Get support for Haier AU282XHERA

Haier AU282XHERA Support Question

Haier AU282XHERA Support Question

Find answers below for this question about Haier AU282XHERA.
Need a Haier AU282XHERA manual? We have 1 online manual for this item!
Question posted by 48maxma on February 5th, 2015

Haier Au282xhera No Communications Error On Outdoor Diagnostic

Haier AU282XHERA no communications error on outdoor diagnostic

Current Answers

Answer #1: Posted by Brainerd on February 5th, 2015 9:56 AM
Brainerd

Member since:
May 24th, 2014

Points: 759,630
90
points


I hope this helps you!
Please press accept to reward my effort or post again with more details if not satisfied.
Regards, Brainerd

Related Haier AU282XHERA Manual Pages

User Manual - Page 1

Please keep this manual carefully before installing the units. R410A MULTI SPLIT SERIES ROOM AIR CONDITIONER OUTDOOR UNIT INSTALLATION MANUAL AU282XHERA AU342XHERA NO.0010577255 A Please read this manual safely for future use.
User Manual - Page 2

Contents Cautions ...1-2 Safety precautions...3-4 Installation accessories 4 Choose the installation place 4 Installation dimensions(mm 4 Installation drawings of indoor and outdoor units 5 Matching of the indoor and outdoor units 6-7 Power source...8 Limitations on the installation 8-9 Refrigerant piping work 10-11 Purging method: to use vacuum pump 12 Wiring work...13-15 Test running......
User Manual - Page 3

...local authorities for any danger to a waste paper disposal service. Unplug the air conditioner in the User's Guide. The manufacturer does not accept responsibility for the ... center and used again after adequate recycling. 1 It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. Always All these valuable materials...
User Manual - Page 4

... user of T 3.15A /250VAC or T 25A/250VAC. Applicable ambient temperature range: Indoor Cooling Outdoor Heating Indoor Outdoor Maximum:D.B/W.B Minimum:D.B/W.B Maximum:D.B Minimum:D.B Maximum:D.B Minimum:D.B Maximum:D.B/W.B Minimum:D.B/W.B 32 C/23 C 18 C/14... to play with the air conditioner. Do not obstruct or cover the ventilation grille of the air conditioner should be carried out ...
User Manual - Page 5

...pipe with insulation materials to use specified accessories and parts. or radio, when installing the communication wire and power supply. (If the radio wave is relatively strong, 1m is not ...down may cause the unit to heat. Arrange wire connection between connecting the indoor and outdoor power supply correctly. Refrigerant will cause water leakage. Improper installation of death or serious ...
User Manual - Page 6

... in the room are not disturbed. Place, possible to drawings). Place,where cold air can be supported sufficiently. In the case of parts Drainage elbow Quantity 1 2 ...the installation place Place, robust not causing vibration, where the body can be connected with the outdoor unit. Installation accessories The following accessories are flammable gas, dirt, and volatile matter (thinner, ...
User Manual - Page 7

...directions Rear left in a level position. Do not connected the embedded branch piping and the outdoor unit when only carrying out piping work without connecting the indoor unit in water leakage or ...fix the unit with foundation bolts, or with the finishing tape from bottom to top. Install the outdoor unit in the insulation pipe's cut line. If the location does not have good drainage, place...
User Manual - Page 8

For AU282XHERA Combination A 07 09 12 1:2 12 14 14... * - * - * - * 07 - 09 - 12 - 14 * 18 * 09 - 12 - 14 * 18 * 09 - 12 * 14 * 18 * 09 * 12 * 14 * 12 * 14 * 12 * Matching of the indoor and outdoor units WARNING! Combinations those marked * would not be applied where the temperature in winter is too low and in summer is too higher to avoid ...
User Manual - Page 9

Matching of the indoor and outdoor units For AU342XHERA Combination A B C D Remark 12 18 - - 1:2 14 14 14 18 - - - 18 18 - - - 07 07 14 - * 07 07 18 - - 07 09 12 - - 07 09 14 - - ...
User Manual - Page 10

...extend the cable by means of refrigerant piping, and the maxmum allowable height difference between all units AU282XHERA AU342XHERA 25m max. 60m max. 8 Connect so that unit will not cause any operating vibration or... possible. Install an exclusive branch circuit of liquid piping between the outdoor and indoor units, are listed below. (The shorter the refrigerant piping, the better the performance...
User Manual - Page 11

