Get support for Haier RDE350AW - 6.5 Cu. Ft. Electric Dryer

Haier RDE350AW Support Question

Haier RDE350AW Support Question

Find answers below for this question about Haier RDE350AW - 6.5 Cu. Ft. Electric Dryer.
Need a Haier RDE350AW manual? We have 1 online manual for this item!
Question posted by christiej04 on June 27th, 2012

Haier Model #rde350aw

NEED TO LOCATE THE HEATING ELEMENT. DRYER STOP DRYING. BUT EVERYTHING ELSE WORKS

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Haier RDE350AW Manual Pages

User Manual - Page 2

... 7 Gas Supply Requirements 9 Location of Your Dryer 10 Manufactured (Mobile) Home Instruction 11 Electrical Installation 12 3-Wire Cord Connections 13 4-Wire Cord Connections 14 Gas Connections 15 Replacement Parts 17 OPERATING INSTRUCTIONS 18-24 Understanding the Control Panel 18 Preparations before Drying 19 Load clothes into Dryer 20 Auto Dry Cycle 21 Timed Dry Cycle 22 Other...
User Manual - Page 3

... or to prevent property damage, personal injury or loss of the National Fuel Gas Code, ANSI Z223.1 or in Canada, CSA C22.1 Canadian Electrical Code Part 1. NOTE: The dryer is installed correctly and safely. Combustible materials, gasoline, and other flammable vapors and liquids must not be performed by a qualified or licensed contractor...
User Manual - Page 4

...electric shock, or injury to persons when using this appliance where it will be cleaned periodically by the manufacturers of the dryer. 14. Close supervision of the fabric softener or product. 11. Do not tamper with gasoline, dry... SAFETY INSTRUCTIONS WARNING - Do not use heat to dry articles or products to the weather. 7. Keep the dryer area clear and free from items that ...
User Manual - Page 5

.... Proper grounding must be ensured to your dryer. Use the dryer only for using our Haier product. Always disconnect dryer from electrical supply before it is properly grounded. 19. SAVE THESE INSTRUCTIONS DANGER Risk of electric shock and fire. Model number Serial number Date of flammable liquids and its intended purpose: drying clothes. 20. Thank you in the...
User Manual - Page 6

...inch open end 5 ELECTRICAL REQUIREMENTS Electric Dryer: (RDE350AW) Circuit Individual 30 Amp branch circuit fused with clothes dryers. Must be purchased to meet local electrical codes.) The dryer MUST employ a 3-...a specific type identified by a qualified installer. 2.Install the clothes dryer according to collapse, be discarded. Power Supply 3 or 4 wire, 120/240 Volt, 1 ...
User Manual - Page 7

Outlet Receptacle NEMA 10-30R receptacle should be located so the power supply cord is accessible when the dryer is in the installed position. (Canada - See Electrical Connections for more information on dryer) Dryers being installed in a manufactured (mobile) home MUST employ a 4-wire power supply cord NEMA 14-30 type SRDT or ST (as required) rated...
User Manual - Page 8

...increase drying times. 4. All male duct pipe fittings must not be exhausted into any gas vent, chimney, wall, ceiling or any concealed space of lint in operation. When the dryer stops,... the laundry area. Excessive lint can create a health and fire hazard. 3. The dryer must be expelled into the interior of air. 6. Explosion hazard: Do not install the dryer where gasoline...
User Manual - Page 9

...cause an increase in vent restriction. 3. of moist air from the drying compartment. 8 Only rigid or flexible metal duct work should be inspected and cleaned a minimum of every 12 months with... ft. 45 ft. 35 ft. Note: Exhausting refers to down drafts causing an increase in vent restriction. 5. In the United States, that the exhaust duct shall be used . 2. The more the dryer is...
User Manual - Page 10

...accessible for test gauge connection, MUST be constructed of the gas supply connection to the dryer. 6. The dryer MUST be disconnected from the gas supply piping system during any pressure testing of the...in accordance with the National Fuel Gas Code, ANSI Z223.1/NFPA 54. In the absence of the dryer in Canada, the current CAN/CGA B149.1 2. A 1/8 inch (0.32cm) N.P.T. English GAS SUPPLY ...
User Manual - Page 11

...bedroom, bathroom, alcove or closet MUST be solid with a solid door. 2. English LOCATION OF YOUR DRYER Do Not Install Your Dryer: 1. Installation in a closet with a maximum slope of the door and airfl...1inch (2.54 cm). No other fuel burning appliance shall be unobstructed. When installing the dryer in a closet with a door, a minimum of 120 square inches (774.2 square cm) of combustion...
User Manual - Page 12

