Haier HC30D1VAR Support Question

Haier HC30D1VAR Support Question

Find answers below for this question about Haier HC30D1VAR.
Need a Haier HC30D1VAR manual? We have 1 online manual for this item!
Question posted by AHamby on August 11th, 2011

What Size Capacitor Is Needed For The Compressor

The person who posted this question about this Haier product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Haier HC30D1VAR Manual Pages

User Manual - Page 1

Installation & Operation Manual Central Air Conditioner 10 to 13 SEER 1.5 to 5 Tons Models: HC18-60A1VAR/S HC18-60C1VAR HC18-60D1VAR No.0010572324 K The information contained in this booklet is subject to change without notice.
User Manual - Page 2

...Protection Agency (EPA) has issued various regulations regarding the introduction and disposal of the air conditioner and may result in improper installation, adjustment, service or maintenance possibly resulting in ... in violation of new laws we suggest that any damage or defect to the air conditioner caused by the attachment or use of any responsibility for equipment installed in a ...
User Manual - Page 3

C: Air conditioner; Give this manual and any instructions packaged with separate equipment required to make up the system prior to the owner and explain its provisions. C=208/230-3-60, D=460-3-60, Y=575-3-60 A Body style R Compressor type Example: HC24A1VAR 1 A=10, B=11, C=12, D=13, E=14 1 Design series. 1 - 1st Generation V Electric: V=208/230-1-60; Carefully read...
User Manual - Page 4

...40 35 45 50 60 50 Rated Load Amps 7.4 9.6 11.8 14.4 18.3 15.8 21.3 24.4 26.9 28.9 22.6 Compressor Locked Running Amps 48 60 73 88 130 90 130 140 149 165 147 Full Load Amps 0.86 0.86 1.4 1.4 1.43 1.... HC30A1VAR HC36A1VAS HC42A1VAR HC48A1VAR HC60A1VAR Unit Supply Voltage 208/230-1-60 Normal Voltage Range Compressor Brand Minimum Circuit Amps 10.1 Max Fuse or Max CKT.
User Manual - Page 5

... Minimum Circuit Amps 10.1 13.4 16.2 Max Fuse or Max CKT. D W H Table 2:System Cooling Capacity Figure 1 Outdoor Unit With This Indoor Air handler Model Number Air Handler Compressor Cooling Capacity (Btu/h) SEER Rated HC18A1VAR HC24A1VAR HC30A1VAR HC36A1VAS HC42A1VAR HB2400VA1M20 HB2400VA1M20 HB3000VA1M20 HB3600VA1M20 HB4200VA1M25 brand Bristol Bristol Bristol Bristol Sanyo...
User Manual - Page 6

... 220[100] 249 [113] 262[119] 282[128] Table 6:System Cooling Capacity Outdoor Unit Model Number HC18D1VAR HC24D1VAR HC30D1VAR HC36D1VAR HC42D1VAR HC48D1VAR HC60D1VAR With This Indoor Air handler Air Handler Compressor Cooling Capacity (Btu/h) brand Sensible Total HB2400VD1M20 Bristol 13300 18000 HB2400VD1M20 Bristol 17700 24000 HB3600VD1M22 Bristol 20669 28000 HB3600VD1M22...
User Manual - Page 8

..., owners should be advised to the weather-tight integrity of the unit. Condenser air enters from the overhang. Provide a level concrete slab. A good material to the compressor and control box, allow 18" minimum clearance. Note the following guidelines: 6 Air discharges upward from back wall with subsequent damage to building structure. The most common...
User Manual - Page 9

...high ambient temperatures (i.e. Liquid line does not necessarily need insulation, however, if they should a leak be ... Make sure to use the proper size tubing for every 10' of Armflex or... Apply the line insulation by surrounding air. SU LIQUID LINE CTION LINE OIL ... to pitch the horizontal suction line toward the compressor, approximately 1/2" for the liquid line to prevent...
User Manual - Page 10