...additional refrigerant within this value) m Drop between every two indoor units H + m Drop between the outdoor unit and the indoor unit Standard 6.35 9.52 10 10 10 10 40 1 5 5 Maximum / .../ 25 25 25 25 60 5 15 10 9 m Drop between the outdoor unit and the indoor unit H - Limitations values on the installation 3. Limitations on the piping work . L1 A L2...
User Manual - Page 13

In case that drainage is carried out serely to outdoor. Less than 5cm It becomes high midway. The end is carried out. A Pipe diameter* Liquid side 6.35mm(1/4") Flare tooling die Gas side 9.52mm(3/8") Size A (mm) 0.8~1.5 1.0~1.5 ...
User Manual - Page 14

...moves back in the vacuum pump. In case of gas leakage, tighten parts of the air conditioner leaks, it is necessary to and an angle of charge hose (low) for gaugemanifold. ... and make all the refrigerant out. Vacuumize first, then charge the liquid refrigerant into air conditioner according to ensure a completely vacuum for gaugemanifold into the projection of anticlockwise 90 degree....
User Manual - Page 15

...keep a proper distance between the power line and communication wire to the terminal block and fasten screw. Power... to avoid twist together. Connect the neutral wire with the outdoor unit wiring diagram.) Please check the circuit diagram about the ..., it is damaged, in national standard. Electric wiring Note: The air conditioner must be shielded. If the power line is firmly held. Wiring...
User Manual - Page 16

...,the wire must be grounded on the protection coat of disturbance. Wiring method of outdoor unit: Power line Remove the repair board of indoor unit to the terminal correspondingly... wire end. Incorrect connection will affect protection. Communication wire of air conditioner or the unit can not operate. 3. Note: Power line and communication wire are provided by wire cover. Improper contact...
User Manual - Page 17

...Indoor unit C Indoor unit B Indoor unit A 1(L) 2(N) PQ 1(L) 2(N) C1 C2 1(L) 2(N) 34 1(L) 2(N) 34 Power supply cable: H05RN-F 3G (5.0~8.0)mm2 C1 C2 (P) (Q) L N Communication cable (Shield wire): H05RN-F 2 X (0.75~1.5)mm2 Connecting cable: H05RN-F 3G (1.5~2.5)mm2 30A Outdoor unit 1PH, 220-230V~, 50Hz Please refer to the indoor unit installation manual to find detailly how to the...
User Manual - Page 18

...not start again for test run, put mark " in ". Check the voltage supplied to the outdoor and indoor units, please cinfirm that all indoor units. 4) After ruuning the unit for about 3... 7) Operate the unit according to the operation manual. Heat insulation treatment of indoor and outdoor firmly fixed? Is drainage securely arranged? Does room temperature regulator operate normally? 16 Is ...
User Manual - Page 19

... blocked 14 Over hot protection of SPDU Ambient tempreatrue too high, or outdoor fan be (or ISPM) blocked, or bad air circulation of outdoor unit 15 DC fan motor fault Fan is blocked, or the terminal is disconnected from power source Abnormal communication Communication cables broken, or not be well 25 between main PCB and...
User Manual - Page 20

HAIER GROUP Qingdao Haier Air Conditioner Electric Co., Ltd. Address: Haier Garden, Qianwangang Road, Economic Development Zone, Qingdao, Shandong 266555, P.R.China Web Site: http://www.haier.com

Similar Questions

Commercial Cool Air Conditioner Model# Cwh12a
Where can I purchase a new Commercial Cool air conditioner from?
(Posted by williamsshannon984 2 years ago)
Cooling Problem With My Haier Air Conditioner Model # Hpyo8xcm-e .
my air conditioner does emit cool ( cold ) air BUT it doesn't evenly cool my room ( it's a medium to...
(Posted by leealvarez2 3 years ago)
Air Conditioner Wont Turn On. It Worked Just Fine Two Days Ago
I have a Haeir air conditioner HPAC9M two days ago it worked fine but now it wont turn on
(Posted by alexisiam 3 years ago)
Portable Air Conditioner Keeps Shutting Off
my portable air conditioner keeps shutting down after running for about 10 min
(Posted by Buttercup2 6 years ago)
Haier Esa412r Air Conditioner Bd Noise Rating
what is the db noise rating for the haier esa412r window air conditioner ar various fan speeds
(Posted by Wfrooney 7 years ago)
Ask a New Question
Use the box below to post a new question about this Haier product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Haier Manuals

Find free Haier AU282XHERA manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Haier Reviews

View thousands of Haier user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Haier customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Haier customer service rankings, employee comments and much more from our sister site.

Haier Recalls

Find comprehensive Haier recall information updated hourly on RecallOwl.com.