Question posted by Tomashbyac on February 4th, 2014

What Refrigerant Did This System Run On(hbu-42c03/r1)

The person who posted this question about this Haier product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Haier HBU-42CH03 Manual Pages

User Manual - Page 1

Please keep this manual carefully. ROOM AIR CONDITIONER OUTDOOR UNIT INSTALLATION INSTRUCTIONS CONTENTS Name of Parts 1 Safety Cautions 2-3 Installation Procedure---------4-13 HBU-28CH03 HBU-28HH03 HBU-42CH03 HBU-42CI03 HBU-42HI03 No.0150500832 Before using the air conditioner,please read this manual properly for future use.
User Manual - Page 3

... the following important Safety Cautions. Incorrect operations may fall down and cause accidents. If the conditioner is found (e. In such case, to conform with the following information in severe consequences of... Cautions should be at hand so that they can ensure the correct operation of air-conditioner the base should be checked for any abnormal phenomena is transferred to the new ...
User Manual - Page 4

... installed in case of goods and people may cause faults or fire accidents. Incorrect pipe use correctly-typed fuse. Air-conditioner can't be connected to prevent the refrigerant from leaking. Earthing wire should be sure to take measures to the gas pipe, water pipe, lightning rod or phone line, incorrect earthing may cause...
User Manual - Page 5

... Installation of installation satisfying the following conditions and, at four sides are not suitable for installation. Place where obstacles do not exist near the air inlet and air outlet . Edging 2. Place free from heat radiation from the unit top (4).Don't block the surroundings of the unit must NOT be discharged. Mount guide...
User Manual - Page 6

...: (1) Place the concrete foundation deep enough. Installation Procedure Installation of outdoor unit 862 Power Wiring Terminal 730 Power Wiring Distribution Hole 25 310 340 635 HBU-28CH03 HBU-28HH03 5 Installation of outdoor unit (1) Installation Fix the unit in a proper way according to the condition of a place where it is installed by referring...
User Manual - Page 7

Installation Procedure Installation of outdoor unit HBU-42CH03 1008 Power Wiring Terminal Power Wiring Distribution Hole 830 25 646 447 410 6
User Manual - Page 8

Installation Procedure HBU-42CI03 HBU-42HI03 948 Installation of outdoor unit 1250 25 580 340 380 4. Refrigerant piping Flare connection Gas pipe Indoor unit Liquid pipe stop valve Outdoor unit stop valve HBU-42CH03 HBU-42CI03 HBU-42HI03 HBU-28CH03 HBU-28HH03 7
User Manual - Page 9

... careful not to be connected, then flare the pipes. (3) Limitations for one way piping length and vertical height difference. Installation Procedure (2) Piping size Refrigerant piping HBU-28CH03 HBU-28HH03 HBU-42CH03 HBU-42CI03 HBU-42HI03 Liquid pipe Gas pipe Liquid pipe Gas pipe 9.52x0.8mm 15.88x1.0mm 9.52x0.8mm 19.05x1.0mm 90+0.5 Install the removed...
User Manual - Page 10

Air discharging method After finishing connection of outdoor unit, tighten the valve rod before giving pressure (both gas and liquid valve rods). Third step: 3.0 MPa (30kg/cm2g) pressurize about 24 hours. It shall be found . methods to the pipe connection mode as the following figure shown. Installation Procedure Refrigerant... the circulation system of refrigerant pipe, it again or...
User Manual - Page 11

...the vacuum pump of the connecting pipe, generally is : Refrigerant charging amount = (L-5) x M (g) For HBU-28CH03,HBU-28HH03, HBU-42CH03, HBU-42CI03,HBU-42HI03 M=65 Only in COOLING operation can be confirmed both... it is unnecessary to remove the air inside the system. Be carefull when charging refrigerant, do not let the air mix into refrigerant pump to perform vacuumizing. Low pressure ...
User Manual - Page 12

... breaker Power source Earth leakage breaker Model Phase Switch breaker Overcurrent protector wire size Switch Leak (A) rated capacity (A) (minimum) breaker current HBU-42CH03 HBU-42CI03 HBU-42HI03 3 30 20 2.5mm2 30 30mA HBU-28CH03 HBU-28HH03 1 40 36 4.0mm2 40 30mA (2) Wiring connection Make wiring to supply power to the terminal block. GROUND CONNECTIONS MUST BE...
User Manual - Page 13

Installation Procedure Electric wiring Y/G W B R Y/G W B Y/G 1 2 3 L N To Indoor Unit POWER SUPPLY: 1PH,220-230V~,50Hz FIG.1 HBU-28CH03 Y/G W B Y/G L N Y/G W B R BR GR Y/G 1 2 3 4 5 POWER SUPPLY: 1PH,220-230V~,50Hz To Indoor Unit FIG.2 HBU-28HH03 Y/G Y/G R S TN 1 2 3 POWER SUPPLY: To Indoor Unit 3N~,380-400V,50Hz FIG.3 HBU-42CI03 HBU-42CH03 HBU-42HI03 12
User Manual - Page 14

...air for gas pipe. Suction pressure at check joint on the side before taking off the front panel toward the direction shown in figure. 2) Connect wires to energize the crankcase heater in a proper way and penetrate the wires through the opening for about 30 minutes, and check the following. Test run Run...power stoppage. (1) Before starting test run (for Heat pump models) Confirm whether...

Similar Questions

Commercial Cool Air Conditioner Model# Cwh12a
Where can I purchase a new Commercial Cool air conditioner from?
(Posted by williamsshannon984 2 years ago)
Air Conditioner Wont Turn On. It Worked Just Fine Two Days Ago
I have a Haeir air conditioner HPAC9M two days ago it worked fine but now it wont turn on
(Posted by alexisiam 3 years ago)
Portable Air Conditioner Keeps Shutting Off
my portable air conditioner keeps shutting down after running for about 10 min
(Posted by Buttercup2 6 years ago)
Haier Esa412r Air Conditioner Bd Noise Rating
what is the db noise rating for the haier esa412r window air conditioner ar various fan speeds
(Posted by Wfrooney 7 years ago)
My Air Conditioner Go Off
when the air conditioner is funtion for only little time like 20 minute is going to signal the STOP ...
(Posted by haydeejose 7 years ago)
Ask a New Question
Use the box below to post a new question about this Haier product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Haier Manuals

Find free Haier HBU-42CH03 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Haier Reviews

View thousands of Haier user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Haier customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Haier customer service rankings, employee comments and much more from our sister site.

Haier Recalls

Find comprehensive Haier recall information updated hourly on RecallOwl.com.