Question posted by mannyc51 on January 3rd, 2013

Pilot Light No Air Combustion

pilot light, lights.... when turning on thermostat, lights up for 1 second then turns off...

Current Answers

Answer #1: Posted by nbconley1 on February 16th, 2014 10:38 PM
nbconley1

Member since:
February 16th, 2014

Points: 0
100
points
Try replacing the thermostat and make sure that there is no carbon build up on the tip of the pilot orifice. A light buf w/some sandpaper will clean the tip up.

Related GE GG40T06AVG Manual Pages

Use and Care Manual - Page 1

... for future reference. ! FOR YOUR SAFETY! - Do not destroy this symbol as an indication of the water heater; WARNING: If the information in your building. ● Immediately call the fire department. ● Do not return to light any appliance. ● Do not touch any terms within it was purchased. WHAT TO DO IF...
Use and Care Manual - Page 2

... and return the Consumer Product Registration Card that can find them on a label on your water heater. FOR YOUR RECORDS Write the model and serial numbers here: # # You can kill ...Heat Traps 13 Installation Checklist 14 Potable/Space Heating . . . . . 15 Operating Instructions Lighting Instructions 16 Water Temperature. . . . . . 17, 18 Care and Cleaning Draining 19 Maintenance 19 Burner ...
Use and Care Manual - Page 3

... NOT handle, use or store gasoline or other flammable or combustible materials anywhere near or in the vicinity of this or any questions, STOP, and get help from carbon monoxide, never operate this water heater unless it is properly vented and has an adequate air supply for proper operation. It may save you have...
Use and Care Manual - Page 4

..., or elderly persons may be considered when selecting the water temperature setting of the thermostat. Troubleshooting Tips Customer Service Be sure to be used as a guide in determining the proper water temperature for reducing point of the water in branch water lines. Feel water before the water heater was set 120°F at the left details the approximate...
Use and Care Manual - Page 5

... and a qualified agency has determined the area to be safe. ● Before attempting to light the water heater, make sure to look and smell for ventilation and contact the gas supplier, a qualified service...fuel type not in detecting a gas leak. Bubbling at a connection indicates a leak that more than air and will not function safely on LP gas and vice versa. ● No attempt should not ...
Use and Care Manual - Page 7

... in an alcove or closet, the entire floor must be purchased from the store where the water heater was purchased, or any obstruction. If the water heater must not restrict air flow to comply with these combustion air inlet openings and any water it is required between these instructions, local codes, utility company requirements, and/or in unprotected...
Use and Care Manual - Page 8

... 50 cubic feet per 2000 Btuh of the total input rating of all the appliances in determining the size of the water heater requires air for combustion and ventilation air must have the combustion and ventilation air supplied from outdoors, directly or through a flame. Propellants from common spray cans or gas leaks from the ceiling. NOTICE: If...
Use and Care Manual - Page 9

... valve exists in the water heater and piping system can cause what is referred to as "thermal expansion". Check with an air cushion built in the cold water line as a separate back flow preventer, or it to as the system pressure increases, thereby relieving the over these instructions. It may Thermostatic gas valve vary from...
Use and Care Manual - Page 10

.... No valve of any type should be full of the relief valve must remain in the cold water supply line. This condition is turned on the burner can form on the water heater. Condensation might also occur with water. A steady flow of Limited Warranty for the purpose on the tank when it is closed, then...
Use and Care Manual - Page 12

... or larger, never smaller. CAUTION: If local codes require the application of the water heater or the area where the combustion air inlet openings are not necessary. DANGER: Failure to install the draft hood and properly vent the water heater to relocate them on gas water heaters are located. Consult the Vent Tables in unsafe operation of the...
Use and Care Manual - Page 13

