Question posted by vinpierce on February 18th, 2017

Cal Err.

Fluke 87V only showing Cal err. When just checking into calibration data count, it is showing n000.How does it lost it calibration dada count from ROM?Should it at least has an n001 in the memory bank? How I can recall or reset this meter to the factory state?

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Fluke 87V Manual Pages

FE 83V & 87V Users Manual - Page 1

All product names are trademarks of their respective companies. Users Manual ® 80 Series V Multimeters May 2004 Rev. 1, 8/04 2004 Fluke Corporation, All rights reserved.
FE 83V & 87V Users Manual - Page 2

... risk for damage in one country is defective, contact your product on then current component acquisition costs. FLUKE SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, ARISING FROM ANY CAUSE OR THEORY. This warranty covers the original purchaser only and is held...
FE 83V & 87V Users Manual - Page 3

Table of Contents Title Page Introduction...1 Contacting Fluke ...1 Safety Information ...2 The Meter's Features ...6 Power-Up Options ...13 Automatic Power-Off ...13 Input Alert Feature ...13 Making Measurements...13 Measuring AC and DC ...
FE 83V & 87V Users Manual - Page 5

Rotary Switch Positions...7 4. Functions and Trigger Levels for Frequency Measurements 28 7. Accessories ...42 10. Temperature Specifications (87 Only 47 14. List of the Terminals 51 19. MIN MAX Functions...33 8. Pushbuttons...8 5. Model 87 AC Voltage Function Specifications ...
FE 83V & 87V Users Manual - Page 9

... (hereafter referred to as "the Meter"). Except where noted, the descriptions and instructions in the world: +1-425-446-5500 For USA Service: 1-888-99-FLUKE (1-888-993-5853) Or, visit Fluke's Web site at www.fluke.com. Introduction XWWarning Read "Safety Information" before you use the Meter. Model 87 appears in all illustrations.
FE 83V & 87V Users Manual - Page 16

.... Starts recording of minimum and maximum values. To return to autoranging, hold for 1 second) Enables the Meter's calibration mode and prompts for the selected function. The Meter reads "5___" until A is released. 8 The Meter reads...Switches between °C and °F. The Meter reads "CAL" and enters calibration mode. 80 Series V Users Manual Button A (Yellow) B C Table 4.
FE 83V & 87V Users Manual - Page 19

... is 250 µs (87 only). A Trig Positive or negative slope indicator for the analog bar graph. Number Feature Indication E - Indicates negative readings. Also appears in cal, Hz, and duty cycle modes. Also appears in low pass filter mode. H S Display Hold is active. m Indicators for minimum-maximum J MAX recording mode. MIN AVG...
FE 83V & 87V Users Manual - Page 20

... the left of the graph indicates the polarity of segments is relative to the terminal being tested. Invalid calibration data. WTest lead alert. The polarity indicator at the left . The Meter is in manual range mode. ... resolution (Hi Res) mode. bAtt diSC EEPr Err CAL Err LEAd Feature 0L Indication The number of the input. Error Messages Replace the battery immediately.
FE 83V & 87V Users Manual - Page 37

... the lowest range that does not result in automobiles, use the 6 V dc range. Systems such as electronic fuel injection systems and switching power supplies are controlled by pulses of varying width, which can be checked by pressing E. The duty cycle mode is above or below a trigger level during one cycle (Figure 9). For...
FE 83V & 87V Users Manual - Page 45

...case over. 4. Service and Parts If the Meter fails, check the battery and fuses. Remove the battery door by turning... Reinstall the three screws and the battery door. Replacement parts and accessories are in the OFF position. 8. Replacing the Fuses Referring to ... the input terminal-end of the battery compartment to "Contacting Fluke". 37 Verify that the gasket is properly seated and case...
FE 83V & 87V Users Manual - Page 47

... Battery Door MP27-MP30 Contact RSOB MP31 Mask, LCD (PAD XFER) MP41 Housing, RSOB WTo ensure safety, use exact replacement only. Service and Parts Qty. 1 1 1 1 3 5 2 1 1 1 1 1 1 2 1 1 1 1 4 1 1 Fluke Part or Model Number 2139179 2064217 943121 803293 832246 448456 817460 2073906 2074025 2073992 2073871 2100482 822643 824466 828541 831933 2074033 2073938 1567683 2073950 2073945...
FE 83V & 87V Users Manual - Page 48

