Frigidaire FRA052XT7 Support Question
Find answers below for this question about Frigidaire FRA052XT7.Need a Frigidaire FRA052XT7 manual? We have 5 online manuals for this item!
Question posted by spiritsmom2003 on June 23rd, 2013
Frigidaire Humidifier Model Fdl 7051 Water Bucket No Longer Filling Up.
The humidifer is still runs and is cooling the area but no water is accumulating in the bucket.
Current Answers
Answer #1: Posted by OnlineOutreachSpecialist on June 27th, 2013 5:58 AM
Hello spiritsmom2003 - Often when a dehumidifier is not collecting water, it is because there is either low humidity in the room or possible sealed system issues. The unit is similar to a refrigerator. It has an evaporator and the air is pulled across it. When the moist air is pulled across the evaporator, the water droplets in the air are condensed back to liquid form and that is when it begins to build water. So, more than likely the compressor is not running or there is a leak in the sealed system not allowing the evaporator to get cold enough to remove moisture from the air. In some cases depending in where the unit is located, sometimes there is no moisture in the air. Because it is a smaller appliance, repairs are often more costly than the actual unit replacement. You may want to check and see if your dehumidifier is still under warranty and if so, reach out to the manufacturer to determine the exact warranty coverage. Thanks for allowing me to help you.
Online Outreach Specialist
Related Frigidaire FRA052XT7 Manual Pages
Similar Questions
Power Cord Reset Board Burnt, Can I Replace Using Any Other Cord?
Power cord prong loose, causing power cord to reset. I have an old aircon unit, can I use the power ...
Power cord prong loose, causing power cord to reset. I have an old aircon unit, can I use the power ...
(Posted by delacruzjoannrose 7 years ago)
Ffrh1822q2.model Number For Wall Unit For Ac / Heat.how Many Psi Of Freon To Put
need to know how many pounds of freon or how much pressure of freon for 410a that needs to go in the...
need to know how many pounds of freon or how much pressure of freon for 410a that needs to go in the...
(Posted by drpcs77 9 years ago)
Frigidaire Air Conditioner Model Fra054xt7 Where Does The Water Drip
(Posted by pcmardmc12 10 years ago)
My Fridigairie Air Conditioner Model Number Fra 186mt2 Will Not Come On.
when i plug the power cord into outlet the display board lights up for 5 seconds and then goes off w...
when i plug the power cord into outlet the display board lights up for 5 seconds and then goes off w...
(Posted by robertsondwan8 10 years ago)
Drain System For Ac Fac12p1a
do u have a peice to conect to the hole where the water comes out from
do u have a peice to conect to the hole where the water comes out from
(Posted by yisroelmayteles 10 years ago)