Rotary Flow Sensor Flow Flow Chemical Pump CAT CO2 or pH Control Flow Cell / Flow Sensor Bypass Line Flow Solenoid... as labeled. Connect chemical feeders to the controller unit as labeled. 12. CAT 2000 INSTALLATION DIAGRAM WITH FLOWCELL pH Sensor CAT 2000 ORP Sensor CAT 2000 CONTROLLER Chemical Pump Influent (to Return Line) Main Drain and Skimmer SUCTION LINE...
CAT 2000 - Page 10

... pool or spa. Turn off heater, chemical feeders, pump, and any other related equipment. Relieve pressure from bypass inlet valve. 7. C. Securely mount the CAT 2000 ... adjacent to pool or spa operator. B. E. Install in Illustration 3. 5. Select a convenient mounting location for all recreational water applications. Located a minimum of a CAT Flowcell and Rotary...
CAT 2000 - Page 11

CAT 2000 INSTALLATION DIAGRAM WITH BYPASS LINE CAT 2000 CAT 2000 CONTROLLER Chemical Pump pH Sensor Sensor Adaptor ORP Sensor Sensor Adaptor Chemical Pump CAT CO2 or pH Control Solenoid Flow Cell / Flow Sensor Bypass Line (Plumbed On-Site) Flow Flow Flow Sensor Flow Flow WASTE or Erosion Feeder Solenoid Main Drain and ...
CAT 2000 - Page 12

... residual readings relative to provide consistent sanitizer residual levels rather than consistent control of the pool or spa. CAT strongly recommends establishing desired pH, sanitizer residual, calcium hardness, total alkalinity, temperature and cyanuric acid levels prior to the following ranges before powering on ORP. All CAT water quality controllers maintain sanitizer levels (chlorine...
CAT 2000 - Page 14

... the digital display matches your desired pH control level. 3. Changing the ORP Setpoint The CAT 2000 is the level you wish to maintain a desired sanitizer level by the controller. 3. In order to meet Health Department standards for safe drinking water. Manually test pool or spa to confirm that the current sanitizer reading (chlorine, bromine, etc.) is preset from...
CAT 2000 - Page 15

...green "MANUAL" LED is illuminated. Automatic pH feeding will operate automatically in most applications, but should be disabled. About Proportional Feed The CAT 2000 features an advanced proportional feed algorithm which... with salt chlorine systems. Automatic ORP feeding will operate automatically in intervals based on the relationship between setpoint and actual water sample values.
CAT 2000 - Page 23

.... Setpoint adjustment is allowed only when this LED is outside of the pool or spa water (as calibrated) passing through the filtration system. Calibration of the various LED indicator lights on . pH Feed Indicator (#1) This green LED is illuminated whenever the pH chemical feeder is illuminated. pH Manual Off Indicator (#7) This red LED is illuminated when...
CAT 2000 - Page 24

... of the ORP channel of the controller normally indicates the current ORP (oxidation-reduction potential) of the pool or spa water passing through the filtration system. ORP Manual On Indicator (#15) This green LED is illuminated when pH feeding is manually disabled. ORP Automatic Control Indicator (#13) This green LED is illuminated when ORP...
CAT 2000 - Page 26

... manual. WATER MAINTENANCE Always test and record water chemistry readings in pool or spa water, the sensors may be clean and free from the flow cell. Clean the reference junction (the white teflon ring at the bottom of cleaning. Never allow a pH or ORP sensor to be performed using commercially available reference solutions. PRECISION CALIBRATION The CAT 2000 controller...
CAT 2000 - Page 28

...balance. Ensure that filtration system is functioning properly, flow is adequate, and water chemistry is properly installed and connected. SECTION 12. Check circuit breaker and/or... to functional grounding-type GFCI protected power source. 2. Ensure that sensor cables are observed. 1. Make sure "auto" pH feed mode is selected. 2. TROUBLESHOOTING Each CAT 2000 controller is ...
CAT 2000 - Page 29

...pH or ORP chemical feeder runs continuously. 1. Chlorine or bromine residual is selected. 2. Consider the effect of additional or alternative sanitizers will all electrical equipment in the maintenance section. pH or ORP readings... to the pool or spa. 2. Check to provide unstable readings after cleaning, replace sensors. 3. Check concentration of sanitizer or pH chemical. Ensure...
CAT 2000 - Page 31

...found to be directed to the following address: Hayward Commercial Pool Products 10101 Molecular Drive Suite 200 Rockville, MD 20850 (...to be defective upon examination. SECTION 14. Professional Series pH and ORP sensors are warranted for a period of five ... purchaser. WARRANTY LIMITED WARRANTY Hayward® warrants the CAT 2000 automated controller to be free of shipment from date ...

Similar Questions

Ph Readings Bounce Up And Down. Don't Stay Constant
We have a Cat 2000 controller installed for pool water balance control.We use liquid chlorine and Co...
(Posted by lemboet 2 years ago)
Orp Shutting Off
We have a CAT2000 why does the orp side shut off?? We come in and set it back to auto but the pool i...
(Posted by jaykessler119 2 years ago)
The Chl Side Of The Cat 2000 Not Sending Signal For Chlorine Pump To Function.
I have replaced the Stenner Chl Pump with a new one and checked the fuse.Fuse does not look blown.Wh...
(Posted by familyswim 7 years ago)
In Ground Pool Heater 150 Elect Ign
Heater circuit breaker will pop off when I place the switch on pool
(Posted by vrago 12 years ago)
Ask a New Question
Use the box below to post a new question about this Hayward product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Hayward Manuals

Find free Hayward CAT-2000 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Hayward Reviews

View thousands of Hayward user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Hayward customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Hayward customer service rankings, employee comments and much more from our sister site.

Hayward Recalls

Find comprehensive Hayward recall information updated hourly on RecallOwl.com.