... Door Fastener Tiltstand LCD, 4.5 DIGIT,TN, Transflective, Bar Graph, OSPR80 Lightpipe Keypad 80 Series V Multi-Language Getting Started Manual 80 Series V Quick Reference Card CD ROM,80 Series V User Manual Qty. 1 1 1 1 2 1 1 1 1 1 1 1 Fluke Part or Model Number 1670652 1670641 855742 1273113 948609 2074040 2065213 2074057 2105884 2101973 2101986 2101999 40
FE 83V & 87V Users Manual - Page 50

Accessories Item Description AC72 Alligator Clips for use with TL75 test lead set AC220 Safety Grip, Wide-Jaw Alligator Clips TPAK ToolPak ... TL224 Test Lead Set, Heat-Resistant Silicone TP1 Test Probes, Flat Blade, Slim Reach TP4 Test Probes, 4 mm diameter, Slim Reach Fluke accessories are available from an authorized Fluke distributor. 42 80 Series V Users Manual Table 9.
Getting Started Guide - Page 1

All product names are subject to change without notice. ® 80 Series V Multimeters Getting Started Manual PN 2101973 May 2004 Rev.2, 11/08 © 2004, 2008 Fluke Corporation. Printed in U.S.A. Specifications are trademarks of their respective companies. All rights reserved.
Getting Started Guide - Page 2

... by a court or other provision. FLUKE SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, ARISING FROM ANY CAUSE OR THEORY....-warranty. AUTHORIZED RESELLERS ARE NOT AUTHORIZED TO EXTEND ANY DIFFERENT WARRANTY ON FLUKE'S BEHALF. Fluke assumes no charge, replace or refund the purchase price of repair/replacement parts...
Getting Started Guide - Page 3

Table of Contents Title Page Introduction...1 Contacting Fluke ...1 Safety Information ...1 The Meter's Features ...4 Power-Up Options ...11 Automatic Power-Off 11 Input Alert™ Feature 11 Low Pass Filter (87 11 Bar Graph...12 AutoHOLD ® Mode ...13 Relative Mode ...13 Maintenance...13 General Maintenance 13 Fuse Test ...13 Specifications ...14 Detailed Specifications 15 i
Getting Started Guide - Page 7

...-993-5853) Or, visit Fluke's Web site at www.fluke.com. A Caution identifies conditions and actions that pose hazards to the user. Look for damaged insulation or exposed metal. Pay particular attention to as "the Meter"). Check the test leads for continuity. XWWarning To avoid possible electric shock or personal injury, follow these...
Getting Started Guide - Page 12

... MIN, AVG (average), and present readings. To return to autoranging, hold for 1 second. Enables the Meter's calibration mode and prompts for the selected function. Cancels MIN MAX (hold the button down for 1 second). Starts recording ... switch position Power-up Any switch position M Power-up Selects capacitance Table 4. The Meter reads "CAL" and enters calibration mode.
Getting Started Guide - Page 15

... voltage input. Indicates the Meter is in low pass filter mode. TrigY X W g Positive or negative slope indicator for minimum-maximum recording mode. Also appears in cal, Hz, and duty cycle modes. Low pass filter mode (87 only). Display Features Feature Indication Y Polarity indicator for the analog bar graph.
Getting Started Guide - Page 16

Overload condition is detected. bAtt diSC EEPr Err CAL Err LEAd F8/Err OPEn Display Messages Replace the battery immediately. Invalid EEPROM data. Invalid model. In normal operation 0 (zero) is in autorange mode and... charge is relative to the terminal being tested. Have Meter serviced. Invalid calibration data. Calibrate Meter. WTest lead alert. Have Meter serviced.

Similar Questions

Cal Err Message Is Showing While On The Clamp Meter
CAL Err message is showing while power on the clamp meter.No buttons are functioning after this erro...
(Posted by kvramesh 1 year ago)
Fluke 87 Cal Err
I openen my Metter battery cover to change the battery after I change it I found out that is showing...
(Posted by Engrnonsonic3876 6 years ago)
Cal Err
My Metter was on I opened the battery cover to change the battery then after I change it I discovere...
(Posted by Engrnonsonic3876 6 years ago)
My Fluke 87v Cal Error. What Can I Do?
when I turn on the tester a cal err messaje .what can I do?
(Posted by euriosoler123 7 years ago)
Ask a New Question
Use the box below to post a new question about this Fluke product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Fluke Manuals

Find free Fluke 87V manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Fluke Reviews

View thousands of Fluke user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Fluke customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Fluke customer service rankings, employee comments and much more from our sister site.

Fluke Recalls

Find comprehensive Fluke recall information updated hourly on RecallOwl.com.