Question posted by Anonymous-67297 on July 19th, 2012

Does Anyone Have A Picture Of Capacitor Wiring. Trying To Replace Capacitor

The person who posted this question about this Haier product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Haier HC36A1VAS Manual Pages

User Manual - Page 1

Installation & Operation Manual Central Air Conditioner 10 to 13 SEER 1.5 to 5 Tons Models: HC18-60A1VAR/S HC18-60C1VAR HC18-60D1VAR No.0010572324 K The information contained in this booklet is subject to change without notice.
User Manual - Page 2

...Failure to follow these regulations may harm the environment and can lead to the air conditioner caused by the attachment or use of substantial fines. Failure to follow these...If the service panel is not attached securely, it could result in accordance with the air conditioner. The United States Environmental Protection Agency (EPA) has issued various regulations regarding the ...
User Manual - Page 3

...; R: Heat pump. 24 Nominal capacity in unsatisfactory operation or dangerous conditions. C: Air conditioner; General 5 6.2.Unit clearances 6 6.3.Refrigerant piping 6 6.4.Electrical wiring 10 7.System Startup 11 8.Operation 12 9.Miscellaneous 12 9.1.Replacement parts 12 9.2.Troubleshooting guide 12 9.3.Wiring diagram 12 1.INTRODUCTION This manual contains the installation and operating...
User Manual - Page 4

...] [632* 632*919] [632* 632*919] [832*832*930] [ 832*832*930] [832*832*1030] Net Weight - Table 1: Model:HC18-60A1VAR/S 2 MODEL: HC18A1VAR HC24A1VAR HC30A1VAR HC36A1VAS HC42A1VAR HC48A1VAR HC60A1VAR Unit Supply Voltage 208/230-1-60 Normal Voltage Range Compressor Brand Minimum Circuit Amps 10.1 Max Fuse or Max CKT. Lbs (kg...
User Manual - Page 5

...52] 3/8"[9.52] Vapor Line OD - D W H Table 2:System Cooling Capacity Figure 1 Outdoor Unit With This Indoor Air handler Model Number Air Handler Compressor Cooling Capacity (Btu/h) SEER Rated HC18A1VAR HC24A1VAR HC30A1VAR HC36A1VAS HC42A1VAR HB2400VA1M20 HB2400VA1M20 HB3000VA1M20 HB3600VA1M20 HB4200VA1M25 brand Bristol Bristol Bristol Bristol Sanyo Sensible 13000 17000 20000...
User Manual - Page 6

...[113] 262[119] 282[128] Table 6:System Cooling Capacity Outdoor Unit Model Number HC18D1VAR HC24D1VAR HC30D1VAR HC36D1VAR HC42D1VAR HC48D1VAR HC60D1VAR With This Indoor Air handler Air Handler Compressor Cooling Capacity (Btu/h) brand Sensible Total HB2400VD1M20 Bristol 13300 18000 HB2400VD1M20 Bristol 17700 24000 HB3600VD1M22 Bristol 20669 28000 HB3600VD1M22 Bristol 25900...
User Manual - Page 7

... unit life. In coastal areas, locate the unit on a slab or rooftop. Disconnect all electrical power to the equipment location and exposure. Power supply and wiring. WARNING - Regular cleaning and waxing of supporting members. A good liquid cleaner may be used several times a year to remove matter that will not wash off...
User Manual - Page 8

... or wiring. For service access to the weather-tight integrity of noise or vibration, slab should be connected to avoid lawn mower discharge toward the unit depositing debris on all air inlet ...should not be placed between the condenser and the slab. This application minimizes exposed tubing and wiring, minimizing the space for the unit are to be located under an overhang, there should...
User Manual - Page 9

... contact the tubing. Do not kink or twist the tubing. Generally 3/8" wall thickness of Armflex or equivalent is used . Apply the line insulation by surrounding air. kitchen, boiler rooms, hot attics & rooftop surface), then, they are to and during installation. OUTDOOR UNIT INVERTED LOOP LIQUID LINE OUTDOOR UNIT OUTDOOR UNIT PITCH...
User Manual - Page 11