... combustion. In Canada, the CSA Z240 is preferred. 2. Metal ducting must be not less than twice the area of the dryer exhaust outlet. 4. Rigid metal duct is applicable. 11 If dryer is exhausted through the floor and area beneath the manufactured home is enclosed, the exhaust system MUST terminate outside (outdoors, not...
User Manual - Page 13

... between copper and aluminum and can create electrical shock and/or fire hazard. This appliance must be purchased, allowing some slack in this manual for electric current. Locate the dryer within reach of malfunction or breakdown, grounding will have longer drying times than operation on the appliance. 1. ELECTRIC Dryer (RDE350AW) GROUNDING INSTRUCTIONS This appliance must be...
User Manual - Page 14

...cover and the strain relief mounting bracket located on the terminal block. approved strain relief into the power cord entry hole of the dryer with two screws. Tighten the strain relief...Amp. Tighten the screw securely. 5. English ELECTRICAL CONNECTIONS ELECTRIC Dryer (RDE350AW) 3-Wire Cord Connection (US models only) 1. Tighten the screws securing the cord restraint firmly against the power...
User Manual - Page 15

... 4 Conductor Cord Black 240V White Neutral Red 240V Green Ground 14 English ELECTRIC Dryer (RDE350AW) 4-Wire Cord Connections (US Models Only) Green Ground Screw Green Power Cord Ground Wire Brass Terminal Terminal Block... terminal block access cover and the strain relief mounting bracket located on the back of the mounting bracket . Remove the green neutral ground wire from the green ...
User Manual - Page 16

... green ground screw. 6. NEMA 14-30 type ST or SRDT through the louvered panel located on the back of the dryer. 2. Tighten the screws securing the cord restraint firmly against the power cord. ... relief. 5. Remove the shipping cap from gas supply line to the 3/8 inch (0.96cm) pipe located on the rear of liquified gases on , the safety switch will light, it is resting...
User Manual - Page 18

Make all packing materials inaccessible to death. WARNING The instructions in this dryer can not cover every possible condition and situation that may occur. Wiring ... destroy the carton and plastic bags after servicing. Check unit for US and Canada can be purchased through Haier America at 1-800-313-8495 Label all other literature included with . Children should not be allowed to use ...
User Manual - Page 19

.... To stop simply open the door and remove the clothes. 18 Push once to set drying temperatures. ...electric shock, or injury to persons, read all of the dry cycle the dryer will tumble periodically for 1 hour after the dry...dryer tub will automatically go in . Normal Normal drying Delicate Drying small quantity clothes and delicate fabric. Understanding the Control Panel Timed Dry...
User Manual - Page 25

... in the room, electric voltage, length of the dryer. t$MFBOUIFDBCJOFUXJUINJMETPBQBOEXBUFS%POPUVTFIBSTIPSBCSBTJWF cleaners, as this could damage the dryer. The filter can be washed or vacuumed. Remove the excess Lint Filter water from the filter by pulling on the tabs located on the inside...
User Manual - Page 27

...the date of original retail purchase, Haier will provide All Parts. Damage from state to you may have available the following information: Model number and serial number of your nearest... of original purchase. 90 days parts from incorrect electrical current, voltage or supply. Damage from date of the unit on authorized Haier dealer or service center. Adjustment of the problem...
User Manual - Page 52

...FTUPVWFSUF La sécheuse fonctionne mais ne sèche pas : t-FUBNCPVSFTUQFVUÐUSFUSPQQMFJO/FQBTSFNQMJSQMVTRVËNPJUJÏ t-FTUVZBVYEÏDIBQQFNFOUFUMFTDMBQFUTOFEPJWFOUQBTÐUSFPCTUSVÏT t-FUVZBVEÏDIBQQFNFOUEPJUÐUSFOFUUPZÏSÏHVMJÒSFNFOU...

Similar Questions

Heating Element On Haier Dryer 2.6 Cu.ft
My dryer does not blow warm enough. When I put it at the higher setting it does not blow any hotterD...
(Posted by mkgil 3 years ago)
How Do I Get Inside Of My Haier Dryer To Replace The Element Model #rde350aw
How do I get inside of my Haier dryer to replace the element.
(Posted by emmajackson476 10 years ago)
Haier Dryer Stopped Working
xqg6511su dryer stopped working all of a sudden. how to repair it?
(Posted by jamivaspecialty 11 years ago)
Ask a New Question
Use the box below to post a new question about this Haier product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Haier Manuals

Find free Haier RDE350AW - 6.5 Cu. Ft. Electric Dryer manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Haier Reviews

View thousands of Haier user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Haier customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Haier customer service rankings, employee comments and much more from our sister site.

Haier Recalls

Find comprehensive Haier recall information updated hourly on RecallOwl.com.