... be sealed utilizing a gasket and tamper resistant screws. ■ DON'T block or restrict Combustion Air Inlet Openings located around the lower portion of the water heater is within the range specified on the rating plate. ■ DO provide adequate air for combustion and ventilation as specified on the rating plate. ■ DO ensure that has been...
Use and Care Manual - Page 14

clear of the base of the heater. ■ Clearances from combustion air inlet openings observed (see page 7). ■ Soap and water solution used . Water Supply ■ Water heater completely filled with screws. ■ Single wall vent connector(s) at least 6" from water heater and piping. ■ Water connections tight and free of length minimum). ■ Provisions made to protect ...
Use and Care Manual - Page 15

... instructions for Combination Potable/Space Heating Installation Spring loaded check valve in heating unit hot water supply line and cold water return line (not supplied with water heater) Heating unit Care and Cleaning Troubleshooting Tips Customer Service Combustion Air Inlet Openings 6" air gap 15 This ensures that have previously been used for vertical or horizontal supply lines...
Use and Care Manual - Page 16

Operating Instructions Installation Instructions Safety Instructions Lighting the water heater. (With SmartWater™ Ignition System) Before operating this water heater, be sure to do so can result in unsafe operation of the water heater resulting in property damage, personal injury, or death. Failure to read and follow the instructions on the label pictured below and all other labels...
Use and Care Manual - Page 17

... located on the front of the gas control (thermostat). Do Not turn off manual gas shut-off valve if water heater has been subjected to over heating, fire, flood, physical damage or if the gas supply fails to shut off including their pilot burners, to the hot water system. If such flammables must be opened for...
Use and Care Manual - Page 18

... control system which has been under water. Therefore, always remember to the burner if the water heater exceeds normal operating temperatures. The gas control (thermostat) is constructed with your dealer. ! Red Button Gas cock knob 130°F 140°F 150°F 160°F WARNING READ ALL INSTRUCTIONS BEFORE LIGHTING WAR UTION HOT CA EA S ES...
Use and Care Manual - Page 19

... the tank. This water heater incorporates a combustion shut off before draining water. ! can act as a setling basin for inspection and replaced when more than the gas control (thermostat) dial setting. The water drained from service. At least once a year, lift and release the lever handle on how to create a scald hazard. It is turned off device that...
Use and Care Manual - Page 20

... should be used on the burner and floor shield inside the water heater. Operating Instructions Installation Instructions Safety Instructions Care and cleaning of a match or candle or smoke. Test for an extended period of the flue way. The burner can be turned off until qualified service assistance can produce a hydrogen sulfide, or rotten...
Use and Care Manual - Page 21

.... ● See the "Lighting The Water Heater" section of the water heater down if undesirable combustion conditions occur. Scale on the tank surface. Combustion Shutoff Device Tripped. Excessive condensation can cause pilot outage. ● Use a water heater size that shuts the operation of this manual. ● The connection at the gas control (thermostat) should be tightened by...
Use and Care Manual - Page 22

... service technician. ● See the "Water Temperature Setting of The Water Heater" section of the water heater. Leaking or open hot water faucets. Defective Combustion Shutoff System tripped. Care and Cleaning Troubleshooting Tips Customer Service 22 Combustion Shutoff System tripped. What To Do ● Clean tank. ● This is too hot Pilot Lights, but Burner will not stay lit...

Similar Questions

What Is The Part Number For The Anode Rod For The Ge Water Heater: Model # Pe50
What is the part number for the anode rod for the GE water heater: Model # PE50M09AAH - SERIAL # GE1...
(Posted by dries13644 4 years ago)
Water Heater Is Out
The gas is good to the water heater bu it will not start.
(Posted by dglover 8 years ago)
Gas Valve
where can i purchase a gas valve for this ge water heater
(Posted by Lriverwolf 11 years ago)
Ask a New Question
Use the box below to post a new question about this GE product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

GE Manuals

Find free GE GG40T06AVG manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

GE Reviews

View thousands of GE user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete GE customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed GE customer service rankings, employee comments and much more from our sister site.

GE Recalls

Find comprehensive GE recall information updated hourly on RecallOwl.com.