... microns or less for brazing. 8.Pressurize the lines to the vacuum pump and stop valves at the connecting ends. Evacuate the lines and indoor coil. Air in the valve, if removed for a minimum of 30 minutes. Reinstall the Schrader core in a system causes high condensing pressure, which increases power consumption and...
User Manual - Page 12

.... 85 5.Refer to the Section 7 - Table 8:System charging table by superheat 6.4.ELECTRICAL WIRING ! WARNING - Incomplete connection or fixing of the power circuit is insufficient or there is incomplete...due to this instruction). Run system at least 10 minutes to allo System Superheat Ambient Return Air Temperature ( F) Temperature At 65 70 75 80 85 Condenser Inlet ( F) 60 17 25...
User Manual - Page 13

... running correctly? 6.Check the refrigerant charge (see Instructions under "Charging the System"). 7.Replace service port caps. Turn system switch to "COOL" and turn on power supply at disconnect switch. 2.Turn temperature setting as high as shown on the wiring diagram. 7.SYSTEM STARTUP 1.Turn thermostat to "ON". Be sure it will leak if...
User Manual - Page 14

...Wiring Diagram Refer to the appropriate wiring diagram included in personal injury or death. 12 NOTE: There may cause the compressor to reset. Make sure overload has had time to the unit before condemning the compressor. 9.MISCELLANEOUS 9.1. WARNING - Disconnect power to shut off for a complete parts list. 9.2. Replacement... up to cycle unit without start relay or start capacitor.
User Manual - Page 15

...Low vapor - Add start capacitor defective Loose connection Condenser fan runs, Compressor stuck, grounded or open compressor doesn't motor winding, open . Replace - Blocked outdoor coil Clear ...Blocked outdoor coil High head - Interconnecting low voltage wiring damage Replace thermostat wiring Dirty filters Clean & replace Indoor air blockage Check supply registers and return grills for ...
User Manual - Page 16

...ithout optional electr ic heater ki t. AND LOCAL CODES AS APPLICAB LE. REPLACEMENT WIRE MUST BE THE SAME GAGE AND INSULATION TYPE AS ORIGINAL WIRE. RUN CAPACITOR BLOWER MOTOR CC - INDOOR BLO WER MOTOR OFM - RED VI -... SW-2 1) Confi rm sy stem selec tion. GRAY BR - HC18-60A1VAR/S HC18-60C1VAR HC18-60D1VAR Air Conditioner Wi ri ng Diagram 5 YL 6C S R RD BK RD OFM 6 M BR R S BR...

Similar Questions

Air Conditioner Wont Turn On. It Worked Just Fine Two Days Ago
I have a Haeir air conditioner HPAC9M two days ago it worked fine but now it wont turn on
(Posted by alexisiam 3 years ago)
Refrigerant Type For Hc36a1vas
What type of refrigerant does the HC36A1VAS use
(Posted by Mamasalem 4 years ago)
Portable Air Conditioner Keeps Shutting Off
my portable air conditioner keeps shutting down after running for about 10 min
(Posted by Buttercup2 6 years ago)
Haier Esa412r Air Conditioner Bd Noise Rating
what is the db noise rating for the haier esa412r window air conditioner ar various fan speeds
(Posted by Wfrooney 7 years ago)
My Air Conditioner Go Off
when the air conditioner is funtion for only little time like 20 minute is going to signal the STOP ...
(Posted by haydeejose 7 years ago)
Ask a New Question
Use the box below to post a new question about this Haier product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Haier Manuals

Find free Haier HC36A1VAS manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Haier Reviews

View thousands of Haier user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Haier customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Haier customer service rankings, employee comments and much more from our sister site.

Haier Recalls

Find comprehensive Haier recall information updated hourly on RecallOwl.com.