Get support for Haier AU48NAIEAA

Haier AU48NAIEAA Support Question

Haier AU48NAIEAA Support Question

Find answers below for this question about Haier AU48NAIEAA.
Need a Haier AU48NAIEAA manual? We have 1 online manual for this item!
Question posted by BOND123 on August 13th, 2014

Haier Au48naieaa Manual How Wark..i Have Many Problems..all Make Stand Bay

The person who posted this question about this Haier product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

Answer #1: Posted by TommyKervz on August 13th, 2014 5:23 AM
TommyKervz

Member since:
January 10th, 2013

Points: 17,776,823
100
points
Download the user guide on the link
http://www.helpowl.com/manuals/Haier/AU48NAIEAA/97954


Hope that is helpful.
Kervz at www.satechhelp.co.za

Related Haier AU48NAIEAA Manual Pages

User Manual - Page 1

ROOM AIR CONDITIONER OUTDOOR UNIT INSTALLATION INSTRUCTIONS AU182AEEAA CONTENTS Name of Parts 1 Safety Cautions 2-3 Installation Procedure---------4-13 AU242AGEAA AU282AGEAA AU28NAGEAA AU36NAHEAA AU362AHEAA AU48NAIEAA AU60NAIEAA No.0010577959 B Before using the air conditioner,please read this manual properly for future use. Please keep this manual carefully.
User Manual - Page 3

.... The Safety Cautions should be checked at hand so that they can ensure the correct operation of air-conditioner the base should be checked for any abnormal phenomena is transferred to the new user, this manual should be as well transferred to conform with the following information in injuries or machine damages; g.smell...
User Manual - Page 4

... respon- Connect earthing wire. Incorrect pipe use may cause water leak, electrical shock and fire hazard. Don't operate the air-conditioner with inflammable gases because the inflammable gases near to placed on or stand on outdoor unit. Call the dealer to take every measure in a small room be shocked. Safety Cautions WARNING! It...
User Manual - Page 5

... a strong wind. Place surrounded at the same time, obtain a consent from an opening edge. Accessories "Edging" for the unit. Install the unit so that the air outlet section of electric wires from the client or user. Edging 2. Place free from heat radiation from the unit top (4).Don't block the surroundings of...
User Manual - Page 6

... (b) Foundation anchor Unit Unit Anchor bolt Concrete foundation To fix by bolts AU36NAHEAA AU362AHEAA (a) Concrete foundation Anchor bolt Unit Concrete foundation To fix by bolts AU48NAIEAA AU60NAIEAA (a) Concrete foundation Concrete foundation Anchor bolt (b) Foundation anchor Unit Concrete foundation Anchor bolt (b) Foundation anchor Unit Anchor bolt Unit Concrete foundation To fix by...
User Manual - Page 8

... piping AU182AEEAA Flare connection Indoor unit Gas pipe 3-way stop valve Liquid pipe Flare connection Outdoor unit 2-way stop valve AU242AGEAA AU282AGEAA AU28NAGEAA AU36NAHEAA AU362AHEAA AU48NAIEAA AU60NAIEAA Flare connection Gas pipe 3-way stop valve Indoor unit Liquid pipe Flare connection Outdoor unit 3-way stop valve 7 Installation Procedure ...
User Manual - Page 9

...Procedure Refrigerant piping (2) Piping size AU182AEEAA AU242AGEAA AU282AGEAA AU28NAGEAA AU36NAHEAA AU362AHEAA AU48NAIEAA AU60NAIEAA Liquid pipe Gas pipe Liquid pipe Gas pipe Liquid pipe Gas...difference. Be careful not to Fig. Model AU182AEEAA AU242AGEAA AU282AGEAA AU28NAGEAA AU36NAHEAA AU362AHEAA AU48NAIEAA AU60NAIEAA One way piping length less than 20 m Vertical height difference (between ...
User Manual - Page 10

...pressure (both gas and liquid valve rods). After confirming the leaking point, welding it shall perform air tightness test. The gas and liquid valve are all in each 1* difference of refrigerant pipe, ...The pressure does not drop-passed The pressure drops-check the leaking point. Little leakage will make 0.01MPa(0.1kg/cm2g) pressure change. In order to the pipe connection mode as the ...
User Manual - Page 11

... = (L-5) x M (g) For AU182AEEAA, M=30 For AU242AGEAA, AU282AGEAA, AU28NAGEAA, AU36NAHEAA, AU362AHEAA, AU48NAIEAA, AU60NAIEAA, M=65 Only in COOLING operation can be vacuumized for other 1 hour. Low pressure peizometer...Charging amount of refrigerant When the total length (L) of low pressure vavle. After air tightness test and discharging all the nitrogen, connect the vacuum pump as the following...
User Manual - Page 12

...AU48NAIEAA AU60NAIEAA 3 30 26 4.0 40 30 26 6.0 40 30 20 2.5 30 30 20 4.0 30 30 (2) Wiring connection Make wiring to supply power to the terminal block. The breaker of the air conditioner... and instruction manual. 11 and the distance between its service agent or a similar qualified person. GROUND CONNECTIONS MUST BE COMPLETED BEFORE MAKING LINE VOLTAGE ...
User Manual - Page 13

... 1 2 3 TERMINAL BLOCK Y/G FIG.1 For :, AU242AGEAA, AU282AGEAA, AU362AHEAA To Indoor Unit Y/G L N 12 3 POWER SUPPLY: 1PH, 220-230V~, 50Hz OUTDOOR UNIT TERMINAL BLOCK FIG.2 For: AU28NAGEAA, AU36NAHEAA, AU48NAIEAA, AU60NAIEAA To Indoor Unit R S TN 1 2 3 Y/G OUTDOOR UNIT TERMINAL BLOCK POWER SUPPLY: 380-400V, 3N~, 50Hz FIG.3 WARNING DO NOT CONNECT THE NEUTRAL WIRE N TO R , S OR...
User Manual - Page 14

... Run the unit continuously for indoor unit. Suction pressure at check joint on for over 12 hrs to the EMC testing. Temperature difference between return air and supply air for about 30 minutes, and check the following consults are not expected. (In case of a lamp ).
User Manual - Page 15

Address: Haier Garden, Qianwangang Road, Economic Development Zone, Qingdao, Shandong 266500, P.R.China Web Site: http://www.haier.com HAIER GROUP Qingdao Haier Air Conditioner Electric Co., Ltd.

Similar Questions

Commercial Cool Air Conditioner Model# Cwh12a
Where can I purchase a new Commercial Cool air conditioner from?
(Posted by williamsshannon984 2 years ago)
Cooling Problem With My Haier Air Conditioner Model # Hpyo8xcm-e .
my air conditioner does emit cool ( cold ) air BUT it doesn't evenly cool my room ( it's a medium to...
(Posted by leealvarez2 3 years ago)
Portable Air Conditioner Keeps Shutting Off
my portable air conditioner keeps shutting down after running for about 10 min
(Posted by Buttercup2 6 years ago)
Haier Esa412r Air Conditioner Bd Noise Rating
what is the db noise rating for the haier esa412r window air conditioner ar various fan speeds
(Posted by Wfrooney 7 years ago)
My Air Conditioner Go Off
when the air conditioner is funtion for only little time like 20 minute is going to signal the STOP ...
(Posted by haydeejose 7 years ago)
Ask a New Question
Use the box below to post a new question about this Haier product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Haier Manuals

Find free Haier AU48NAIEAA manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Haier Reviews

View thousands of Haier user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Haier customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Haier customer service rankings, employee comments and much more from our sister site.

Haier Recalls

Find comprehensive Haier recall information updated hourly on RecallOwl.com.