...the suction and liquid line fittings, as there is sufficient for any combination of the unit size and the maximum refrigerant line length. To ensure good oil return to remove pressure. !...follow: 8 Per foot 5/16" Line +/- 0.4 oz. Instructions on the liquid line to the compressor when the indoor unit is below the outdoor unit (Figure 3-A), and 50' when the indoor unit is in Figure...
User Manual - Page 11

... vacuum pump and wait 15 minutes. Close the valve to the atmosphere! If the refrigerant needs to be removed from the service port to the vacuum pump and stop valves at the ... minimum of federal law to correct the charge inside, always use a recovery or recycling device. ! Air in a system can render it stops. WARNING - Reinstall the Schrader core in a very short time...
User Manual - Page 12

Run system at least 10 minutes to allo System Superheat Ambient Return Air Temperature ( F) Temperature At 65 70 75 80 85 Condenser Inlet ( F)... line near condensing unit. Do not connect the ground to the Section 7 - "System Startup"). Note: Some states need the power supply wiring within special tybe be installed to one AC outlet. Add 90 charge to defective contact, defective ...
User Manual - Page 13

...Volt minimum, 25 VA service from the indoor transformer as shown on the minimum copper wire size as it is running in cooling mode. 5.Check to see Instructions under "Charging the System... Wire Length - Service port cores are running correctly? 6.Check the refrigerant charge (see if compressor and outdoor fan are for tubing and sheet metal rattles. 9.Instruct the owner on operation and...
User Manual - Page 14

... should be more than one electrical disconnect switch. NOTE: There may cause the compressor to both the indoor and outdoor units. Under some conditions, it can cause ... to cycle unit without start relay or start capacitor. 8.OPERATION Most single phase units are operated without waiting 5 minutes. The compressor has an internal overload protector. Replacement Parts Contact...
User Manual - Page 15

...reduce restriction - Add start capacitor defective Loose connection Condenser fan runs, Compressor stuck, grounded or open compressor doesn't motor winding, open . replace air filter Add low ambient ...High Flowrator piston size too large vapor pressures Defective compressor valves Incorrect capillary tubes Low vapor - check for overload to correct size piston Replace compressor Replace coil ...
User Manual - Page 16

HC18-60A1VAR/S HC18-60C1VAR HC18-60D1VAR Air Conditioner Wi ri ng Diagram 5 YL 6C S R RD BK RD OFM 6 M .... REPLACEMENT WIRE MUST BE THE SAME GAGE AND INSULATION TYPE AS ORIGINAL WIRE. COMPRESSOR HPS - LOW PRESSURE SWITCH IBM - START THERMISTOR (OPTIONAL) TRAN - BROWN GR- VIOLET WH - RUN CAPACITOR BLOWER MOTOR CC - CRANKCAS E HEATER SWITCH (OPTIONAL) CMPR - REVERSING VALVE ...

Similar Questions

Cooling Problem With My Haier Air Conditioner Model # Hpyo8xcm-e .
my air conditioner does emit cool ( cold ) air BUT it doesn't evenly cool my room ( it's a medium to...
(Posted by leealvarez2 3 years ago)
Air Conditioner Wont Turn On. It Worked Just Fine Two Days Ago
I have a Haeir air conditioner HPAC9M two days ago it worked fine but now it wont turn on
(Posted by alexisiam 3 years ago)
Portable Air Conditioner Keeps Shutting Off
my portable air conditioner keeps shutting down after running for about 10 min
(Posted by Buttercup2 6 years ago)
My Air Conditioner Go Off
when the air conditioner is funtion for only little time like 20 minute is going to signal the STOP ...
(Posted by haydeejose 7 years ago)
. Changing Capacitor. Wire The Two Red Wires And One Yellow To Proper Termina
I forgot to take picture of old capacitor and now have two terminal MAR 12743 capacitor and need to ...
(Posted by gdalec 9 years ago)
Ask a New Question
Use the box below to post a new question about this Haier product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Haier Manuals

Find free Haier HC30D1VAR manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Haier Reviews

View thousands of Haier user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Haier customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Haier customer service rankings, employee comments and much more from our sister site.

Haier Recalls

Find comprehensive Haier recall information updated hourly on RecallOwl.com.