Get support for Haier HSU18VH7-W - Ductless Split Outdoor Unit Heat Pump

Haier HSU18VH7-W Support Question

Haier HSU18VH7-W Support Question

Find answers below for this question about Haier HSU18VH7-W - Ductless Split Outdoor Unit Heat Pump.
Need a Haier HSU18VH7-W manual? We have 1 online manual for this item!
Question posted by engphys57 on May 26th, 2012

Hsu18vck Compressor

What type of compressor is it? Recip, rotary, scroll or what?

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Haier HSU18VH7-W Manual Pages

Service Manual - Page 1

THIS MANUAL IS USED BY QUALIFIED APPLIANCE TECHNICIANS ONLY. HSU18VH7 Air conditioner Edition: 10070808 Domestic Air conditioner CAUTION READ THIS MANUAL CAREFULLY TO DIAGNOSE TROUBLE CORRECTLY BEFORE OFFERING SERVICE. HAIER DOES NOT ASSUME ANY RESPONSIBILITY FOR PROPERTY DAMAGE OR PERSONAL INJURY FOR IMPROPER SERVICE PROCEDURES DONE BY ONE UNQUALIFIED PERSON.
Service Manual - Page 2

Air conditioner Edition: 10070808 CONTENTS 1. COMPRESSOR PERFORMANCE DIAGRAM 24 9. INSTALLA TION 12 6. SPECIFICATION 3 3. SCHEMATIC DIAGRAM OF PCB 25 WIRING DIAGRAM 20 7. TROUBLE SHOOTING 10 5. ELECTRICAL CONTROLS 4 4. THERMISTOR RESISTANCE CHART 22 8. GENERAL INFORMATION 1 2.
Service Manual - Page 3

...or death due to be used as the compressor and fan motor are NOT to comply with the use by authorized services who troubleshoot and repair these units. It is to troubleshoot and repair electrical,...color coding for ground wires is intended for use of the air conditioner. It is assumed that users of heat exposure, which may result in this manual are familiar with safety information...
Service Manual - Page 4

HSU18VH7 10070808 Product Features TEMP SIGNAL SENDING FAN SPEED SLEEP HEALTH POWER ON/OFF 18000/17800 BTU 1580/1560W/7/7.5A SEER:13.0/13.0 HSPF:7.7/7.7 18000/18000 BTU 1520/1480W/6.7/7.2A 500 CFM 1PH 230/208V ~ 60Hz
Service Manual - Page 7

... at the stand-by time of 3 minutes (State 2) 3.2.3.3 Tr Tr Ts+2℃, compressor, outdoor fan run continuously, indoor fan runs as per setting wind speed (State 1); 3.2.3.2 Ts+2℃≥ Tr≥Ts, compressor, outdoor fan run according to air conditioners of indoor coil pipe a. Air conditioner Edition: 10070808 3.2 . Tr≥23℃ b. Tr in fixed lower wind speed...
Service Manual - Page 8

... begins, applicable to fan-coil model) Under heating state, the compressor will cease; After the state of indoor coil pipe is ≥ 23℃, start (preventing cold wind when heating running begins, indoor fan will conduct the following fan control: If the temperature of Tp-Tr Air conditioner Edition: 10070808 State1 State3 State2 Ts-1 Ts...
Service Manual - Page 9

... of return deference Compressor,outdoor fan OFF after 5 minutes Fan,compressor ON 0 7 Tp(℃.) 3.2.8 3 minutes stand-by time When the compressor ceases due to the sensor OFF, unit On or OFF or fault, it will maintain pause for 3 minutes. 3.2.9 Overload protection during heating running Temperature protection of indoor coil pipe: Under heating state, the air conditioner will restart...
Service Manual - Page 10

The rules of click from the buzzer, then the air conditioner will turn to the trial run state. The unit will run in the refrigerating mode and the indoor fan will...of function: Pressing the SLEEP button on the remote control unit for 10 times until hearing 2 sounds from the buzzer on the panel. 3.2.11 Trial run function When the air conditioner is in OFF state, press the emergency switch for ...
Service Manual - Page 11

MODEL HSU18VH7 PCB 0010403861 The SW2 select"25"OR "35" 25 - 9- Air conditioner Edition: 10070808 running for 1 hour under heating mode, the setting temperature will decrease 2℃, after another 1 hour, it will decrease the 2℃ again, and after 3 hours, it will increase 1℃, and after other 3 hours, it will cease.
Service Manual - Page 13

... the indoor mainboard about 1-6.5v NO the PCB of the indoor unit is damaged and needs replacing YES the motor of the indoor unit is damaged and needs replacing. - 11- see the following flow... Electrify the machine again and turn it on the indoor mainboard and reinsert them. Air conditioner Edition: 10070808 Table for Wrong Codes Wrong express power timing operating reasons Ways and means...
Service Manual - Page 18

Power Cable:AWG12X3. 16 Indoor unit 10070808 Grounding line Grounding line Power supply Power supply Connecting wiring:AWG12X5. Power Cable:AWG12X3. Connecting wiring:AWG12X4+AWG18X2.
Service Manual - Page 22

10070808 WIRING DIAGRAM INDOOR UNIT WIRING DIAGRAM OF INDOOR UNIT ION GENERATOR FAN MOTOR M LOUVER MOTOR M CN4 COMP N L CN1 CN2 SW1 CN3 CN7 CN8 CN9 PCB CN10 CN12 NOTING: 1 ONLY COOLING TYPE DOESN'T HAVE THE DOTTED LINE. 2 THE DASHED UNIT IS OPTIONAL UNIT. 1 2 3 45 wwwww TO OUTDOOR UNIT REV R:RED W:WHITE B:BLACK BL:BLUE BR:BROWN 20
Service Manual - Page 23

OUTDOOR UNIT Edition:10070808 WIRING DIAGRAM OF OUTDOOR UNIT 0010510468 B B RR ~ SCM C W W R B R BR ~M w B B W 1 234 5 67 GG TO INDOOR UNIT L2(N) L1(L) Grounding line Y/G:YELLOW/GREEN R:RED BL:BLUE Y:YELLOW B:BLACK BR:BROWN W:WHITE Note: Because of the difference of compressor, the dotted line part may not exist. 21

Similar Questions

Dear Sirs, The Fan Of The Outdoor Unit Doesn't Work During Heating Regime.
When the device is in heating regime, the fan of the outside unit doesn't work. When I push a little...
(Posted by svgeorgy 10 years ago)
How Can I Tell If The 2 Units I Have Are A/c Units Or Heat Pumps?
A repairman who inspected one of the units says it has "a reversible heat pump" inside that a/c unit...
(Posted by avicaryn 10 years ago)
I Have A Hc30a1var Outdoor Unit I Need The Rating Numbers For The Capacitor
I ahve a HC30A1var outdoor unit, I need the rating numbers for the compressor capacitor
(Posted by tbuster 11 years ago)
Holding Contacts Will Not Stay Closed. Green Flashing Light On Outdoor Unit.pa
HOLDING CONTACTS WILL NOT STAY CLOSED, HAVE GREEN FLASHING LIGHT ON OUTDOOR UNIT CONTROL PANEL
(Posted by JOHNALBANO 12 years ago)
Haier Ductless Split Heat Pump
is reversing valve energized in heat or cool
(Posted by chuckdifr 13 years ago)
Ask a New Question
Use the box below to post a new question about this Haier product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Haier Manuals

Find free Haier HSU18VH7-W - Ductless Split Outdoor Unit Heat Pump manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Haier Reviews

View thousands of Haier user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Haier customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Haier customer service rankings, employee comments and much more from our sister site.

Haier Recalls